2317 Cambreleng Avenue
Bronx, NY 10458BBL 2-03088-0039
2317 Cambreleng Avenue is a property in Bronx, 10458. HPD has recorded 132 housing violations here, most recently on October 29, 2026. 5 of the 50 most recent violations are still open. City tax records listed 50 rent-stabilized apartments here in 2024.
- HPD violations
- 132
- DOB violations
- 7
- ECB violations
- 19
- HPD complaints
- 307
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. The newest 10 per agency here; the full lists are a click away.
HPD housing violations · 132
- BHazardous
Properly repair or replace the broken or defective intercom system panel at east wall in the foyer located at apt 5e, 5th story, 5th apartment from south at west
Oct 29, 2026 · Apt 5E
Open — Violation open - BHazardous
Properly repair or replace the broken or defective handle at vestibule door at public hall, 1st story
Sep 14, 2026
Open — Nov certified on time - BHazardous
Properly repair or replace the broken or defective bell buzzer intercom system from the building entrance door to the apartment wall panel in the entire apartment located at apt 5e, 5th story, 5th apartment from east at south
Sep 10, 2026 · Apt 5E
Open — Nov certified on time - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at building entrance and vestibule at public hall, 1st story
Sep 9, 2026
Open — Not complied with - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at building vestibule door at public hall, 1st story
Jul 23, 2026
Open — Not complied with - ANon-hazardous
File with this department a registration statement for building.
Jul 23, 2026
Closed — Violation dismissed - CImmediately hazardous
Provide ready access to buildings heating system locked door at boiler room
Mar 27, 2026
Closed — Violation dismissed - CImmediately hazardous
Provide hot water at all hot water fixtures in the entire apartment located at apt 4b, 4th story, 2nd apartment from south at west , section ''abi'', at south
Mar 27, 2026 · Apt 4B
Closed — Violation dismissed - CImmediately hazardous
Provide ready access to buildings heating system locked door at boiler room
Mar 24, 2026
Closed — Violation dismissed - CImmediately hazardous
Provide hot water at all hot water fixtures in the entire apartment located at apt 4b, 4th story, 2nd apartment from south at west
Mar 24, 2026 · Apt 4B
Closed — Violation dismissed
DOB building violations · 7
- Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 27, 2019
Dob violation - dismissed - Construction other optional
C-construction other optional
Feb 8, 2019
Vp*-violation unserved ecb- dismissed
ECB violations · 19
- Class - 2
Failure to maintain building exterior facade and appurtenances. note: at time of inspection, i observed at exp #2 south, #3 west, #4 north cracked/spalling mortar joints multi loc.-exp #3 west has missing copin
Oct 25, 2024 · Penalty $1,250
Active - Class - 1
At the time of inspection, observed 8 story occupied mixed use building with ongoing construction work on 1st and 2nd floor. tenant protection plan was not provided nor posted anywhere in the building. g.c fai
May 17, 2023 · Penalty $1,250
Resolve - Class - 2
Work does not conform to approved const documents and/or amendments-sodewalk shed @time of inspection @a 8 sty nb, i observed on street/ground lvl sidealk shed bridge was not built to plans & also braces
May 11, 2020 · Penalty $625
Resolve - Class - 2
Failure to institute safe measures at a construction or demolition site.at time of inspection at an active new building construction jobsitei observed an open elevator shaft at bulkhead that had no guardrails o
Apr 8, 2020 · Penalty $5,000
Resolve - Class - 1
Unsafe storage of combustible materials & equipment @time of inspection i observed combustibel materials (sperated all floors. more than 25 cu. yard. in each floor. which is weight/falls/trip hazards. cutting
Dec 7, 2019 · Penalty $625
Resolve - Class - 1
Failure to maintain housekeeping per section requirement. @time of inspection i observed const materials (seperated) all floors. it is more than 25 cu. yard each floor. which one hazardous. thses debris/matel
Dec 7, 2019 · Penalty $625
Resolve - Class - 1
Failure to safeguard all persons & property affected by const operations. @time of inspection i obseved. workers doing work w/o guardrail(onthe roof), w/o wearing fall protection, & observed no caps on rebar.
Dec 7, 2019 · Penalty $5,000
Resolve - Class - 2
Works contrary to after hours variance permit. @the time of inspectioni observed works performed w/o ahv permit/contrary to 28-105.12.5 rem:obtain permit.
Dec 7, 2019 · Penalty $625
Resolve - Class - 2
Construction superintendent failed to perform duties per code.@time ofinsp of an 8story bldg @roof level const work in progress.during insp noted several violation conditions:1-const chute w/o permit 2-no overh
Aug 26, 2019 · Penalty $2,500
Resolve - Class - 2
3301.1.3contractors shed not fire peterdant treated.@time of insp of 8story bldg @roof level const work in progress.during insp noted that the temp office located @1st fl & the wall was built w/plywood & wood
Aug 26, 2019
Resolve
Complaints
- General
Bell/buzzer/intercom
Oct 21, 2026 · Apt 5E
Close - Door/window
Door
Oct 21, 2026 · Apt 5E
Close - Door/window
Door frame
Oct 5, 2026 · Apt BUILDI
Close - Electric
Outlet/switch
Sep 3, 2026 · Apt 7I
Close - Paint/plaster
Ceiling
Sep 3, 2026 · Apt 7I
Close - Paint/plaster
Ceiling
Sep 3, 2026 · Apt 7I
Close - Unsanitary condition
Mold
Sep 3, 2026 · Apt 7I
Close - Appliance
Electric/gas range
Aug 6, 2026 · Apt 8E
Close - Door/window
Door
Jul 23, 2026 · Apt 4B
Close - General
Bell/buzzer/intercom
Jul 8, 2026 · Apt 5E
Close
Sales history
No recorded sales in our data
Building details
- Building type
- —
- Year built
- —
- Floors
- —
- Residential units
- —
- Building area
- —
- Lot area
- —
- Zoning
- —
- Community board
- —
- Council district
- —
- Block / lot
- 3088 / 39
- Assessed value
- —
- Landmark / historic district
- No
HPD registration #228271, last renewed Aug 29, 2026.
Questions about 2317 Cambreleng Avenue
Does 2317 Cambreleng Avenue have violations?
Yes. NYC HPD has recorded 132 housing violations at this property.
Is 2317 Cambreleng Avenue rent stabilized?
NYC Department of Finance tax bills listed 50 rent-stabilized units here in 2024. To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.