1056 Sheridan Avenue
Bronx, NY 10456BBL 2-02456-0036Map
Owner of record: Sheridan Avenue Properties LLC
1056 Sheridan Avenue is a walk-up apartment building built in 1918 in Bronx, 10456. It has 16 residential units across 5 floors. The owner of record is Sheridan Avenue Properties LLC. HPD has recorded 49 housing violations here, most recently on April 29, 2026. 27 of the 49 most recent violations are still open. City tax records listed 16 rent-stabilized apartments here in 2024.
- HPD violations
- 49
- DOB violations
- 7
- ECB violations
- 1
- HPD complaints
- 115
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 49
- CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch set at building entrance door , 1st story
Apr 29, 2026
Closed — Violation closed - BHazardous
Properly repair or replace the broken or defective latch set at building entrance door , 1st story
Apr 29, 2026
Closed — Violation closed - BHazardous
Repair the leaky and/or defective faucets at sink in the kitchenette located at apt 3a, 3rd story, 1st apartment from north at east
Mar 31, 2026 · Apt 3A
Closed — Violation closed - BHazardous
Properly repair or replace the broken or defective spring balance upper sash at second window from east at south in the 2nd room from east at south located at apt 3a, 3rd story, 1st apartment from north at east
Mar 31, 2026 · Apt 3A
Closed — Violation closed - BHazardous
Abate the infestation consisting of bedbugs in the entire apartment located at apt 3a, 3rd story, 1st apartment from north at east
Mar 31, 2026 · Apt 3A
Closed — Violation closed - BHazardous
Properly repair or replace the broken or defective dry rotted cabinet base at sink in the kitchenette located at apt 3a, 3rd story, 1st apartment from north at east
Mar 31, 2026 · Apt 3A
Closed — Violation closed - BHazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the 3rd bathroom from east located at apt 3a, 3rd story, 1st apartment from north at east
Mar 31, 2026 · Apt 3A
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch set at building entrance door , 1st story
Mar 12, 2026
Closed — Violation closed - BHazardous
Properly repair or replace the broken or defective latch set at building entrance door. , 1st story
Mar 12, 2026
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective spring balance at lower sash at 1st window from north at east in the 4th room from east at north located at apt 3a, 3rd story, 1st apartment from north at east
Mar 12, 2026 · Apt 3A
Open — Nov sent out
Show 39 more ↓
- BHazardous
Properly repair or replace the broken or defective spring balance at upper sash at 4th window from east at south in the 2nd room from east at south located at apt 3a, 3rd story, 1st apartment from north at east
Mar 12, 2026 · Apt 3A
Open — Nov sent out - BHazardous
Refit building entrance door
Mar 11, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair or replace the broken or defective lock assmbely at entrance to building , 1st story
Sep 21, 2025
Open — Nov sent out - CImmediately hazardous
Fire escape defective. replace with new the broken, defective and/or missing the 2nd metal batten from north at balcony at building front. at 2nd fire escape from east, 2nd story
Sep 13, 2025
Open — Not complied with - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Jun 5, 2025
Closed — Violation dismissed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective door frame at building entrance [from street to public hall] , 1st story
Mar 12, 2025
Closed — Violation closed - CImmediately hazardous
Provide ready access to buildings heating system door locked at boiler room
Mar 12, 2025
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective porcelain enamel finish by method of reglazing at bathtub in the bathroom located at apt 2c, 2nd story, 1st apartment from south at west
Mar 12, 2025 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Properly repair or replace the broken or defective heavy duty mortise lock and assembly at building entrance door [from street to public hall] , 1st story
Mar 12, 2025
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 2c, 2nd story, 1st apartment from south at west
Mar 12, 2025 · Apt 2C
Open — Nov sent out - BHazardous
M/d law abate the nuisance consisting of lockable knob installed at door leading to fire escape window in the 4th room from east at south located at apt 2c, 2nd story, 1st apartment from south at west
Mar 12, 2025 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Provide hot water at all hot water fixtures in the entire apartment located at apt 2c, 2nd story, 1st apartment from south at west
Mar 12, 2025 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Provide hot water at all hot water fixtures in the 1st room from east at north located at apt 1a, 1st story, 1st apartment from north at east
Dec 27, 2024 · Apt 1A
Open — Nov sent out - CImmediately hazardous
Provide ready access to buildings heating system door locked at boiler room
Dec 27, 2024
Open — Nov sent out - CImmediately hazardous
Properly repair or replace the broken or defective heavy duty mortise lock assembly at building entrance door [from street to public hall] , 1st story
Dec 18, 2024
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective door frame leading to north yard at public hall, 1st story
Dec 18, 2024
Open — Nov sent out - CImmediately hazardous
Provide hot water at all hot water fixtures in the entire apartment located at apt 1a, 1st story, 1st apartment from north at east
Dec 11, 2024 · Apt 1A
Closed — Violation closed - ANon-hazardous
Properly repair or replace the broken or defective light fitxure (e-1) at ceiling in the private hallway located at apt 1a, 1st story, 1st apartment from north at east
Dec 11, 2024 · Apt 1A
Open — Nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 22, 2024
Closed — Violation dismissed - BHazardous
Provide adequate supply of hot water for the fixtures at bathtub in the bathroom located at apt 3b, 3rd story, 1st apartment from east at south
Apr 10, 2024 · Apt 3B
Open — Invalid certification - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 3, 2022
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 4a, 4th story, 1st apartment from north at east
Oct 26, 2022 · Apt 4A
Open — Nov certified late - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 4a, 4th story, 1st apartment from north at east
Oct 26, 2022 · Apt 4A
Open — Nov certified late - BHazardous
Properly repair the broken or defective window counter balance at lower sash at south pane in the 2nd room from east at south located at apt 4a, 4th story, 1st apartment from north at east
Oct 26, 2022 · Apt 4A
Open — Invalid certification - CImmediately hazardous
Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 3; wg to replace = 0; wg to repair = 1; in the entire apartment located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Closed — Violation dismissed - BHazardous
Repair or replace the smoke detector inoperative in the entire apartment located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Closed — Violation dismissed - BHazardous
Repair or replace the carbon monoxide detecting device(s). inoperative in the entire apartment located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Open — Nov certified late - BHazardous
M/d law abate the nuisance consisting of key-operated lock on door leading to the fire escape window in the 1st room from east at north located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Open — Nov certified late - BHazardous
Fire egress defective. remove obstructing bars or unlawful gates from window to fire escape or provide approved type gate ...(chain and padlock at gate installed at window tofire escape) in the 1st room from east at north located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Open — Nov certified late - CImmediately hazardous
Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from south at west wall in the foyer located at apt 3a, 3rd story, 1st apartment from north at east
Feb 2, 2022 · Apt 3A
Open — Nov sent out - CImmediately hazardous
Provide an adequate supply of heat for the apartment in the entire apartment located at apt 1a, 1st story, 1st apartment from north at east
Dec 19, 2019 · Apt 1A
Closed — Violation closed - CImmediately hazardous
Provide hot water at all hot water fixtures in the entire apartment located at apt 1a, 1st story, 1st apartment from north at east
Dec 19, 2019 · Apt 1A
Open — Nov sent out - CImmediately hazardous
Provide ready access to buildings heating system no access to boiler room
Dec 19, 2019
Open — Nov sent out - BHazardous
Provide adequate supply of hot water for the fixtures at water closet in the bathroom located at apt 3a, 3rd story, 1st apartment from north at east
Nov 16, 2012 · Apt 3A
Closed — Violation dismissed - BHazardous
Provide an acceptable heavy lock and latch set at entrance door to building
Nov 16, 2011
Closed — Violation closed - CImmediately hazardous
Remove the illegal fastening unacceptable electromagnetic locking device installed at entrance door to building
Nov 16, 2011
Closed — Violation closed - BHazardous
Remove all encumbrances consisting of bicycles locked to stair rail preventing access to door leading to rear yard at north wall. at public hall, 1st story
Oct 3, 2011
Closed — Violation closed - BHazardous
Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment located at apt 1b, 1st story, 1st apartment from east at south
Sep 9, 2009 · Apt 1B
Closed — Violation closed - CImmediately hazardous
Repair the broken or defective plastered surfaces and paint in a uniform color ceiling 1st sty southwest apt 1b center room er1. , section '' ''
Jun 10, 1999 · Apt 1B
Closed — Violation closed
DOB building violations · 7
- Elevator elevatorrequired
E-elevator elevatorrequired
Nov 14, 2006
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 17, 1993
Dob violation - dismissed
ECB violations · 1
- Class - 1
Apprx. twenty of lf retaining wall collapsed at exposure#3., repair and/replace
Jun 28, 2023 · Penalty $1,250
Active
Complaints
- Door/window
Door
Sep 17, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Apr 29, 2026 · Apt BLDG
Close - Flooring/stairs
Floor
Mar 27, 2026 · Apt 3A
Close - General
Cabinet
Mar 27, 2026 · Apt 3A
Close - Paint/plaster
Wall
Mar 27, 2026 · Apt 3A
Close - Unsanitary condition
Pests
Mar 27, 2026 · Apt 3A
Close - Heat/hot water
Entire building
Mar 11, 2026 · Apt BLDG
Close - Unsanitary condition
Pests
Mar 5, 2026 · Apt 3A
Close - Water leak
Slow leak
Mar 5, 2026 · Apt 3A
Close - Door/window
Window frame
Mar 5, 2026 · Apt 3A
Close
Show 40 more ↓
- Door/window
Window pane
Mar 5, 2026 · Apt 3A
Close - Heat/hot water
Entire building
Feb 17, 2026 · Apt BLDG
Close - Unsanitary condition
Pests
Feb 4, 2026 · Apt 3A
Close - Appliance
Refrigerator
Feb 4, 2026 · Apt 3A
Close - Heat/hot water
Apartment only
Feb 4, 2026 · Apt 3A
Close - Unsanitary condition
Pests
Feb 4, 2026 · Apt 3A
Close - Paint/plaster
Wall
Feb 4, 2026 · Apt 3A
Close - Unsanitary condition
Mold
Feb 4, 2026 · Apt 3A
Close - Safety
Carbon monoxide detector
Feb 4, 2026 · Apt 3A
Close - Safety
Smoke detector
Feb 4, 2026 · Apt 3A
Close - Water leak
Slow leak
Feb 4, 2026 · Apt 3A
Close - Door/window
Window frame
Feb 4, 2026 · Apt 3A
Close - Heat/hot water
Apartment only
Jan 19, 2026 · Apt 2D
Close - Heat/hot water
Entire building
Jan 14, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 13, 2026 · Apt BLDG
Close - Heat/hot water
Apartment only
Jan 11, 2026 · Apt 5C
Close - Plumbing
Water supply
Jan 9, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 7, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 6, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 5, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Nov 27, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Nov 26, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Nov 20, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 31, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 26, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 12, 2025 · Apt BLDG
Close - Heat/hot water
Apartment only
Feb 17, 2025 · Apt 2B
Close - Heat/hot water
Entire building
Dec 27, 2024 · Apt BLDG
Close - Heat/hot water
Entire building
Dec 24, 2024 · Apt 3AENTI
Close - Heat/hot water
Entire building
Dec 23, 2024 · Apt 1A
Close - Heat/hot water
Entire building
Dec 17, 2024 · Apt BLDG
Close - Heat/hot water
Entire building
Dec 9, 2024 · Apt 3A
Close - Heat/hot water
Entire building
Apr 10, 2024 · Apt 3B
Close - Appliance
Refrigerator
Apr 17, 2023 · Apt 1A
Close - Appliance
Electric/gas range
Oct 12, 2022 · Apt 4A
Close - Plumbing
Basin/sink
Oct 12, 2022 · Apt 4A
Close - Flooring/stairs
Floor
Oct 12, 2022 · Apt 4A
Close - Door/window
Window frame
Oct 12, 2022 · Apt 4A
Close - Door/window
Window frame
Oct 12, 2022 · Apt 4A
Close - Unsanitary condition
Pests
Oct 10, 2022 · Apt 1F
Close
Sales history
| Date | Price | Type | Units |
|---|---|---|---|
| Dec 23, 2025 | $1,111,500 | Rentals - walkup apartments | 16 |
Building details
- Building type
- Walk-up apartment building (C1)
- Year built
- 1918
- Floors
- 5
- Residential units
- 16
- Building area
- 17,600 ft²
- Lot area
- 4,000 ft²
- Zoning
- R7-1
- Community board
- 204
- Council district
- 16
- Block / lot
- 2456 / 36
- Assessed value
- $299,250
- Landmark / historic district
- No
HPD registration #209555, last renewed Jan 16, 2026.
Questions about 1056 Sheridan Avenue
Who owns 1056 Sheridan Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Sheridan Avenue Properties LLC.
Does 1056 Sheridan Avenue have violations?
Yes. NYC HPD has recorded 49 housing violations at this property.
Is 1056 Sheridan Avenue rent stabilized?
NYC Department of Finance tax bills listed 16 rent-stabilized units here in 2024 (about 100% of its 16 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 1056 Sheridan Avenue built?
City records list 1918 as the year it was built.
How many apartments are in 1056 Sheridan Avenue?
It has 16 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.