11 Riverside Drive
Manhattan, NY 10023BBL 1-01184-0031Map
Owner of record: Eleven Riverside Drive Corp
11 Riverside Drive is an elevator apartment building built in 1950 in Manhattan, 10023. It has 636 residential units across 19 floors. The owner of record is Eleven Riverside Drive Corp. HPD has recorded 5 housing violations here, most recently on March 15, 2023. City tax records listed 11 rent-stabilized apartments here in 2024.
- HPD violations
- 5
- DOB violations
- 114
- ECB violations
- 45
- HPD complaints
- 18
Available now in this building
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 5
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 15, 2023
Closed — Violation dismissed - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall, 1st story
Feb 1, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 1, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 9, 2018
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 26, 2016
Closed — Violation dismissed
DOB building violations · 114
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 3, 2021
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 16, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 16, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 16, 2019
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2018)
Mar 18, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 31, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 31, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 19, 2018
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)
Mar 27, 2018
Dob violation - dismissed
Show 40 more ↓
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 5, 2017
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2016)
Feb 16, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2016
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years(2015)
Jun 1, 2016
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2014
May 14, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 9, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 9, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 9, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2015
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 1, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 9, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 3, 2013
Dob violation - resolved
ECB violations · 45
- Class - 2
Atoi observed excessive construction debris stored in black bag, significant construction fumes were present from on goin demolition. submitted tpp does not provide information regarding debris disposal procedu
Dec 2, 2025 · Penalty $2,500
Active - Class - 1
Atoi observed in kitchen gas pipe line un capped. (job# m01265748 s1-pl); 406.6.2, comply with code
Dec 2, 2025 · Penalty $2,500
Active - Class - 1
Atoi observed in unit under job # m01265748-gc excessive black bags with construction debris over the allowed amount being stored., maintain adequate construction housekeeping
Dec 2, 2025
Resolve - Class - 2
Active 17 story facade repair jobsite.i observed outrigger beams installed at expos 4 not according to plans. walk through, masonary, & ladder frame setup not on cd5. tiebacks to parapet wall using turnbuckle n
Nov 10, 2022
Resolve - Class - 2
At the time of my inspection of a active 17 story facade repair construction site i observed a c-hook scaffold installed at expos 4. after requesting to see detailed drawings for c-hooks none were provided. ---
Nov 10, 2022
Resolve - Class - 1
At the time of my inspection of a 17 story facade repair jobsite. i observed a worker on a supported scaffold installed on a terrace approx 12' high on the 16th floor with no fall protection system provided (mi
Nov 10, 2022 · Penalty $2,500
Resolve - Class - 2
Failure to post and distribute tenant protection plan.note:at time of inspection observed work being performed in apt 16ew under aforementioned job number with no tpp posted or distributed in occupied building
Oct 29, 2021 · Penalty $3,125
Resolve - Class - 2
Failure to post or distribute safe construction bill of rights.note:at time of inspection observed work being performed under aforementioned job number by code it is required that scbor be posted or distributed
Oct 29, 2021 · Penalty $1,250
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. at time of inspection at the above address on the above date i observed on (2004) fire pump room installed w/gas line & fully operating a hot water heater in
Jun 20, 2018 · Penalty $1,250
Resolve - Class - 1
Fgc 404.1 gas piping and/or appliances installed in prohibited locations. at time of inspection at the above address on the above date i observed on roof level in fire pump room gas piping and gas water heater
Jun 20, 2018
Resolve
Show 35 more ↓
- Class - 1
Gas being supplied to building w/o inspection and certification by thedob. at time of inspection at the above address on the above date i observed on roof in fire pump room gas piping installed feeding a hot wa
Jun 20, 2018
Resolve - Class - 1
Failure to comply obtain permit also failed to comply w/ecb violation #35080040p. remedy: comply w/ec code & obtain an electrical work permit.
Mar 1, 2016 · Penalty $800
Resolve - Class - 1
Electrical work does not conform to approved submittal documents/amendments. bsmt service switches & 475kw generators: no advisory board approveal provided."please note" the existing service equipment are over
Dec 17, 2015 · Penalty $500
Resolve - Class - 1
Electrical work w/o a permit."go generation systems" cellar boiler room & electrical room: 4 set of 400mcm sub feeders,4-400amp disconnects,4-75kd generators. not on file. remedy: obtain permit z123133 does not
Dec 17, 2015 · Penalty $800
Resolve - Class - 1
Sec. 250.24(e) ungrounded system grounding connections. a premises wiring system that is supplied by on pc service that is ungrounded shall have,at each service a grounding electrode(5)required by part iii of
Dec 17, 2015 · Penalty $800
Resolve - Class - 2
Failure to provide approved plans at work site at time of inspection. no plans for job #120994629 at job site at time of inspection. remedy:provide approved plan - contact us at 718-286-0683 for reinspection.
May 16, 2012
Resolve - Class - 1
Sec bc3310.6. failure to have site safety manager/coordinator present as required: upon inspection as noted on active/alt site men working on terraces and around parapet walls penthouse level (19th) as per
Jul 20, 2011
Resolve - Class - 1
Failure to institute maintain safety equipment measures or temporary constructing no guard rails at the time of my insp appx 9 workers on site bldg structural up to 19fl observed a baker supported scaffold was
Oct 7, 2010 · Penalty $1,200
Resolve - Class - 1
Bc3308.3 failure to provide vertical netting as required upon insp as noted on active construction site up to 19th fl the vertical netting was drooping to appx 30" and in other locations it has been completely
Jul 13, 2010 · Penalty $1,600
Resolve - Class - 2
Bc3307.4.3 failure to provide warning lights for vehicular traffic construction site up to 19th fl there were pallets of brick surrounded by barriers on 73 st side of jobsite and no warning lights lanterns were
Jul 13, 2010
Resolve - Class - 2
Failure to provide fire extinguishers upon inps as noted on active construction site up to 19th fl there was an inadequate amount of fire extinguisher on fls 18 & 19 only 1# 151b fire extinguisher was available
Jul 13, 2010
Resolve - Class - 1
Bc3303.4.51 storage of material during construction upon insp as noted on active construction site up to 19th fl there was material placed at the leading edge of the bldg brick plywood metal studs debris laying
Jul 13, 2010 · Penalty $1,600
Resolve - Class - 1
Failure to institute and maintain safety equipment measures or temporary construction no toe boards upon insp as noted on active construction site up to 19th fl there were no toe boards around the spiral stairw
Jul 13, 2010 · Penalty $1,000
Resolve - Class - 1
Failure to safeguard all persons and prop affected by const operationsat time of inspection, at time of inspection observed no overhead protection provided @ terrace level 12th fl east & north elev, while alt w
Mar 10, 2010 · Penalty $2,400
Resolve - Class - 1
Failure to maintain bldg in code compliant manner use of prohibited door and or hardware per bc 1008.1.8 defect noted:at cellar commerical parking garage one emergency exit door is locked w/keyed mortise dead
Nov 7, 2009 · Penalty $1,000
Resolve - Class - 1
Sec. 3310.3. failure to file and obtain site safety plan - upon inspection noted alteration work under the permit has commenced, roofing tiles and roofing materials on 18th flr setback has been partially
Nov 4, 2009 · Penalty $1,600
Resolve - Non-hazardous
Sec. 27-777. failure to comply w/exhaust location reference standard #13-2-3-4-3. defect noted: laundry exhaust discharge is terminated w/i 10' of dental office windows. noted location: exposure #4
Feb 13, 2008 · Penalty $200
Resolve - Non-hazardous
Sec. 27-1055. cd-5 "notification of use" & approved plans not on site.approved plans not available for inspection. no protection of ropes around sharp bends. (around bulkhead brickwork). ropes or cables shall
Oct 18, 2007
Resolve - Hazardous
Wire rope to make an eye is required to have a thimble & 3 cable clamps missing thimble & 3 clamp
Oct 17, 2007 · Penalty $750
Resolve - Non-hazardous
Failure to maintain bldg.defects noted:sub-cellar garage has 2 illuminated exit signs out to west 73 street & 1 exit illuminate sign fixturemissing on outside door to west 74 street exit.remedy:repair/replace/
Oct 2, 2007 · Penalty $180
Resolve - Non-hazardous
Sec.27-1042. failed to notify the dept of bldg prior to use or installation of "c"hooks.in connection w/suspended scaffolds.all scaffolds are to be erected & maintained so that the safety of the public & proper
Aug 29, 2007 · Penalty $1,000
Resolve - Non-hazardous
Violation: failure to provide a system of automatic sprinkler where required. remedy: provide automatic sprinkler. automatic sprinkler to be installed as fire protection where two or more gas dryers located.
Mar 30, 1999 · Penalty $400
Resolve - Non-hazardous
02l 22d 31g 40u 73o 02 defective 22 secure 37 remove jumper 40 perform 5yr test 73 clean installation
Mar 2, 1999
Resolve - Non-hazardous
73x 73 restore to sevice
Mar 2, 1999
Resolve - Non-hazardous
07l 31r 40u 73o 07 repair 37 properly wire controller 40 perform 5yr test 73 clean installation
Mar 2, 1999
Resolve - Non-hazardous
37r 40u 73o 37 properly wire controller 40 perform 5yr test 73 clean installation
Mar 2, 1999
Resolve - Non-hazardous
37r 40u 75o 37 properly wire contoller 40 perform 5yr test 73 clean installation
Mar 2, 1999 · Penalty $2,500
Resolve - Non-hazardous
02l 37r 40u 46h 73o 02 repair 37 properly wire controller 40 perform 5yr test 46 excessive crown wear on hoist cables replace 73 clean installation
Mar 2, 1999
Resolve - Non-hazardous
22d6,57o2. 22-secure emergency exit hatch. 57-clean pit.
Jan 23, 1998
Resolve - Non-hazardous
57o2,xq6,37d6. 57-clean pit. x-fan wiring no in pipe (emt). 37- rectifer back of controller not secure.
Jan 23, 1998
Resolve - Non-hazardous
46h12,57o2. 46-hoist cables worn. 57-clean pit.
Jan 23, 1998
Resolve - Non-hazardous
22c6,41m7. 22-secure emergency exit hatch. 41-governor sw cover missing.
Jan 23, 1998
Resolve - Hazardous
Violation of parking regulations in a residential district. renting garage space to outside people before renting space to tenants. remedy-discontinue illegal parking.
May 29, 1992
Resolve - Non-hazardous
(74) file and obtain permit for illegaly installed required sheave andpave tested by a member or this dept
May 22, 1992
Resolve - Non-hazardous
Violation of parking regulations in a residential district renting garage space to outside people before renting space to tenant. remedy-discontinue illegal parking.
Mar 4, 1992
Resolve
Complaints
- Heat/hot water
Entire building
Dec 2, 2025 · Apt 10ME
Close - Heat/hot water
Entire building
Mar 17, 2022 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 26, 2022 · Apt BLDG
Close - Unsanitary condition
Pests
Nov 18, 2021 · Apt 2PE
Close - Unsanitary condition
Pests
Nov 8, 2021 · Apt 2PE
Close - Unsanitary condition
Pests
Dec 24, 2018 · Apt GEW
Close - Safety
Window guard broken/missing
Dec 5, 2016 · Apt 11SW
Close - Heat/hot water
Entire building
Jan 14, 2016 · Apt 1PW
Close - Heat/hot water
Entire building
Mar 17, 2015 · Apt BLDG
Close - Heat/hot water
Entire building
Oct 20, 2014 · Apt 2PE
Close
Show 8 more ↓
- Heating
Heat related
Jan 2, 2014 · Apt 616
Close - Heating
Heat related
Dec 9, 2013 · Apt 1FW
Close - Heating
Heat related
Feb 22, 2013 · Apt 1FW
Close - Nonconst
Vermin
Jul 21, 2010 · Apt 5VE
Close - Heating
Heat related
Jan 25, 2008 · Apt BLDG
Close - Heating
Heat related
Feb 5, 2007 · Apt 2P
Close - Heating
Heat related
Dec 8, 2003 · Apt 5K
Close - Heating
Heat related
Oct 5, 2003 · Apt BLDG
Close
Sales history
| Date | Price | Type | Units |
|---|---|---|---|
| Sep 15, 2026 | $800,000 | Coops - elevator apartments | — |
| Aug 27, 2026 | $570,000 | Coops - elevator apartments | — |
| Jul 22, 2026 | Non-market transfer | Coops - elevator apartments | — |
| Jul 6, 2026 | Non-market transfer | Coops - elevator apartments | — |
| Jun 4, 2026 | $600,000 | Coops - elevator apartments | — |
| Jun 2, 2026 | Non-market transfer | Coops - elevator apartments | — |
| May 28, 2026 | $1,056,250 | Coops - elevator apartments | — |
| May 22, 2026 | $575,000 | Coops - elevator apartments | — |
| May 21, 2026 | $760,000 | Coops - elevator apartments | — |
| May 6, 2026 | $1,395,000 | Coops - elevator apartments | — |
| Apr 30, 2026 | $608,000 | Coops - elevator apartments | — |
| Mar 20, 2026 | $665,000 | Coops - elevator apartments | — |
| Mar 3, 2026 | $2,310,000 | Coops - elevator apartments | — |
| Feb 25, 2026 | $3,330,000 | Coops - elevator apartments | — |
| Feb 20, 2026 | Non-market transfer | Coops - elevator apartments | — |
| Feb 20, 2026 | $1,342,500 | Coops - elevator apartments | — |
| Feb 19, 2026 | $1,050,000 | Coops - elevator apartments | — |
| Feb 5, 2026 | $1,200,000 | Coops - elevator apartments | — |
| Feb 3, 2026 | $1,650,000 | Coops - elevator apartments | — |
| Jan 30, 2026 | $685,000 | Coops - elevator apartments | — |
Building details
- Building type
- Elevator apartment building (D4)
- Year built
- 1950
- Floors
- 19
- Residential units
- 636
- Building area
- 689,522 ft²
- Lot area
- 76,300 ft²
- Zoning
- R10A
- Community board
- 107
- Council district
- 6
- Block / lot
- 1184 / 31
- Assessed value
- $82,561,050
- Landmark / historic district
- West End-Collegiate Historic District Extension
HPD registration #103664, last renewed Sep 4, 2025.
Questions about 11 Riverside Drive
Who owns 11 Riverside Drive?
The owner of record in NYC Department of City Planning PLUTO data is Eleven Riverside Drive Corp.
Does 11 Riverside Drive have violations?
Yes. NYC HPD has recorded 5 housing violations at this property.
Is 11 Riverside Drive rent stabilized?
NYC Department of Finance tax bills listed 11 rent-stabilized units here in 2024 (about 2% of its 636 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 11 Riverside Drive built?
City records list 1950 as the year it was built.
How many apartments are in 11 Riverside Drive?
It has 636 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.