42-11 College Point Blvd
Queens, NY 11355BBL 4-05101-0007Map
Owner of record: Hu Hua Realty LLC
42-11 College Point Blvd is a mixed residential and retail building built in 2010 in Queens, 11355. It has 6 residential units across 5 floors. The owner of record is Hu Hua Realty LLC. HPD has recorded 5 housing violations here, most recently on April 20, 2021. City tax records listed 6 rent-stabilized apartments here in 2024.
- HPD violations
- 5
- DOB violations
- 3
- ECB violations
- 31
- HPD complaints
- 3
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 5
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 20, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 26, 2018
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 29, 2016
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 20, 2015
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Mar 4, 2015
Closed — Violation dismissed
DOB building violations · 3
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 24, 2016
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 24, 2016
Dob violation - active - Construction other optional
C-construction other optional
Sep 7, 2007
Vw*-violation - work w/o permit dismissed
ECB violations · 31
- Class - 2
Permanent dwelling used/converted for other than permanent residentialpurposes. certificate of occupancy #416166369 indicates 5story bldg tobe legally approved as multipled dwelling class "a"apt building on 2nd
May 25, 2016 · Penalty $800
Resolve - Class - 1
Occupancy contrary to that allowed by the certificate of occupancy, illegal occupancy noted: cellar occupied as dwelling/sleeping/class"a"atp as one bedroom; room #2 kitchen, 3pc bth.contrary to co$416166.369
May 25, 2016 · Penalty $2,400
Active - Class - 2
Bc1205.2 failure to provide referral lightr for 2 bedroom on 2nd floorrear apt and bedroom/room#2 in cellar. part of class"a"apt. rmdy:discontinue illegal occupancy/comply w/code.
May 25, 2016
Resolve - Class - 1
Bc907.7.8. failure to provide fire alarm system in transiently occup ied bldg. rmdy:discontinue illegal occupancy.
May 25, 2016 · Penalty $1,600
Resolve - Class - 1
Work w/o a permit. illegal work noted: on 2nd floor rear apt having erected full height partitions to create 3 additional rooms/bedrooms. with electric lines. in cellar standup shaver with waste, water lines.
May 25, 2016 · Penalty $1,600
Active - Class - 1
Failure to maintain bldg in code-compliant manner:failure to provide number of required means of egress for every floor per bc 1018.1 (2008code) 27-366; bc 1021.1 (2014 code) for transiently occupied building
May 25, 2016 · Penalty $1,200
Resolve - Class - 2
Bc715 failure to provide opening protectives per bc 715.3.7 noted:at 2nd floor level of residential floor fire exit door leading into public staircase.wide open and secured in open position.rmdy:keep fire exit
May 25, 2016 · Penalty $400
Resolve - Class - 2
Failure to post signs at job site pursuant to subsection.note:signs posted do not comply & do not contain addresses for owner & contractor. at site of nb.remedy:provide job signs that comply.
Nov 10, 2009
Resolve - Class - 2
Failure to file certificates of correction for vio #34770027m, 34770026k. remedy:file certificate of correcttion.
Nov 10, 2009 · Penalty $400
Resolve - Class - 2
Failure to provide approved plans at job site at time of inspection. remedy: stop all work provide approved plans.
Sep 28, 2009 · Penalty $250
Resolve
Show 21 more ↓
- Class - 2
Work does not conform to approved plans. noted: "c" joist on 2nd fl,3 rd fl, 4th fl do not conform. no blocking between "c"joist. plans not complete. remedy: stop all work. provide full set of plans, conform to
Aug 25, 2009
Resolve - Class - 2
Work does not conform to approved plans. noted: "c" joist at balcony 2nd,3rd, & 4th fl do not conform. no blocking between "c"joist. plans incomplete. remedy: stop all work, provide full set of plans, conform
Aug 25, 2009
Resolve - Class - 1
Failure to provide sidewalk shed where required. noted: at time of inspection on an active construction site bldg up to 4 flrs forming 5th flr deck, approx height 48' no sidewalk shed erected to protect public
Jul 29, 2009 · Penalty $4,800
Resolve - Class - 2
Required signs. noted: at time of inspection bldg up to 4 stories no 311 sign or correct type of contractors signs installed. remedy: provide all required signs on all street fronts.
Jul 29, 2009 · Penalty $800
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperations: noted: at time of inspection on an actvie construction site, bldg up to 4th flr forming 5th flr deck. no temp lights, no guard
Jul 29, 2009 · Penalty $2,400
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. concrete foundation walls in place thru-out with wall thickness 12 inches at front/rear/exposure 2 north side & 24 inches at
Apr 9, 2009
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. concrete foundation walls in place thru-out with wall thickness 12 inches at front/rear/exposure 2 northside & 24 inches at
Apr 9, 2009
Resolve - Class - 2
Work does not conform to approved construction plan documents and/or approved amendments. concrete foundation walls in place thru-out with wall thickness 12 inches at front/exposure 2 eastside/exposure 4 westsi
Apr 9, 2009
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. concrete foundation walls in place thru-out with wall thickness 12 inches at front/exposure 2 - eastside/exposure 4 westside
Apr 9, 2009
Resolve - Class - 2
Misc violations. failure to comply with safety requirement during construction operation pursuant to 27-203. noted: at front & exposure 2 no guardrail provide for fall protection. exposed rebars uncapped. no te
Apr 9, 2009
Resolve - Class - 2
Misc violations. failure to comply with safety requirement during construction operation pursuant to 27-203. noted: at front & exposure 2 no guardrail provided for fall protection. exposed rebars uncapped. no
Apr 9, 2009
Resolve - Class - 2
Misc violations. failure to comply with safety requirement during construction operation pursuant to 27-203. noted: at front & exposure rebars uncapped. no temporary access to go to cellar level. water proofing
Apr 9, 2009
Resolve - Class - 2
Misc. violations. failure to comply with safety requirement during construction operation pursuant to 27-203. noted: at front & exposure 2 no guardrail provided for fall protection. exposed rebars uncapped. no
Apr 9, 2009
Resolve - Class - 2
Provision of law 27-195 miscellaneous violations. failure to notify dib within 24-48 hours of the start of excavation * noted: excavation started and partial foundation in place at exp.1 rem: comply with notice
Mar 3, 2009
Resolve - Class - 2
Failure to safeguard all persons and property affected by constructionoperations no smoking signs within construction site not observed in violation of nyc fire code 1404.1 and fc310 location: frontage of fence
Feb 25, 2009 · Penalty $1,200
Resolve - Class - 2
Sec bc3303.2.4 misc violations failure to provide temporary or permanent sanitary facilities during construction operations currently: operations of soil grading for concrete form work to accommodate bldg footi
Feb 25, 2009
Resolve - Class - 2
Failure to post signs at jobsite pursuant to subsection currently signage posted is inaccurate and not current w/ dob record location: public street known as sanford ave rem: post signage
Feb 25, 2009
Resolve - Non-hazardous
Work w/o a permit.work noted:found at premises 2-hydraulic & 1 electric lifter.remedy:obtain a permit.
Feb 27, 2007 · Penalty $250
Resolve - Non-hazardous
Altered bldg occupied w/o a valid cetificate of occupancy.entire bldg occupied.alt#402002079 disapproved 9/21/04.bsa variance#74-56bz expired 2/5/92.remedy:discontinue illegal occupancy or obtain valid c of o
Feb 27, 2007 · Penalty $180
Resolve - Non-hazardous
Occupancy contrary to that allowed by certificate of occuapncy. c of oexpired at 02/05/92 #197947 new was filed #402002079 at 09/10/04 and was disapproved. remedy: amend c of o or restore premises to prior
Dec 28, 2005
Resolve - Non-hazardous
Altered building occupied without a valid certificate of occupancy co 197947 has expires as per bsa #74-56bz alt 1 402002079 has been files & disapproved as of 9/21/04 providing pending bsa hearing remedy:obtai
Jan 14, 2005 · Penalty $350
Resolve
Complaints
- Door/window
Door frame
Dec 12, 2023 · Apt PVT
Close - Unsanitary condition
Pests
Dec 12, 2023 · Apt PVT
Close - Plumbing
Basin/sink
Dec 12, 2023 · Apt PVT
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Mixed residential and retail building (S9)
- Year built
- 2010
- Floors
- 5
- Residential units
- 6
- Building area
- 8,976 ft²
- Lot area
- 2,074 ft²
- Zoning
- R6
- Community board
- 407
- Council district
- 20
- Block / lot
- 5101 / 7
- Assessed value
- $929,700
- Landmark / historic district
- No
HPD registration #429612, last renewed Aug 26, 2025.
Questions about 42-11 College Point Blvd
Who owns 42-11 College Point Blvd?
The owner of record in NYC Department of City Planning PLUTO data is Hu Hua Realty LLC.
Does 42-11 College Point Blvd have violations?
Yes. NYC HPD has recorded 5 housing violations at this property.
Is 42-11 College Point Blvd rent stabilized?
NYC Department of Finance tax bills listed 6 rent-stabilized units here in 2024 (about 100% of its 6 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 42-11 College Point Blvd built?
City records list 2010 as the year it was built.
How many apartments are in 42-11 College Point Blvd?
It has 6 residential units and 8 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.