roofy

296 Wythe

Brooklyn, NY 11249BBL 3-02378-0021Map

Owner of record: Wythe Owner LLC

296 Wythe is an elevator apartment building built in 2021 in Brooklyn, 11249. It has 55 residential units across 6 floors. The owner of record is Wythe Owner LLC. HPD has no housing violations on record for this property. City tax records listed 17 rent-stabilized apartments here in 2024.

HPD violations
0
DOB violations
4
ECB violations
35
HPD complaints
5

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
17
About 31% of the building's 55 apartments
Down from 42 in 2023

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 4

  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2023

    Dob violation - dismissed
  • Construction other optional

    Special inspector, alberto roman, pe#95364 surrendered all filing privileges, therefore pursuant to ac 28-105.10.2. borough commissioner has ordered swo under application #b00649524.

    Aug 27, 2022

    Dob violation - dismissed
  • Construction other optional

    Special inspector, alberto roman, pe#95364 surrendered all filing privileges, therefore pursuant to ac 28-105.10.2. borough commissioner has ordered swo under application #b00649524.

    Aug 27, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 27, 2018

    Dob violation - dismissed

ECB violations · 35

  • Class - 1

    Failure to submit the required parking structure initial observation report for an existing parking structure or a periodic inspection of a parking structure(pips) report documenting the conditions of psid#b000

    Oct 1, 2024

    Resolve
  • Class - 1

    Failure to submit the required parking structure initial observation report for an existing parking structure or a periodic inspection of a parking structure(pips) report documenting the conditions of psid#b000

    Oct 1, 2024

    Resolve
  • Class - 2

    Bc3307.2.6 observed sws erected@exp1,2,4 (corner b/w grandst&wytheave,corner b/w wytheave&n1st) w/o mirrors@all blind corners as required.this poses threats to public&pedestrians as pedestrians unable to avoid

    Apr 22, 2022 · Penalty $625

    Resolve
  • Class - 1

    Failure to comply w/manufacturers specs stop all use of barricaded zone along w curbline on wytheave b/w grand&n1sts,not following manufacturers specs to add weight to plastic barricades to protect from vehicul

    Mar 1, 2022

    Resolve
  • Class - 1

    Bc3307.2.1 requirements of dot shall apply w/regard to obstruction of sts of any part of.stop all occupancy of roadway/street along east curb line on wytheave.only allowed to fix violating conditions-call cse f

    Mar 1, 2022

    Resolve
  • Class - 1

    Failure to comply w/manufacturer specs stop all use of concrete embedded safety straps&all perimeter work provide insp safety log of daily insps of embedded safety straps.call cse for reinsp.note:ato my insp of

    Mar 1, 2022

    Resolve
  • Class - 1

    Work w/o a permit. at time of inspection of 6 sty nb active job site,observed that all concrete operation completed & bldg is topped off observed workers performing materials delivery & interior framing & other

    Jan 27, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    Sec. 3314.1 unsafe supported scaffold. note: at the time of my inspection i observed a supported in place. 1)damaged & loose debris,netting 2)bracing members not connected 3)no guardrails in place 4)not fully

    Aug 20, 2020

    Resolve
  • Class - 1

    Failed to notify the dept of buildings.note:at the time of my inspection and review of the superintendent logbook for site,296 wythe ave,bk notes signed by daniel matovinovic(superintendent)reported that worker

    Jul 2, 2020

    Resolve
  • Class - 1

    Superintendent failed to perform duties.note:at the time of my inspection and review of the superintendent logbook for site 296 wyth ave,bk notes signed by daniel matovinovic indicated that a worker was injured

    Jul 2, 2020 · Penalty $10,000

    Resolve
Show 25 more ↓
  • Class - 1

    Working contrary to swo.note:at the time of my inspection of a demo site under a swo(stop work order)for the damage of the adjacent propertyi observed that the sidewalk shed was partially removed new holes were

    Jul 2, 2020

    Resolve
  • Class - 1

    Working contrary to swo.note:at the time of my inspection of a jobsiteon a stop work order given 06/17/20 by j.katakatsan is #2980 superintendent logbooks shows a fence that was moved a scaffold that was erecte

    Jul 2, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Work does not conform to approved construction docs.at time of inspection and 1 stry demo site obsered at expo#3 broong in place for adjacent property wall.upon review of bracing detail on soe plans provided fo

    Jun 17, 2020

    Resolve
  • Class - 1

    Sec. 3301.13.5 alternate construction superintendent at time of inspection of a 1 sty full demolition on an active job site designated construction superintendent chaim reisman#0027021 not on site upon review

    Apr 28, 2020

    Resolve
  • Class - 1

    Failure to safeguard public & property affected by construction operations. at time of inspection of a 1 sty full demo in response to complaint where it was reported adjacent property has been damaged during

    Apr 28, 2020

    Resolve
  • Class - 1

    Alternate construction superintendent. at time of inspection of a 1 sty full demolition on an active job site designated construction superintendent chaim reisman #0027021 not on site upon review of daily log

    Apr 28, 2020

    Resolve
  • Class - 1

    Failure to immediately notify the dept of damage to adjoining property. at time of inspection of a 1 sty full demolition on an active jobsite in response to compliaint#3751024 where it was reported adjacent pro

    Apr 28, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Construction superintendent failed to perform duties as per code. at time of inspection of a 1 sty full demolition on an active jobsite construction superintendent not on site in response to complaint#3751024

    Apr 28, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Construction superintendent failed to perform duties as per code. at time of inspection of a 1 sty full demolition on an active job site construction superintendent not on site upon request for daily log to ver

    Apr 28, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Permit holder failed to ensure workers attend pre-shift meeting prior to commencement of work.at time of inspection of a 1 story full demo on an active job approx 5 workers on site construction superintendnet a

    Apr 20, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Construction superintendnet failed to perform duties as per code.at time of inspection of a 1 story full demo on an actiev job approx 5 workers on site upon review of superintendnet log provided on site i obser

    Apr 20, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Permit holder failed to ensure workers attend pre-shift safety meeting prior to commencement of work.at time of inspection of a 1 stoy full demo on an active job approx 5 workers on siteconstruction superintend

    Apr 20, 2020

    Resolve
  • Class - 2

    Construction superintendent failed to perform duties as per code.at time of inspection of a 1 story full demo on an active job approx 5 workers on site superintendent not on site no competent person on site no

    Apr 20, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply w/ dot regulations as per rcny 2-05 and admin code provision 19-107 19-108 or 19-121 and nyc bc 3307.4.7. at the time of my inspection,i observed boom lifts being stored at exposure#1. the boo

    Jan 4, 2020 · Penalty $625

    Resolve
  • Class - 2

    Sec. 3309.9 weatherproof integrity of adjoining bldg. at time of inspection of proposed new 6 sty bldg,i observed at exp#3 approx 40 feet inlength & 20 feet in height,party wall not weatherproofed as required

    Sep 10, 2019

    Resolve
  • Class - 2

    Sec. 3303.13.3 filling & grading. at time of inspection of proposed new 6 sty bldg. i observed vacant bldg installed phase of construction where interior grading was compromised dirt fill was washed away in som

    Sep 10, 2019

    Resolve
  • Class - 2

    Sec. 28-301.1 fail to maintain bldg in code complaint manner. at time of inspection of proposed new 6 sty bldg i observed bldg in a stalled phase of construction/demo w/no work going on. i observed bldg structu

    Sep 10, 2019

    Resolve
  • Class - 2

    Housekeeping. at time of inspection of proposed 6 sty new bldg,i observed at roof level large amount of loose plywood & pieces of ventalation system hanging in danger of falling to vacant & stalled construction

    Sep 10, 2019

    Resolve
  • Class - 2

    Sec. 3301.2 fail to maintain safety. at time of inspection of proposednew 6 sty bldg i observed inadequately maintained & missing terra-cotta at exp#3 parapet wall. this condition created a hazard of falling

    Sep 10, 2019

    Resolve
  • Class - 2

    Sec. 3303.13.2 safety monitoring plan. at time of inspection of proposed new 6 sty bldg,i observed jobsite installed phase of construction/demo that has been open longer than 3 months w/o any work being perform

    Sep 10, 2019

    Resolve
  • Class - 2

    Sec. 3307.3.1 failure to provide sidewalk where required. at time of inspection of proposed new 6 sty bldg,i observed there was no sidewalk shed provided throughout jobsite at exp#1,2,4. failure to provide side

    Sep 10, 2019

    Resolve
  • Class - 1

    Reissue violation #35303763y. failure to maintain building wall(s) or appurtenances. note: at exp #3 bricks and coping stones at top area of wall on poor and unstable conditions. rem: maintain exterior building

    Aug 5, 2018

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35303763y issued on 04-05-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. failure to maintain bldg walls or appurtenances. remedy: comply

    Jun 23, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to comply with the commissioners order contained in summons/violation#35303763y issued on 04/05/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.failure to maintain build

    May 18, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain bldg walls or appurtenances. observed exp#3 of brick masonry wall w/loose & missing bricks & coping stones at upper section of wall in poor & unstable condition presenting hazard to rear yar

    Apr 5, 2018 · Penalty $2,500

    Resolve

Complaints

  • Heat/hot water

    Apartment only

    Jan 10, 2025 · Apt 2D

    Close
  • Heat/hot water

    Apartment only

    Jan 10, 2025 · Apt 2D

    Close
  • Heat/hot water

    Entire building

    Jan 10, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Dec 6, 2024 · Apt 2E

    Close
  • Heat/hot water

    Entire building

    Jan 4, 2021 · Apt 4R

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D6)
Year built
2021
Floors
6
Residential units
55
Building area
84,145 ft²
Lot area
15,985 ft²
Zoning
M1-2/R6A
Community board
301
Council district
33
Block / lot
2378 / 21
Assessed value
$9,600,300
Landmark / historic district
No

HPD registration #390686, last renewed Jul 10, 2025.

Questions about 296 Wythe

Who owns 296 Wythe?

The owner of record in NYC Department of City Planning PLUTO data is Wythe Owner LLC.

Does 296 Wythe have violations?

NYC HPD has no housing violations on record for this property.

Is 296 Wythe rent stabilized?

NYC Department of Finance tax bills listed 17 rent-stabilized units here in 2024 (about 31% of its 55 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 296 Wythe built?

City records list 2021 as the year it was built.

How many apartments are in 296 Wythe?

It has 55 residential units and 57 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.