243 4th Avenue
Brooklyn, NY 11215BBL 3-00958-7504Map
Owner of record: 243 Development LLC
243 4th Avenue is a condominium built in 2018 in Brooklyn, 11215. It has 19 residential units across 12 floors. The owner of record is 243 Development LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 2
- ECB violations
- 30
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 2
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2021
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2021
Dob violation - dismissed
ECB violations · 30
- Class - 1
Elevator not in readiness. at time of inspection of a 12 story nb cur-rently at roof level in response to complaint i observed elevators not working for fire department use as per code. stop all work above 75 f
Nov 14, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/violation#35432741y issued on 6/30/19 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.for: bc 3301.12. no eleva
Aug 29, 2019
Resolve - Class - 1
Failure to comply w/an order of the commissioner. as documented in thedob control#279941,vio#070919 ce30601ge,the respondent was required tosubmit all installation,adjustment,repair,maintenance,pre-shift & remo
Aug 12, 2019 · Penalty $2,500
Resolve - Class - 1
Work does not conform to approved construction documents & approved amendments. note: at the time of my inspection of a 12 sty bldg at roof level construction work in progress. i observed supported pipe erected
Aug 12, 2019 · Penalty $2,500
Resolve - Class - 1
Bc 3303.3 watchperson. note-at the time of my inspection of 12 story new building,upon my inspection i observed there was no watchperson on site. the building's footprint is(5432 sq ft) where a watchperson is r
Aug 8, 2019
Resolve - Class - 1
Bc3314.5.5/platform tiedown;note:at the time of my inspection of a 12 story building scaffolding loose and unsecure platfors on supported scaffolding erected approximately 30 feet in height on 10 floor setback
Jul 1, 2019 · Penalty $2,500
Resolve - Class - 1
Bc3307.4/warning signs,personnel and barriers.note:at the time of my inspection i observed barriers provided for temporary walkway in roadway was inadequate as barriers were not full as per manufacturer specifi
Jul 1, 2019
Resolve - Class - 1
Bc3307.4.6/prohibited outdoor company sign on sidewalk shed or construction fence.note:at the time of my inspection of a 12 story building roof level construction work in progress.i observed approximately 170ft
Jul 1, 2019 · Penalty $625
Resolve - Class - 1
Failure to safeguard all public and property affected by construction operations.note:at the time of my inspection of a 12 story building atroof level approximately 125ft above adjacent property driveway at exp
Jul 1, 2019
Resolve - Class - 1
Bc3303.4.2/containers.note:at the time of inspection of a 12 story building at roof level construction work in progress.i observed a 30 yarddumpster on roadway at exposure one being use for debris i also observ
Jul 1, 2019 · Penalty $625
Resolve
Show 20 more ↓
- Class - 1
Bc3310.10/site specific safety oreintation program for all workers.note:at the time of my inspection of a 12 story building at roof level construction work in progress.upon request and review of site specific o
Jul 1, 2019
Resolve - Class - 1
Site safety coordinator failed to immediately notify the department ofconditions as required sidewalk shed as per ssp.note:at time of my i nspection of a 12 story building at roof level.i observed approximatel
Jul 1, 2019
Resolve - Class - 1
Bc3314.4.3.3/installation inspection for supported scaffold.note:at the time of my inspction of a 12 story building at roof level construction work in progress.i observed supported scaffold erected at exposure
Jul 1, 2019 · Penalty $2,500
Resolve - Class - 1
Filed a certificate of correction or other related materials containing material false statements.note:at time of my inspection i observed outdoor advertising sign on sidewalk shed at exposure outdoor advertisi
Jul 1, 2019 · Penalty $5,030
Resolve - Class - 1
Sidewalk shed where required.note:at the time of my inspection of a 12story building at roof level construction work in progress i observed that there was approximately 30ft of sidewalk shed missing at exposure
Jul 1, 2019 · Penalty $10,000
Resolve - Class - 1
Bc3314.4.3.6/inspection following site repair or adjustment.note:responding to follow up inspection where partial scaffolding collapse unto adjacent property roof and walkway at exposure 4 injuring one inspecti
Jul 1, 2019 · Penalty $12,500
Resolve - Class - 1
Site safety coordinator failed to immediately notify the department ofconditions as required-elevator in readiness note:at the time of my inspection of a 12 story building at roof level review of site safety lo
Jul 1, 2019 · Penalty $2,500
Resolve - Class - 1
Site safety cooridnator failed to immediately notify department of conditions as required-elevator in readiness.note:at the time of my inspection of a 12 story building at roof level approximately 125ft in heig
Jul 1, 2019
Resolve - Class - 1
Failure to safeguard public+property affected by construction operations. at roof level 12'high pipe scaffolding surrounding bulkhead+mechanical room collapsed due to no tie backs in place onto property located
Jun 30, 2019 · Penalty $25,000
Resolve - Class - 1
Failure to notify the dept of an incident that resulkted in a injury or fatality.(three)pedestrians were injuried & taken to hospital by ambulance. when pipe scaffolding from the roof fell into the court yard
Jun 30, 2019
Resolve - Class - 1
Bc 3301.12 no elevator in readiness available for use at time of inspection as per chapter 30 bc 3318. elevator out of service at time of inspection. remedy: provide elevator in readiness
Jun 30, 2019
Resolve - Class - 1
Failure to provide sidewalk shed where required. at time of inspectionit was observed that a fully erectd 12story building was at location, and at the roof level and at front exp1, work was still in progress.
Jun 10, 2019 · Penalty $12,500
Resolve - Class - 2
Pedestrian note:at the time of my inspection of a 12 story building at roof level site closed i observed approximatey 50 feet of sidewalk shed at exposure one was not provided with any illuminated electrica lig
Jun 8, 2019 · Penalty $2,400
Resolve - Class - 1
Bc3314.8.1/guardrail system.note:at the time of my inspection of a 12 story building at roof level construction work in progress.i observed open sides and ends of supported pipe scaffold interior was not provid
Apr 2, 2019 · Penalty $2,500
Resolve - Class - 1
Prohibited outdoor advertising company sign on sidewalk shed or construction fence.note;at the time of my inspection of a 12 story building at roof level construction work in progress.i observed approximately 2
Apr 2, 2019
Resolve - Class - 1
Failure to protect sides of excavation.(sheer cut)at time of inspection,i observed at exp#3 missing timber lagging where there is a sheer cut opening w/no protection. bottom of footing was excavated approx 24"
Apr 18, 2018 · Penalty $5,000
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction.(guardrails)at time of inspection,i observed at openings where workers were doing rebards,there were no guardrails it create a
Apr 18, 2018 · Penalty $2,500
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction(no toeboards). at time of inspection,i observed guardrailsw/missing toeboards. contractor failed to provide toe boards for safet
Apr 18, 2018 · Penalty $2,500
Resolve - Class - 1
Failure to notify dob w/in 24-48 hrs of the start of excavation.at time of excavtion it was noted that the contractor failed to notify the dob prior to the start of earthwork as reqd by code.our records indicat
Feb 13, 2018 · Penalty $3,000
Resolve - Class - 1
Work does not conform to approved docs nd/or approved amendments.at time of inspection,the contractor installed walers and rakers at exp#2and #4.the rakers were attached to the piles,but the rakers had to be cu
Feb 13, 2018 · Penalty $2,500
Resolve
Complaints
- Heat/hot water
Entire building
Dec 30, 2025 · Apt BLDG
Close - Plumbing
Water supply
Dec 30, 2025 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RM)
- Year built
- 2018
- Floors
- 12
- Residential units
- 19
- Building area
- 41,098 ft²
- Lot area
- 5,459 ft²
- Zoning
- C4-4D
- Community board
- 306
- Council district
- 39
- Block / lot
- 958 / 7504
- Assessed value
- $6,176,879
- Landmark / historic district
- No
Questions about 243 4th Avenue
Who owns 243 4th Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 243 Development LLC.
Does 243 4th Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 243 4th Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 243 4th Avenue built?
City records list 2018 as the year it was built.
How many apartments are in 243 4th Avenue?
It has 19 residential units and 21 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.