112 Schermerhorn Street
Brooklyn, NY 11201BBL 3-00169-0009Map
Owner of record: New York Quarterly M
112 Schermerhorn Street is a school building built in 1857 in Brooklyn, 11201. The owner of record is New York Quarterly M. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 19
- ECB violations
- 64
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 19
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed
Show 9 more ↓
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed - Construction other optional
C-construction other optional
Jun 12, 1990
Dob violation - active
ECB violations · 64
- Class - 2
Reissue: 35691811r-failure to maintain building in code-compliant manner: custodian office is in the electrical/gas meter rm. also noted: buckets, cleaning materials, boxes ofc. remedy: comply with code.
Feb 3, 2026 · Penalty $3,125
Active - Class - 2
Reissue: 35678628m-failure to maintain building in code-compliant manner: cellar level electrical rm and gas meter rms are being used as custodian office. remedy: comoly with code.
Feb 25, 2025 · Penalty $3,125
Active - Class - 2
Reissue: 35671600z-failure to maintain building in code-compliant manner: at cellar level electrical rm. also used for custodian office has storage. remedy: comply with code.
Jan 30, 2024 · Penalty $1,562
Active - Class - 2
Reissue: 35632049y-failure to maintain building in code-compliant manner: cellar level gas room being occupied by custodian office and storage. remedy: comply with code.
Jan 30, 2024 · Penalty $1,562
Resolve - Class - 2
Reissue#35643278l.failure to maintain building in code compliant manner.noted at cellar at electrical meter room,illegal storage of paint buckets,metal pipes plastic bins,refridgerator,etc.remedy:remove illegal
Jan 26, 2023 · Penalty $1,562
Resolve - Class - 2
Reissue#35643279n.failure to maintain building in code compliant manner.noted at cellar gas meter room is occupied as a custodian office along with other illegal storage.remedy:comply with violation.
Jan 26, 2023 · Penalty $1,562
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted on 2nd floor next to room 220,smoke door do not close properly.remedy:repair and/or replace door.
Jan 26, 2023 · Penalty $625
Resolve - Class - 2
Reissued#35553800x failure to maintain building in code-compliant manner:noted:observed at cellar's boiler room/electrical room/gas meter room a section is arranged and occupied as the custodians office with de
Mar 11, 2022 · Penalty $1,562
Resolve - Class - 2
Reissued#35553802j failure to maintain building in code-compliant manner:noted:observed fireproof self closing doors at 2nd floor stair a and 3rd floor stair a and b are missing.rem:repair and/or replace.
Mar 11, 2022 · Penalty $1,562
Resolve - Class - 2
Reissued#35553801h failure to maintain building in code-compliant manner:noted:observed at cellar's boiler rooms/electrical room and gas meter room-excessive illegal storage of combustible materials and supplie
Mar 11, 2022 · Penalty $1,562
Resolve
Show 40 more ↓
- Class - 2
Reissue35495552n failure to maintain bldg in codecompliant manner.noted:during insp observed@cellar level-boiler1 (electrical rm area) has illegal storage of paint buckets,metal pipes,plastic bins,refrigerator,
Apr 20, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue3549551l failure to maintain bldg in codecompliant manner.noted:during insp observed@3fl-staira&b door missing&@gym-exit3 has both exit doorsnot working properly due to defective hardware/door closures.c
Apr 20, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue35495553p failure to maintain bldg in codecompliant manner.noted:during insp observed@cellar level gas meter rm/boiler1 occupied as custodian office.comply w/v&maintain bldg up to code.
Apr 20, 2021 · Penalty $1,562
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: gas meter room is occupied as custodian office. remedy: comply w/violation.
May 18, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: at 3rd fl,door missing at stair'a'&stair'b'. remedy: comply w/notice of violation.
May 18, 2020 · Penalty $625
Resolve - Class - 2
Exit door not self closing. noted: at cellar gym,exit 3,one door is not self closing due to broken door closer. remedy: repair/replace door.
May 18, 2020 · Penalty $1,562
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: at electrical room,illegal storage of paint bucket,metal pipes,plastic bins,refrigerators,showing full of hardware,etc. remedy: comply w/notice of viola
May 18, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner use of prohibited door and/or hardware per bc 1008.1.8:27-37 (j) noted:at all levels throughout in various locations installed kick door stopper at exits st
May 2, 2019 · Penalty $625
Resolve - Class - 2
Exit door not self closing noted at cellar gym exit 3 doors with having no self closers nonoperational repair replace door
May 2, 2019
Resolve - Class - 2
Failure to maintain building in code compliant manner .noted:at 2nd flor stair a, 1st fl stair a&b doors are in disrepair racked repair and/or replace
May 2, 2019
Resolve - Class - 2
Operation of place of assembly w/o a current certificate of operation.@ time of insp. observed @ 2nd fl a sanctuary with capacity to sit approx. 200 people approx. 55'x47'. also observed @ 1st fl a reading faci
Apr 11, 2019 · Penalty $800
Active - Class - 2
Failure to maintain bldg in code complaint manner. lack of emergency lighting for exits,exit discharges & public corridors per bc1006.1;27-542. noted: emergency lights not working when test by the front doors &
Oct 26, 2016 · Penalty $2,500
Active - Class - 2
Failure to maintain: noted interior horizontal cracks in bulkhead walls where wall meets roof. rmdy: obtain all necessary permits - repair defects.
May 17, 2013 · Penalty $530
Active - Class - 2
Reissue: 34953707h. interior horizontal cracks in bulkhead wall where wall meets roof. remedy: repair all cracks in bulkhead wall where wallmeets roof. remedy: repair all cracks.
Apr 19, 2013
Resolve - Class - 2
Emergency lighting at cafeteria & gym areas not operating at time of inspection. rmdy: replace lighting.
Apr 19, 2013
Resolve - Class - 2
27-369 bc1017 failure to provide unobstructed exit passageway 3rd floor exterior exit stair partially obstructed by a/c cage at rm 334 rem: remove a/c cage
Apr 12, 2012
Resolve - Class - 2
Failure to maintain interior horizontal cracks in bulkhead wall where wall meet roof rem; repair all cracks
Apr 12, 2012
Resolve - Class - 2
27-766. no fresh air vent @ cellar level, the interior gas meter room has no fresh air ventilation. rem:provide fresh air vent or (obtain permit if required) remove interior gas meter if feasible.
Jun 23, 2011
Resolve - Class - 3
50a - separate control from 1/4" line
Apr 9, 2010 · Penalty $500
Resolve - Class - 3
Failure to maintain. note: gas meter room has no fresh air vent. remedy: supply fresh air vent/maintain bldg.
Mar 19, 2009
Resolve - Class - 2
Failure to provide unobstructed passageway reissue: 34692506z note: atcellar level stair landing 2 vending machines (snapple) partially blocking stairs. at main entry: large desk apprx 3'x 5w two chairs located
Mar 19, 2009
Resolve - Class - 2
Failure to provide unobstructed exit passageway noted:at basement level snapple vending machine stored right in front of stair a exit door also on 1st fl noted tables copy machine thru-out entire fl remedy:rem
Jul 3, 2008
Resolve - Hazardous
Exterior brick wall has become porous and allowing rain water to enterthe bldg located at roof bulkhead "a" on roof level. remedy:water brick wall bulkhead.
Apr 23, 2007
Resolve - Non-hazardous
Failure to provide protection at side of excavation. upon insp of above property: approx 8'-9' deep x 15' long trench has been excavated andthere is no sheeting shoring or bracing.there also is a approx 5' high
Aug 3, 2006 · Penalty $1,000
Active - Non-hazardous
Reissue 34444791y chimney has crack's in brick and also spolding and show's day light through. remedy: repair or make new chimney.
Mar 9, 2005
Resolve - Non-hazardous
Failure to maintain defects are cracke dislodged brick on chimney.chimney is also leaning chimney is tared to hold together and shows daylight thru areas which together ans shows daylight thru areas which shoul
Jul 26, 2004
Resolve - Non-hazardous
Failure to maintain defects are old swollen cracked wood glass & metaldoors doors have broken hinges panic bars & knobs doors are hand to o pen & window egress some cases defective doors are at bulkhead 2 doors
Jul 26, 2004
Resolve - Non-hazardous
Failure to maintain,defect;indirect waste at cafeteria leaking and numerous leaks thruout entire plumbing system.remedy:maintain bldg -make all necessary repair-obtain permits.
Dec 1, 2003
Resolve - Non-hazardous
Failure to maintain. defect is: throughout interior flaking, peeling ceiling, damage v.c.t floors. remedy: maintain building, make all necessary forthwith.
Nov 18, 2003
Resolve - Non-hazardous
Failure to maintain, defect is: crack at gym, wall, flaking, peeling ceiling. remedy: maintain building, make all necessary forthwith.
Nov 18, 2003
Resolve - Non-hazardous
Failure to maintain, defect is broken, defective front & vestibule doors. remedy: maintain building, make all necessary forthwith.
Nov 18, 2003
Resolve - Non-hazardous
Failure to maintain, defect is: facade not being maintained, chip stones and open joints at brickwork throughout. remedy: maintain building , make all necessary forthwith.
Nov 18, 2003
Resolve - Non-hazardous
Failure to maintain buildings. defects are: second floor south side walls around door are crack approx 1" wide from floor to approx 20' high. remedy: maintain building forthwith.
Oct 31, 2003 · Penalty $350
Active - Non-hazardous
Re-issue. failure to maintain - noted. interior doors, brooken, warped, missing varioius locations throughout school remedy : repair / replace doors
Apr 9, 2003
Resolve - Non-hazardous
Failure to maintain - noted eixt doors throughout schoo, warped, broken, sticking rusted rotten frames all exit doors throughout remedy : repair / replace doors
Apr 9, 2003
Resolve - Non-hazardous
Failure to maintain building noted defects broken warpped rotted interior doors throughout school. remedy; repalace doors.
Jan 2, 2002
Resolve - Non-hazardous
Failure to maintain building cracted masonary facade. rear yard adjacent fire escape 3 floor verfical cracks. remedy; make repairs.
Jan 2, 2002
Resolve - Non-hazardous
Failure to maintain building (reissue) rotted exit doors (from oil tank room to street & from cateteria to street. remedy: make repairs.
Jan 2, 2002
Resolve - Hazardous
Failure to maintain exterior building wall spalling limestone window sills and keystone remedy - make safe do repair ( reissue )
Jan 2, 2002
Resolve - Non-hazardous
Failure to use panic hardware ( reissue ) where required by law. location. basemetn ( gym) remedy - provide panic hardware
Jan 2, 2002
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W2)
- Year built
- 1857
- Floors
- 3.5
- Residential units
- —
- Building area
- 28,301 ft²
- Lot area
- 16,632 ft²
- Zoning
- C6-2A
- Community board
- 302
- Council district
- 33
- Block / lot
- 169 / 9
- Assessed value
- $2,648,700
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 112 Schermerhorn Street
Who owns 112 Schermerhorn Street?
The owner of record in NYC Department of City Planning PLUTO data is New York Quarterly M.
Does 112 Schermerhorn Street have violations?
NYC HPD has no housing violations on record for this property.
Is 112 Schermerhorn Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 112 Schermerhorn Street built?
City records list 1857 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.