Owner of record: 3745 Riverdale Avenue LLC

3745 Riverdale Avenue is an elevator apartment building built in 2022 in Bronx, 10463. It has 89 residential units across 18 floors. The owner of record is 3745 Riverdale Avenue LLC. HPD has recorded 7 housing violations here, most recently on September 17, 2026. 2 of the 7 most recent violations are still open. City tax records listed 75 rent-stabilized apartments here in 2024.

HPD violations
7
DOB violations
2
ECB violations
39
HPD complaints
19

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Watch
Last violation Sep 17, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
75
About 84% of the building's 89 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 7

  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper.

    Sep 17, 2026

    Open — Nov certified on time
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building.

    Sep 17, 2026

    Open — Nov certified on time
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Jun 4, 2025

    Closed — Violation closed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system signage missing at public hall, 1st story

    Jun 4, 2025

    Closed — Violation closed
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    Jun 4, 2025

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 604, 6th story, 2nd apartment from north at east

    Apr 28, 2025 · Apt 604

    Closed — Violation dismissed

DOB building violations · 2

  • Construction other optional

    Add'l info,job#220514799=proposed 18 stry,residential concrete cast-in -place.struct.chaptr 17-bldg code req conc specimens to be collected & lab tsts perf on conc.no tr2 reslts rec'd for aug,sept,oct 2022 remedy: provide concrete enforcement unit signd/seald copies of tr2 conc testng rpts by licensd lab for referencd project and dates

    Oct 10, 2024

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2024

    Dob violation - dismissed

ECB violations · 39

  • Class - 2

    At the time of inspection, observed partially removed barricades along the temporary pedestrian walkway at the exposure 3 contrary to site safety plan. also, mirror was missing for the blind spot at exposure 2

    Jun 1, 2023 · Penalty $2,400

    Resolve
  • Class - 1

    Observed roof protection at adjacent property at exposure 4 of jobsite. there is large amounts of cement spillage and debris on the roof protection provide. *stop all exterior work exposure 4 maintain adequate

    May 11, 2023 · Penalty $6,250

    Resolve
  • Class - 2

    Observed multipoint suspended scaffold in use at exposure 2 of jobsite. the said scaffolding use an adjustable bracket system that's anchored into concrete slap. upon review on dob now for the notification it s

    May 11, 2023 · Penalty $2,530

    Resolve
  • Class - 1

    Observed multipoint suspended scaffolding system installed and in use at exposure 2 of jobsite. upon review of the provided approved drawings its shows that there are to be 9 outrigger post installed however in

    May 11, 2023 · Penalty $2,530

    Resolve
  • Class - 1

    Observed multipoint suspended scaffolding at exposure 2 and mast-climb system installation phase at exposure 1&3. upon review of the site safety plan provided onsite it was observed that none of these filed con

    May 11, 2023 · Penalty $6,250

    Resolve
  • Class - 1

    Ins.date 030923 badge 3309 ecb issued w/swo no work 14fl and above only allowed to jump hor.netting to 17fl site conditions show rebar dowls exposed exp4 near shaft at roof level,at time of inspection observed

    Mar 24, 2023 · Penalty $5,030

    Resolve
  • Class - 1

    At the time of inspection 18 stories nb i observed guard rail system on roof level are not complying as per code it was ~31" high it should be 39"+- 3" from the concrete slab as well missing toe board and need

    Mar 10, 2023 · Penalty $5,000

    Resolve
  • Class - 2

    At the time of inspection i observed stand pipe stopped at 15 fl the permanent stairs up to 17 fl which stand pipe need to be extended up the permanent stair where are 17 fl as per code and section 90 stop work

    Mar 9, 2023 · Penalty $625

    Resolve
  • Class - 2

    At the time of inspection observed striping form work on 17 floors and missing roof protection over adjacent building at exp#4 as well the horizontal safety netting wasn't install properly as per engineer desig

    Mar 9, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection nb 18 floor i observed horizontal safety netting missing net poles in each side of exp#1,3 and the spaces not as per plan on exp#2,4 max 25 feet long span required on plan at shear wal

    Mar 9, 2023 · Penalty $1,250

    Resolve
Show 29 more ↓
  • Class - 2

    At a 18 story active jobsite at roof level unenclosed. i noticed at various floor level and in staircase poor housekeeping. i noticed 2"nails and pieces of wood on unprotected balcony that could be blown off on

    Mar 2, 2023 · Penalty $1,250

    Resolve
  • Class - 1

    Note: at the time of inspection observed a 18sty building under construction at 15th floor level, active job site. observed accessible bridge bracing platform at 12th floor have missing part of guardrails. cre

    Feb 2, 2023 · Penalty $625

    Resolve
  • Class - 2

    Note: at the time of inspection observed a 18sty building under construction at 15th floor level, active job site. observed magni boom using for loading unloading construction material at 15th floor level ( ab

    Feb 2, 2023

    Resolve
  • Class - 1

    Fall protection&rebar caps 18 story nb at 11fl, i observed no rebar caps. hazard of impalement. on 8fl 1 worker tied to a reshore post, horizontal netting removed adjacent to hoist, no caz or any safety measure

    Jan 6, 2023

    Resolve
  • Class - 1

    Horizontal netting(hz) i observed 18 story nb currently on the 11fl, with workers stripping formwork on floors 8, 9 and 10. workers installing rebar on working deck on 11fl. hz on 6 floor is not fully extended

    Jan 6, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    Proposed 18 story nb currently on 11 fl, i observed temporary wooden platform in elevator shaft, with wooden ladders that serve as the only egress to floors 9, 10 and 11. upon request to view a design drawing(d

    Jan 6, 2023

    Resolve
  • Class - 2

    Reshores not secured i observed reshores at exp1 on the 3rd floor near the edge, that were not secured. only wedge in the middle, upon request to view reshore plan, none was provided. secure reshores

    Jan 6, 2023

    Resolve
  • Class - 1

    Concrete safety manager(csm) failed his duties i observed 18 st nb on the 11fl working deck. csm mr orlando silva has provided his daily log, where it shows that he checked ok on 1)horiztl netting, 2) reshore p

    Jan 6, 2023

    Resolve
  • Class - 1

    At the time of my inspection of a 18 story building at 11th floor level that include approximately 2500 cubic yard of concrete. concrete operation in progress, upon request for concrete safety manager # 2426 wa

    Dec 27, 2022 · Penalty $625

    Resolve
  • Class - 1

    At a proposed 18 story building at the 12th floor level work in progress. reviewing the department of building records revealed that no records of hydrostatic test was performed on standpipe. fail to perform h

    Dec 27, 2022 · Penalty $5,000

    Resolve
  • Class - 1

    At a proposed 18 story building at 12th floor level active site. upon requesting for site safety manager none was provided as per code and department records reveal site safety coordinator on file. building is

    Dec 27, 2022 · Penalty $10,000

    Resolve
  • Class - 1

    At a proposed 18 story building at 11th floor level closed padlocked jobsite. i went to sliding gate from both entrance of construction site and made my self known who i was,no one responded and no one was avai

    Dec 26, 2022 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain construction fence as per code. missing panels and not properly secured.maintain fence

    Oct 3, 2022 · Penalty $500

    Resolve
  • Class - 2

    Failure to protect adjoining property. undermining exiting sidewalk and it is ready to collapse.

    Oct 3, 2022 · Penalty $625

    Resolve
  • Class - 2

    At the time of inspection of a proposed 14 stories nb active jobsite under construction, i observed at exp#-2 at rear of adjoining occupied property with partially collapse concrete slab & damage cmu fence wall

    Sep 17, 2022

    Resolve
  • Class - 1

    At time of inspection of a proposed 14 stories nb active jobsite currently under const, i observed at exp#-2 at rear of adjoining occupied property with partially hanging cmu fence wall & concrete footing inclu

    Sep 17, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to notify the department of an accident,incident that resultedin a fatality or an injury.a worker was injured while carrying formwork when it tripped and suffered a twisted knee.worker was taken to hosp

    Aug 15, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Note:observed on adjacent building open stair case leading to 2nd floor use as office; that stair have no shed or over head protection, within few feet works on construction site about 10ft above the stairs at

    Jul 29, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Note: worker stripping metal forms about 10ft high concrete wall at exp4 & working area have gap 8'x3' & 12inh deep; 2 plank on it to stand, doing striping work standing on unsafe plank, without safe platform

    Jul 29, 2022

    Resolve
  • Class - 2

    Failure to safe all persons&property&institute safety measures.note:atoi@n14styb@excavation phase i observed plywood door that swings outward onto sw creating hazard to pedestrians&patrons of restaurant from be

    Apr 14, 2022 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to provide approved/accepted construction documents at jobsiteat time of inspection(means of method of removing chipping bedrock)at the time of inspection of a proposed 14 story new building active jobs

    Apr 4, 2022

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments(site safety plan.at the time of inspection of a proposed14 story new building active jobsite,upon review of approved ssp provi

    Apr 4, 2022

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments(sidewalk shed)at the time of inspection of a proposed 14story new building active jobsite,i observed at exp1 existing sws in p

    Apr 4, 2022

    Resolve
  • Class - 2

    Jobsite fence(missing)at the time of inspection of a proposed 14 storynew building active jobsite,i observed at exp4 to adjacent occupied property missing 8'high construction fence.as per rule not indicated on

    Apr 4, 2022

    Resolve
  • Class - 1

    3307.6.4.9 sws obstructing/interrupting physical and visual view of traffic light signs.at the time of inspection of a proposed 14 story newbuilding active jobsite,i observed in exp1 on sidewalk existing sws bl

    Apr 4, 2022 · Penalty $625

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or amendments-s.o.e. plans(slope&shoring piles,2x10 timber lagging section b-b and section l-l) expo 2. at time of inspection at a 14 story nb,i obse

    Mar 16, 2022 · Penalty $625

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection bc3307.7. noted: observed unsecured/out of plumb sidewalk shed scaffold at exposure #4 and broken side fence at exposure #4 (approx 8 ft) leani

    May 21, 2018 · Penalty $800

    Resolve
  • Class - 2

    Failure to maintain temporary construction equipment as per 3307.7. note at time of inspection i observed construction fence in place not maintained. rmdy: comply with code-provide maintenance.

    Apr 25, 2018 · Penalty $400

    Resolve
  • Class - 3

    Work without a permit. at time of inspection. noted: jobsite fence installed with an expired permit #220257754-01-eq-fn 02/25/2014. secured fence. rem: expired permit, renew permit.

    Apr 17, 2018

    Resolve

Complaints

  • Flooring/stairs

    Floor

    Jul 22, 2026 · Apt 504

    Close
  • Water leak

    Slow leak

    Jul 22, 2026 · Apt 504

    Close
  • General

    Ventilation system

    Jul 22, 2026 · Apt 504

    Close
  • Door/window

    Window pane

    Jul 17, 2026 · Apt 1302

    Close
  • General

    Janitor/super

    Jul 17, 2026 · Apt 1302

    Close
  • Heat/hot water

    Apartment only

    Jan 28, 2026 · Apt 1405

    Close
  • Heat/hot water

    Apartment only

    Jan 26, 2026 · Apt 1405

    Close
  • Heat/hot water

    Entire building

    Jan 25, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Jan 24, 2026 · Apt 1803

    Close
  • Door/window

    Door

    Dec 21, 2025 · Apt 1603

    Close
Show 9 more ↓
  • Heat/hot water

    Apartment only

    Dec 6, 2025 · Apt 1505

    Close
  • Plumbing

    Water supply

    Jun 25, 2025 · Apt 801

    Close
  • General

    Ventilation system

    Apr 1, 2025 · Apt 604

    Close
  • Door/window

    Door

    Apr 1, 2025 · Apt 604

    Close
  • Electric

    Power outage

    Mar 24, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Mar 24, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 17, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 12, 2025 · Apt BLDG

    Close
  • Electric

    Power outage

    Jan 12, 2025 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D1)
Year built
2022
Floors
18
Residential units
89
Building area
79,474 ft²
Lot area
20,383 ft²
Zoning
R6
Community board
208
Council district
11
Block / lot
5796 / 127
Assessed value
$6,890,850
Landmark / historic district
No

HPD registration #229000, last renewed Jul 15, 2025.

Questions about 3745 Riverdale Avenue

Who owns 3745 Riverdale Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 3745 Riverdale Avenue LLC.

Does 3745 Riverdale Avenue have violations?

Yes. NYC HPD has recorded 7 housing violations at this property.

Is 3745 Riverdale Avenue rent stabilized?

NYC Department of Finance tax bills listed 75 rent-stabilized units here in 2024 (about 84% of its 89 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 3745 Riverdale Avenue built?

City records list 2022 as the year it was built.

How many apartments are in 3745 Riverdale Avenue?

It has 89 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.