roofy

2324 University Avenue

Bronx, NY 10468BBL 2-03212-0040Map

Owner of record: Uni-Heights Realtors Corp.

2324 University Avenue is a walk-up apartment building built in 1916 in Bronx, 10468. It has 11 residential units across 5 floors. The owner of record is Uni-Heights Realtors Corp.. HPD has recorded 39 housing violations here, most recently on July 1, 2026. 19 of the 39 most recent violations are still open. City tax records listed 2 rent-stabilized apartments here in 2024.

HPD violations
39
DOB violations
6
ECB violations
0
HPD complaints
90

What to know

Concern
4 open Class C

Immediately hazardous issues among recent violations are still open.

Good
Last violation Jul 1, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
2
About 18% of the building's 11 apartments
Down from 3 in 2018

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 39

  • B

    Properly repair with similar material the broken or defective mortar joints at west exterior parapet wall (building front)

    Jul 1, 2026

    Open — Nov certified on time
  • C

    Provide ready access to buildings heating system door locked at boiler room

    Jul 1, 2026

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 1n, 1st story, 1st apartment from north at east

    Jul 1, 2026 · Apt 1N

    Closed — Violation closed
  • B

    Properly repair the source and abate the evidence of a water leak the ceiling in the 1st room from north located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation dismissed
  • B

    Replace the broken or defective water closet in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective porcelain enamel finish by method of reglazing at bathtub in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation dismissed
  • B

    Provide in event of power outage by means of an acceptable mechanical heavy duty lock and latch set at door at building entrance

    Apr 8, 2026

    Open — Invalid certification
  • A

    Paint with light colored paint to the satisfaction of this department all peeling paint surfaces in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation dismissed
  • B

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft ceiling in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north original violation 18773800 issued 08-apr-26 has been upgraded to class b per administrative code 27-2017.3a(3)(a) or (b).

    Apr 8, 2026 · Apt 3N

    Open — Civ14 mailed
  • B

    Remove all obstructions and repair all defects in drain pipe at wash basin in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation dismissed
Show 29 more ↓
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Open — Notice of issuance sent to tenant
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Open — Notice of issuance sent to tenant
  • A

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft ceiling in the bathroom located at apt 3n, 3rd story, 1st apartment from west at north

    Apr 8, 2026 · Apt 3N

    Closed — Violation closed
  • C

    Remove the illegal fastening consisting of unacceptable electronic magnetic locking device installed at building entrance door

    Apr 8, 2026

    Open — Nov sent out
  • B

    Provide heavy duty lock and assembly at building entrance door from street to vestibule at public hall, 1st story

    Jun 28, 2023

    Open — Invalid certification
  • C

    Remove the illegal fastening two motion electromagnetic lock and assembly at public hall, 1st story

    Jun 28, 2023

    Open — Invalid certification
  • C

    Replace or repair the self-closing doors that is missing or defective hinge at vestibule door ( vestibule to 1st sty public hall) at public hall, 1st story

    Jun 28, 2023

    Closed — Violation closed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Jun 28, 2023

    Closed — Violation dismissed
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box at public hall, 1st story

    Jun 28, 2023

    Closed — Violation dismissed
  • B

    Trace and repair the source and abate the visible mold condition... at ceiling approx. 10 sq. ft. in the bathroom located at apt 2n, 2nd story, 1st apartment from north at east

    Apr 25, 2023 · Apt 2N

    Open — First no access to re- inspect violation
  • B

    Trace and repair the source and abate the visible mold condition... at east, west, north and south walls approx. 3 sq. ft. each in the bathroom located at apt 2n, 2nd story, 1st apartment from north at east

    Apr 25, 2023 · Apt 2N

    Open — First no access to re- inspect violation
  • A

    Paint with light colored paint to the satisfaction of this department all walls and ceiling in the bathroom located at apt 2n, 2nd story, 1st apartment from north at east

    Apr 25, 2023 · Apt 2N

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 4, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 18, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 18, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 12, 2018

    Closed — Violation dismissed
  • B

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following minimum of 100 watts as required(light fixture(s) present). at front areaway

    Oct 8, 2017

    Closed — Violation dismissed
  • B

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following minimum of 100 watts as required(light fixture(s) present). at front areaway

    Jul 21, 2017

    Closed — Violation dismissed
  • B

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following minimum required 2oo watts (light fixture present) at front areaway

    Oct 14, 2015

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 5, 2015

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 5, 2015

    Closed — Violation dismissed
  • B

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following a minimum of 200 watts incandescent light .required; light fixture present. at front areaway

    Nov 13, 2014

    Open — Invalid certification
  • B

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following a minimum of 100 watts of incandescent light required.

    Jan 5, 2011

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and walls in the 2nd room from east at south located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment denied
  • B

    Properly repair the broken or defective radiator in the 1st room from north at west located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment denied
  • A

    Replace with new the broken or defective escutcheon plate at riser pipe in the 1st room from north at west located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment granted
  • B

    M/d law abate the nuisance consisting of the ceiling in the 1st room from north at west located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment denied
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the 1st room from north at west located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment denied
  • B

    Trace and repair the source and abate the nuisance consisting of mold ... mildew at the ceiling and walls closet in the 1st room from north at west located at apt 3s, 3rd story, 2nd apartment from north at east

    Oct 24, 2007 · Apt 3S

    Open — Certification postponment denied

DOB building violations · 6

  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 9, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 17, 1993

    Dob violation - dismissed

ECB violations · 0

No ECB violations on record

Complaints

  • Heat/hot water

    Entire building

    Oct 23, 2026 · Apt BLDG

    Open
  • Heat/hot water

    Entire building

    Oct 23, 2026 · Apt BLDG

    Open
  • Heat/hot water

    Entire building

    Oct 23, 2026 · Apt BLDG

    Open
  • Plumbing

    Water supply

    Jun 30, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    May 25, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    May 23, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    May 23, 2026 · Apt BLDG

    Close
  • Plumbing

    Toilet

    Apr 1, 2026 · Apt APT3N

    Close
  • Unsanitary condition

    Mold

    Apr 1, 2026 · Apt APT3N

    Close
  • Unsanitary condition

    Pests

    Dec 4, 2024 · Apt 3N

    Close
Show 40 more ↓
  • Water leak

    Heavy flow

    Aug 4, 2024 · Apt 2N

    Close
  • Electric

    Lighting

    Aug 4, 2024 · Apt 2N

    Close
  • Electric

    Lighting

    Aug 4, 2024 · Apt 2N

    Close
  • Heat/hot water

    Apartment only

    Jun 19, 2023 · Apt 4N

    Close
  • Heat/hot water

    Entire building

    Jun 19, 2023 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jun 18, 2023 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Apr 22, 2023 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Apr 1, 2023 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 15, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Oct 3, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Oct 3, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Dec 17, 2020 · Apt 3N

    Close
  • Heat/hot water

    Apartment only

    Aug 25, 2020 · Apt 4S

    Close
  • Paint/plaster

    Ceiling

    Jul 3, 2020 · Apt 4S

    Close
  • Unsanitary condition

    Mold

    Jul 3, 2020 · Apt 4S

    Close
  • Plumbing

    Radiator

    Jul 3, 2020 · Apt 4S

    Close
  • Heat/hot water

    Entire building

    May 5, 2020 · Apt 1N

    Close
  • Plumbing

    Bathtub/shower

    Feb 25, 2020 · Apt 3N

    Close
  • Heat/hot water

    Apartment only

    Feb 25, 2020 · Apt 3N

    Close
  • Heat/hot water

    Entire building

    Nov 7, 2019 · Apt 4G

    Close
  • Heat/hot water

    Apartment only

    Nov 22, 2018 · Apt 3N

    Close
  • Heat/hot water

    Entire building

    Feb 15, 2015 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Nov 2, 2014 · Apt 1S

    Close
  • Heat/hot water

    Entire building

    Apr 4, 2014 · Apt 2S

    Close
  • Heating

    Heat related

    Feb 13, 2014 · Apt 2N

    Close
  • Heating

    Heat related

    Sep 11, 2013 · Apt 2N

    Close
  • Heating

    Heat related

    Oct 12, 2012 · Apt 2S

    Close
  • Heating

    Heat related

    Apr 24, 2012 · Apt 2S

    Close
  • Heating

    Heat related

    Apr 24, 2012 · Apt 2S

    Close
  • Heating

    Heat related

    Feb 12, 2012 · Apt 4N

    Close
  • Heating

    Heat related

    Jan 3, 2012 · Apt 2N

    Close
  • Heating

    Heat related

    Dec 29, 2011 · Apt 4N

    Close
  • Heating

    Heat related

    Dec 10, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Dec 10, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Nov 22, 2011 · Apt 3N

    Close
  • Heating

    Heat related

    Apr 18, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Apr 17, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Apr 12, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Apr 3, 2011 · Apt 2N

    Close
  • Heating

    Heat related

    Apr 2, 2011 · Apt 2N

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
1916
Floors
5
Residential units
11
Building area
17,070 ft²
Lot area
4,750 ft²
Zoning
R7-1
Community board
207
Council district
14
Block / lot
3212 / 40
Assessed value
$435,600
Landmark / historic district
No

HPD registration #215702, last renewed Jul 17, 2026.

Questions about 2324 University Avenue

Who owns 2324 University Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Uni-Heights Realtors Corp..

Does 2324 University Avenue have violations?

Yes. NYC HPD has recorded 39 housing violations at this property.

Is 2324 University Avenue rent stabilized?

NYC Department of Finance tax bills listed 2 rent-stabilized units here in 2024 (about 18% of its 11 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 2324 University Avenue built?

City records list 1916 as the year it was built.

How many apartments are in 2324 University Avenue?

It has 11 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.