roofy

1035 Woodycrest Avenue

Bronx, NY 10452BBL 2-02512-0069Map

Owner of record: Woodycrest Avenue Associates

1035 Woodycrest Avenue is an elevator apartment building built in 1929 in Bronx, 10452. It has 62 residential units across 6 floors. The owner of record is Woodycrest Avenue Associates. HPD has recorded 839 housing violations here, most recently on October 1, 2026. 32 of the 50 most recent violations are still open. City tax records listed 62 rent-stabilized apartments here in 2024.

HPD violations
839
DOB violations
40
ECB violations
57
HPD complaints
1,534

What to know

Concern
12 open Class C

Immediately hazardous issues among recent violations are still open.

Watch
Last violation Oct 1, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
62
About 100% of the building's 62 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 839

  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • B

    Trace and repair the source and abate the visible mold condition... greater than 10sq.ft but less than 30 sq ft at south wall in the 3rd room from east located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Notice of issuance sent to tenant
  • B

    Trace and repair the source and abate the visible mold condition... greater than 10sq.ft but less than 30 sq ft at east wall in the 1st room from east at north located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Notice of issuance sent to tenant
  • B

    Trace and repair the source and abate the visible mold condition... greater than 10sq.ft but less than 30 sq ft at south wall in the bathroom located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Notice of issuance sent to tenant
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations additional required in the entire apartment located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • A

    Paint metal in accordance with dept. regulation heat riser pipe at north wall in the bathroom located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective light fixture at ceiling in the bathroom located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • B

    Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules additional required in the entire apartment located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • B

    M/d law abate the nuisance consisting of defective vinyl floor tile in the 3rd room from east located at apt 3a, 3rd story, 2nd apartment from north at east , section ''south''

    Oct 1, 2026 · Apt 3A

    Open — Nov sent out
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
Show 40 more ↓
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures at electrical outlet at south wall in the bathroom located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures electrical fixtures at ceiling in the bathroom located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures at electrical outlet at south wall in the kitchenette located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling in the 2nd room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 2nd room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Properly repair with similar material the broken or defective floor tile in the 2nd room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures at electrical outlet at east, north, south, and west walls in the 1st room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures elecrical fixtures at ceiling in the 1st room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures at electrical outlet at east,north, and west walls in the 2nd room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • B

    Provide a safe and adequate supply of electric service to the fixtures electrical fixtures at ceiling in the 2nd room from north at east located at apt 6l, 6th story, 3rd apartment from north at east , section ''f-l'', 1st from west at north

    Aug 28, 2026 · Apt 6L

    Open — Civ14 mailed
  • C

    Provide ready access to buildings heating system boiler room lock at public hall, 1st story

    Aug 20, 2026

    Open — Nov certified on time
  • A

    Post a proper notice regarding rent stabilization law, in a form approved by the commissioner, in a conspicuous location within the common area at the buildings entrance. for more information about signage requirements, please visit: https://www.nyc.gov/site/hpd/services-and-information/required-signage.page

    Aug 20, 2026

    Open — Nov certified on time
  • C

    Provide adequate supply of hot water for the fixtures inadequate hot water supply at all plumbing fixtures in the entire apartment located at apt 5g, 5th story, 2nd apartment from south at west , section ''north''

    Aug 20, 2026 · Apt 5G

    Open — Civ14 mailed
  • C

    Provide adequate supply of cold water for the fixtures at fixtures in bathroom and kitchen in the entire apartment located at apt 5g, 5th story, 2nd apartment from south at west , section ''north''

    Aug 20, 2026 · Apt 5G

    Open — Civ14 mailed
  • C

    Provide adequate supply of hot water for the fixtures .. in the entire apartment located at apt 5g, 5th story, 2nd apartment from south at west , section ''north''

    Aug 11, 2026 · Apt 5G

    Open — Nov sent out
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 5g, 5th story, 2nd apartment from south at west , section ''north''

    Aug 11, 2026 · Apt 5G

    Open — Notice of issuance sent to tenant
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 5g, 5th story, 2nd apartment from south at west , section ''north''

    Aug 11, 2026 · Apt 5G

    Open — Notice of issuance sent to tenant
  • C

    Provide ready access to buildings heating system door locked at public hall, 1st story

    Aug 11, 2026

    Open — Nov sent out
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 1g, 1st story, 1st apartment from south at west

    Jan 28, 2026 · Apt 1G

    Closed — Violation dismissed
  • C

    Provide hot water at all hot water fixtures in the 3rd room from east located at apt 1g, 1st story, 1st apartment from south at west

    Jan 28, 2026 · Apt 1G

    Closed — Violation dismissed
  • C

    Provide ready access to buildings heating system doors locked at boiler room

    Jan 28, 2026

    Closed — Violation dismissed
  • C

    Provide an adequate supply of heat for the apartment in the 3rd room from east located at apt 1g, 1st story, 1st apartment from south at west

    Jan 28, 2026 · Apt 1G

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective vinyl floor tiles in the kitchen located at apt 2h, 2nd story, 1st apartment from west at north

    Nov 26, 2025 · Apt 2H

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 1c, 1st story, 1st apartment from east at south , section ''south''

    Apr 14, 2025 · Apt 1C

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective lower sash spring balances at window in the bathroom located at apt 1c, 1st story, 1st apartment from east at south , section ''south''

    Apr 14, 2025 · Apt 1C

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 1c, 1st story, 1st apartment from east at south , section ''south''

    Apr 14, 2025 · Apt 1C

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective (defective spring loaded hinges) in the entrance located at apt 1c, 1st story, 1st apartment from east at south , section ''south''

    Apr 14, 2025 · Apt 1C

    Closed — Violation dismissed
  • B

    Repair the leaky and/or defective faucets at bathtub in the bathroom located at apt 1c, 1st story, 1st apartment from east at south , section ''south''

    Apr 14, 2025 · Apt 1C

    Closed — Violation dismissed
  • C

    Properly repair with similar material the broken or defective fire retardent material at public hall 6th story ceiling and at bulkhead north 2 at 2nd public hall bulkhead from north, 6th story

    Mar 5, 2025

    Open — Nov sent out
  • C

    Repair the roof so that it will not leak over and at bulkhead north 2 at 2nd public hall bulkhead from north, 6th story

    Mar 5, 2025

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective glass panes at the vestibule door (vestibule to 1st story public hall) , 1st story

    Oct 2, 2024

    Closed — Violation dismissed
  • B

    M/d law abate the nuisance consisting of plexi glass panes at the vestibule door (vestibule to 1st story public hall) , 1st story

    Oct 2, 2024

    Closed — Violation dismissed
  • A

    Provide a mirror in self-service elevator arranged so as to enable a person entering, to view inside of elevator number 1

    Oct 2, 2024

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective fire retardant materials at east wall at public hall, 6th story at south section

    Sep 29, 2024

    Closed — Violation dismissed
  • B

    M/d law abate the nuisance consisting of cracked and broken vinyl floor tiles [creating trip hazard] in the 2nd room from east located at apt 6l, 6th story, 3rd apartment from north at east , section ''north''

    Sep 29, 2024 · Apt 6L

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at building entrance door [from courtyard to vestibule] at 2nd building entrance from north , 1st story

    Sep 29, 2024

    Closed — Violation closed
  • C

    Properly repair or replace the broken or defective latch set at building entrance door [from courtyard to vestibule] at 1st building entrance from north , 1st story

    Sep 29, 2024

    Open — Not complied with
  • C

    Replace or repair the self-closing doors that is missing or defective latch set at building entrance door [from courtyard to vestibule] at 1st building entrance from north , 1st story

    Sep 29, 2024

    Closed — Violation closed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 6l, 6th story, 3rd apartment from north at east , section ''north''

    Sep 29, 2024 · Apt 6L

    Closed — Violation dismissed

DOB building violations · 40

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2025

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2025

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2025

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2025

    Dob violation - dismissed
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9c technical report by 2/21/2024

    Feb 22, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 24, 2024

    Dob violation - dismissed
  • Construction other optional

    Due to fire

    Mar 7, 2020

    Dob violation - dismissed
  • Construction other optional

    Due to fire

    Mar 7, 2020

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 4, 2019

    Dob violation - resolved
Show 30 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 12, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 28, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    Cease use

    Aug 7, 2018

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 19, 2017

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 29, 2015

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 1, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 16, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 31, 2011

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 9, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 9, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 9, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 4, 2008

    Dob violation - resolved
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 20, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 9, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 1, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 25, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 12, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 18, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    2p1088

    Feb 14, 2001

    Dob violation - resolved
  • Construction other optional

    C-construction other optional

    Oct 2, 2000

    Dob violation - dismissed
  • Elevator elevatorrequired

    2p1088

    Apr 28, 1999

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 13, 1997

    Dob violation - active
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 13, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 17, 1993

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 2, 1990

    Dob violation - resolved
  • Elevator elevatorrequired

    74-provide access to overhead

    Mar 15, 1990

    Dob violation - resolved
  • Elevator elevatorrequired

    (51) remove noise from main machine (37) cover

    Dec 12, 1988

    Dob violation - resolved

ECB violations · 57

  • Class - 2

    1) there is a hole in the cab (near the mirror) (2.14.1.2.4) 2) the mirror in the car is not functioning properly. replace it (bc 3001.6) 3) the security camera has been vandalize (sprayed with black paint) (8.

    May 5, 2026

    Resolve
  • Class - 1

    Failure to maintain bldg exterior facade and appurtenances. note: at time of inspection, i observed exp #1 east-(1) cracked brick at parapetlevel multi loc. (2)cracked terracotta windowsills and water table mul

    Mar 7, 2026 · Penalty $5,000

    Active
  • Class - 2

    Failure to submit an acceptable required cycle 8c and 9c report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #912553. agg2 history of noncomp

    Apr 8, 2025 · Penalty $10,000

    Active
  • Class - 2

    At time of inspection observed sws remain on site however permit #x0757007 has been expired on 09/12/2024., renew permit

    Nov 25, 2024 · Penalty $625

    Active
  • Class - 1

    W/o a permit. noted: at 5th & 6th flrs - electrical wiring installed at k line apts: 220v lines for stoves; 110v lines for addl't lights & outlets., obtain permit

    Nov 14, 2024

    Resolve
  • Class - 2

    W/o a permit. noted: at 5th & 6th flrs - water & waste lines installed at k line apts for addl't 3 pc bthrms; residential sinks at kitchen area., obtain all permits

    Nov 14, 2024

    Resolve
  • Class - 1

    Contrary to dob/official records which indicates 11 apts at 6th flr: at time of inspection - apt 6k observed sub-divided & an addl't/12th apt created 6l with 3 pc bthrm; kitchen with electric stove, residential

    Nov 14, 2024 · Penalty $625

    Resolve
  • Class - 1

    Contrary to dob/official records which indicates 11 apts at 5th flr: at time of inspection - apt 5k observed sub-divided & an addl't/12th apt created 5m with 3 pc bthrm; kitchen with electric stove, residential

    Nov 14, 2024 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner. noted: at time of inspection - observed various thanksgiving blowup items & decorations, e-bike stored at public hallway creating a egress/clear passage ob

    Nov 14, 2024

    Resolve
  • Class - 1

    W/o a permit. noted: 1) at exposure 1 north courtyard front entrance; a fire escape erected erected 5th flr to 2nd flr, 2) at 5th & 6th flrs at k line apts - full height partition walls erected to sub-divide ap

    Nov 14, 2024

    Resolve
Show 40 more ↓
  • Class - 1

    During electrical inspection of application x08054558 on 11/16/23 @ 5:00 pm i observed in the basement exposed energized conductors thhn and flexible cord that was that was cut and hardwired to provide power fo

    Nov 16, 2023 · Penalty $800

    Resolve
  • Class - 1

    During electrical inspection of application x08054558 on 11/16/23 @ 5:00 pm i observed in the basement exposed energized conductors thhn and flexible cord that was that was cut and hardwired to provide power fo

    Nov 16, 2023

    Resolve
  • Class - 2

    Failure to submit an acceptable required cycle 8c report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#812553.agg2 history of noncompliance on

    Oct 19, 2022 · Penalty $10,000

    Active
  • Class - 1

    Failure to maintain exterior building facade and appurtenances.note:observed at exp1(east)cracked brick masonry below fire escapes,cracked terra cotta and multiple loose objects on window sills.exp4(north)crack

    Feb 23, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    In apt 3f, in rear room, excessive amount of construction debris, consisting of wood scraps, steel stud cutoffs, large plastic bags has accumulated. pile approximately 8' x 8' x 4', maintain adequate constructi

    Jan 12, 2021

    Resolve
  • Class - 2

    Failure to submit an acceptable required cycle 8c report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#812553.rem:submit acceptable required t

    Feb 13, 2020 · Penalty $1,250

    Active
  • Class - 2

    Provide missing in case of fire signs. replace damaged 1st floor and basement door buck. missing certificate. replace cab mirror. replace hoistway door gibs where needed. secure hoistway door gibs where needed.

    Sep 8, 2019 · Penalty $655

    Active
  • Class - 2

    99b05 cat 1 is unsatisfacotry.

    Oct 21, 2018 · Penalty $625

    Resolve
  • Class - 1

    97x17 rmdy device is still under cease use and not lifted repair ad contact nycdob for reinspection.

    Sep 13, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    (97-x-17)restore elevator to service and file for test

    Aug 27, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Cu-01x10,39q03,60q03,37x10,37d06,37q03,67x10,70o02,71i11,76m07 (cease use item 01x10-repair emergenc stop switch in car); 39q03-install guard for right top of car; 37x10-repair light in overhead; 37d06-secure

    Nov 5, 2014 · Penalty $1,000

    Resolve
  • Class - 2

    15i11,21q03,35q03,39g03,60q03,67x10,70o02,71x10,71q03,76m07,77m11.21q03 install cover for bsmt & 1st fl hoistway door interlock.36q03 install covers for elect boxes in shaftway.39q03 install guard for light top

    Jun 30, 2014 · Penalty $2,500

    Resolve
  • Class - 2

    59d06,21m07,17m07,13f10,15m07,70o02,68b07,100l10,29b10,32h10: 59d16;secure brake pins. 21m07;provide covers. 17m07;provide missing door gibs15m07;provide post cert frame card. 68b07;provide proper information i

    May 18, 2012 · Penalty $250

    Resolve
  • Class - 2

    Failure to file an acceptable 6th round technical report in compliancew/code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dob's rules & regulations.

    Jan 15, 2012 · Penalty $2,000

    Resolve
  • Class - 2

    13i11,15i11,24x10,35q03,36q03,21q03,37p16,39x03,39q03,60q03,67x10,68b07, 71i11,100m7. 24x10- repair position indicator in car. 35q- install cover for electrical box top of car.36q- install covers for electrical

    Oct 4, 2011 · Penalty $250

    Resolve
  • Class - 2

    Failure to file an acceptable 6th round technical report in compliancew/code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dob rules & regulations.

    Apr 15, 2011 · Penalty $2,000

    Resolve
  • Class - 1

    Sec. 3314.6.2 no protection of ropes &/or cables around sharp bends,corners ropes shall not be made fast to sharp objects or surfaces. tie backs for c-hooks around bulkhead no protection. remedy: comply w/code.

    Dec 8, 2010 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations rem:

    Jul 12, 2010 · Penalty $2,000

    Resolve
  • Class - 2

    13i10,37i10,37x10,37q03,40r09,60q03,67x10,68m07,70o02,71x10,71q03,77m11. 37i10-repair, skylight in overhead. 37x10-repair light in overhead sheave rm. 37q03-install guard for light in over head sheave rm. 40r09

    Jun 23, 2010 · Penalty $250

    Resolve
  • Class - 2

    Failure to maintain exterior of building.east elevation observe step cracks and displaced in parapet facade;cracks and deteriorating in lintel facade;blocks of wood under a/c unit(north).north elevation observe

    May 18, 2010 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to file cofc for vio's#34808255p,34808254n.rem:file cofc

    Feb 11, 2010 · Penalty $800

    Resolve
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/code provisions:periodic inspection of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations

    Nov 27, 2009 · Penalty $800

    Resolve
  • Class - 1

    Work w/o permit. work noted: a loft was erected at rear of stove at 1st flr. the height from flr to ceiling is approx 16'-0",from the middle to rear of stove the loft was created for storage. remedy: obtain a

    Oct 15, 2009

    Resolve
  • Class - 2

    Failure to maintain bldg walls & appurtenances. (1) objects were foundunder a.c. units at various floors at east (front) & west elevations.(ii) loose hanging alum window molding was found at 2/f at north of eas

    Oct 7, 2009 · Penalty $250

    Resolve
  • Class - 2

    Failure to comply w/an order from the commissioner to file a cofc w/ dob for nov #34743800r issued 4/25/09 for failure to maintain unsupported window a.c units remedy:file cofc

    Sep 16, 2009 · Penalty $800

    Resolve
  • Class - 1

    Failure to maintain exterior observed:located thru-out bldg unsupportedor improperly supported window a/c units either no support or support using wood blocks used see prior nov # 34743800r issued 04/25/09 reme

    Sep 16, 2009 · Penalty $1,000

    Resolve
  • Class - 1

    Failure to maintain exterior wall observed:at side of bldg located above 1025 woodycrest ave spalling brick wall located at 3 fl bldg pourous bldg seal remedy:repair/maintain wall

    Sep 16, 2009 · Penalty $1,000

    Resolve
  • Class - 1

    97x10.97x10 1rcny 11-02 only elevator in bldg out of service restore to service (hazardous)

    Jun 17, 2009 · Penalty $1,000

    Resolve
  • Class - 2

    13i10.21b6.70o2.39o2.11x10. 13i10 repair damaged emergency lighting inside elevator 21b6 properly secure all interlocks covers and replace missing covers 11x10 return service to bsmt from car station

    Jun 9, 2009 · Penalty $250

    Resolve
  • Class - 2

    11x10, 100x10. 11x10- return service to lobby car station button. 100x10- repair emergency phone inside elevator.

    May 11, 2009 · Penalty $250

    Resolve
  • Class - 1

    Failure to maintain refer to prior vecb #36483593l 3 of 17 window a/c units improperly installed blocks of wood sued supported outside window. additionally:: fire escape obstructed w/ shopping cart collapseable

    Apr 25, 2009 · Penalty $1,000

    Resolve
  • Class - 2

    Failure to submit an acceptable sixth round technical report in compliance w/code provisions:periodic inspection of exterior walls and appurtenances as required by article 28.302 & the dob rules & regulations

    Jan 30, 2009 · Penalty $800

    Resolve
  • Class - 1

    Failure to maintain exterior bldg east elevation shows blocks of wood & bricks under air condition improperly installed.west elevation show blocks of wood under a/c unit ,also projecting loose flower pot from

    Sep 23, 2008 · Penalty $1,000

    Resolve
  • Class - 1

    Failure to provide sidewalk shed where required on the east elevation.remedy:provide sidewalk shed protect the public repair & replace all damage facade make area safe.

    Sep 23, 2008 · Penalty $4,800

    Resolve
  • Hazardous

    Failed to mntn ext.bldg,east elevation shows deteriorating&broken lintel facade;blocks of wood&bricks under ac units,strg objects on fire scape landing,broken stairway entrance of bldg 1035&1045.west elevation

    Feb 14, 2008 · Penalty $800

    Resolve
  • Non-hazardous

    B4a,24b,44a,50a,b. note:44a need steam gauge 300psi calibrated 50a-boiler uper casing & insulation defective 50b-remove threads from safety relief valve discharge pipe at end note:24b-need boiler switch (rc)

    Jul 6, 2007

    Resolve
  • Non-hazardous

    17b10 4th floor hoistway door needs two gibs & properly secured.

    Aug 15, 2006 · Penalty $350

    Resolve
  • Non-hazardous

    60t15/41h11/17h11/14m7/28b1/7q3/10h11/5k11/21q3/52h14/71k11/36x11/32o2/33o2/35o2/38o2/39o2/66o2/67o2/68o2/69o2/71o2/ 41- replace "p" relay. 17-base & lobby 3rd floor. 28-cab door not fully open. 5- replace cab

    Apr 6, 2005 · Penalty $180

    Resolve
  • Non-hazardous

    Failure to provide elevator landing sign that shall read"in case of fire use stairs unless otherwise instructed"at the elevator's bank on flr 2 to 6.failure to provide 3-inch minimum high alphabetic letter of

    Nov 17, 2003 · Penalty $400

    Resolve
  • Non-hazardous

    62o02/ 31o02/ 63o02/ 64o02/ 52y14/ 54o02/ 19q03/ 17h12/ 16l01/22x11/ 19- covers missing 3rd & 4th floors 17 - basement lobby and 2nd floor 3rd floor gribs loose 22 - in halls and cab 16 - lobby h/d not

    Nov 1, 2002

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Oct 18, 2026 · Apt BLDG

    Close
  • Flooring/stairs

    Floor

    Sep 29, 2026 · Apt 3A

    Close
  • Unsanitary condition

    Mold

    Sep 29, 2026 · Apt 3A

    Close
  • Electric

    Power outage

    Aug 27, 2026 · Apt 6L

    Close
  • Unsanitary condition

    Pests

    Aug 21, 2026 · Apt 4E

    Close
  • Water leak

    Damp spot

    Aug 21, 2026 · Apt 4E

    Close
  • Unsanitary condition

    Pests

    Aug 21, 2026 · Apt 4E

    Close
  • Plumbing

    Water supply

    Aug 21, 2026 · Apt 4E

    Close
  • Plumbing

    Water supply

    Aug 20, 2026 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Aug 20, 2026 · Apt BUILDI

    Close
Show 40 more ↓
  • Plumbing

    Water supply

    Aug 20, 2026 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Aug 20, 2026 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Aug 20, 2026 · Apt 6F

    Close
  • Plumbing

    Water supply

    Aug 19, 2026 · Apt 6D

    Close
  • Plumbing

    Water supply

    Aug 19, 2026 · Apt 5G

    Close
  • Plumbing

    Water supply

    Aug 19, 2026 · Apt 6B

    Close
  • Plumbing

    Water supply

    Aug 14, 2026 · Apt 5G

    Open
  • Plumbing

    Water supply

    Aug 10, 2026 · Apt 5G

    Close
  • Plumbing

    Water supply

    Aug 7, 2026 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Jul 1, 2026 · Apt 6B

    Close
  • Unsanitary condition

    Pests

    Jun 22, 2026 · Apt 5G

    Close
  • Heat/hot water

    Entire building

    Feb 23, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Feb 22, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Feb 13, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Feb 11, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Feb 4, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Feb 3, 2026 · Apt 5G

    Close
  • Heat/hot water

    Entire building

    Feb 1, 2026 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Jan 29, 2026 · Apt 1G

    Close
  • Heat/hot water

    Entire building

    Jan 27, 2026 · Apt 1G

    Close
  • Heat/hot water

    Apartment only

    Jan 22, 2026 · Apt 5G

    Close
  • Unsanitary condition

    Pests

    Oct 15, 2025 · Apt 2H

    Close
  • Unsanitary condition

    Pests

    Oct 15, 2025 · Apt 2H

    Close
  • Unsanitary condition

    Pests

    Sep 24, 2025 · Apt 2B

    Close
  • Flooring/stairs

    Floor

    Jul 27, 2025 · Apt 6L

    Close
  • Paint/plaster

    Wall

    Jul 27, 2025 · Apt 6L

    Close
  • Water leak

    Slow leak

    Jul 27, 2025 · Apt 6L

    Close
  • Appliance

    Electric/gas range

    Jul 27, 2025 · Apt 6L

    Close
  • Door/window

    Window frame

    Jul 27, 2025 · Apt 6L

    Close
  • Plumbing

    Water supply

    Jun 24, 2025 · Apt 5C

    Close
  • Plumbing

    Water supply

    Jun 23, 2025 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Jun 23, 2025 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Jun 23, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Apr 12, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Mar 4, 2025 · Apt 5G

    Close
  • Heat/hot water

    Entire building

    Mar 3, 2025 · Apt 5G

    Close
  • Heat/hot water

    Entire building

    Mar 2, 2025 · Apt 5G

    Close
  • Heat/hot water

    Apartment only

    Jan 21, 2025 · Apt 5GFLOO

    Close
  • Heat/hot water

    Apartment only

    Jan 21, 2025 · Apt 5GFLOO

    Close
  • Heat/hot water

    Entire building

    Jan 6, 2025 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
1929
Floors
6
Residential units
62
Building area
72,000 ft²
Lot area
16,268 ft²
Zoning
R7-1
Community board
204
Council district
16
Block / lot
2512 / 69
Assessed value
$1,641,600
Landmark / historic district
No

HPD registration #211768, last renewed Sep 3, 2025.

Questions about 1035 Woodycrest Avenue

Who owns 1035 Woodycrest Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Woodycrest Avenue Associates.

Does 1035 Woodycrest Avenue have violations?

Yes. NYC HPD has recorded 839 housing violations at this property.

Is 1035 Woodycrest Avenue rent stabilized?

NYC Department of Finance tax bills listed 62 rent-stabilized units here in 2024 (about 100% of its 62 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 1035 Woodycrest Avenue built?

City records list 1929 as the year it was built.

How many apartments are in 1035 Woodycrest Avenue?

It has 62 residential units and 65 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.