1255 Webster Avenue is a walk-up apartment building built in 1917 in Bronx, 10456. It has 29 residential units across 6 floors. The owner of record is 1251-55 Webster Ave. LLC. HPD has recorded 452 housing violations here, most recently on April 18, 2026. City tax records listed 28 rent-stabilized apartments here in 2024.

HPD violations
452
DOB violations
8
ECB violations
4
HPD complaints
652

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Apr 18, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
28
About 97% of the building's 29 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 452

  • A

    Properly repair or replace the broken or defective base cabinet drawer at east in the kitchen located at apt d5, 4th story, 2nd apartment from north at east

    Apr 18, 2026 · Apt D5

    Closed — Violation dismissed
  • A

    § 53, 187, 231 m/d law and department rules and regulations. provide a shoe properly secured to bottom of string of dropladder at north at fire escape

    Apr 18, 2026

    Closed — Violation dismissed
  • B

    Replace the broken or defective eroding metal at bath tub in the bathroom located at apt d3, 4th story, 1st apartment from east at south , section ''1255''

    Feb 12, 2026 · Apt D3

    Closed — Violation dismissed
  • B

    Refit window upper sash in the 1st room from east at south located at apt b2, 2nd story, 2nd apartment from north at east , section ''1255''

    Feb 12, 2026 · Apt B2

    Closed — Violation dismissed
  • B

    Refit door in the 1st room from east at north located at apt b2, 2nd story, 2nd apartment from north at east , section ''1255''

    Feb 12, 2026 · Apt B2

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective wood floor in the 1st room from east at north located at apt b2, 2nd story, 2nd apartment from north at east , section ''1255''

    Feb 12, 2026 · Apt B2

    Closed — Violation dismissed
  • B

    Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective located at apt a3, 1st story, 1st apartment from south at west , section ''1255''

    Feb 12, 2026 · Apt A3

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective mortise lock at entrance door to apartment located at apt b2, 2nd story, 2nd apartment from north at east , section ''1255''

    Feb 12, 2026 · Apt B2

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt b2, 2nd story, 2nd apartment from north at east , section ''1255''

    Feb 12, 2026 · Apt B2

    Closed — Violation dismissed
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective located at apt a3, 1st story, 1st apartment from south at west , section ''1255''

    Feb 12, 2026 · Apt A3

    Closed — Violation dismissed
Show 40 more ↓
  • A

    Paint with light colored paint to the satisfaction of this department the ceiling, floor in the 2nd room from north at east located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • A

    Paint metal in accordance with dept. regulation the 1st riser from west at north wall in the 1st room from north located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • A

    Paint with light colored paint to the satisfaction of this department the ceiling in the 1st room from north located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • C

    Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) ceiling, floor in the 2nd room from north at east located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation closed
  • C

    Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) ceiling, 1st riser from west at north wall in the 1st room from north located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of furniture obstructing egress to fire escape window in the 2nd room from east located at apt a3, 1st story, 1st apartment from south at west

    Apr 9, 2024 · Apt A3

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at apartment entrance door in the entire apartment located at apt a3, 1st story, 1st apartment from south at west

    Apr 9, 2024 · Apt A3

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective door handle in the bathroom located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • A

    Paint metal in accordance with dept. regulation the steam riser in the bathroom located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective door closet in the 1st room from east at south located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective spring balance at lower window sash in the 1st room from east at south located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective wood floor in the 1st room from east at north located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Repair or replace the smoke detector missing in the entire apartment located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment located at apt b2, 2nd story, 2nd apartment from north at east

    Apr 9, 2024 · Apt B2

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective fire retardant material at ceiling at public hall, 3rd story

    Apr 9, 2024

    Closed — Violation dismissed
  • A

    Paint with light colored paint to the satisfaction of this department at ceiling at public hall, 6th story

    Apr 9, 2024

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective fire retardant material at ceiling at public hall, 6th story

    Apr 9, 2024

    Closed — Violation dismissed
  • A

    Paint with light colored paint to the satisfaction of this department at ceiling in the vestibule , 1st story

    Apr 9, 2024

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective fire retardant material at ceiling in the vestibule , 1st story

    Apr 9, 2024

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective wood floor in the 2nd room from north at east located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • A

    Provide electrical outlet switch cover at north wall in the kitchen located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective porcelain enamel glaze of the bathtub in the bathroom located at apt d3, 4th story, 1st apartment from east at south

    Apr 9, 2024 · Apt D3

    Closed — Violation dismissed
  • A

    Paint with light colored paint to the satisfaction of this department all peeling paint surfaces in the 1st room from east at south, the bathroom located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation dismissed
  • A

    Paint metal in accordance with dept. regulation the 1st riser from west at north wall, 1st radiator from west at north wall in the 2nd room from east at south located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color the north wall, east wall, west wall, ceiling in the 1st room from east at north located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation dismissed
  • A

    Paint metal in accordance with dept. regulation the 1st radiator from north at east wall in the 1st room from east at north located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation dismissed
  • C

    Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st radiator from north at east wall, east wall in the 4th room from east located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation closed
  • C

    Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st window frame from south at west wall in the 2nd room from east at south located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation closed
  • C

    Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st closet from south at west wall door, 1st closet from south at west wall door frame, 1st window frame from north at east wall, 2nd window frame from north at east wall in the 1st room from east at north located at apt b1, 2nd story, 1st apartment from north at east

    Apr 4, 2024 · Apt B1

    Closed — Violation closed
  • C

    M/d law abate the nuisance consisting of all hot water fixtures exceeding over 130 degrees in the entire apartment located at apt d2, 4th story, 2nd apartment from north at east

    Jan 17, 2024 · Apt D2

    Closed — Violation dismissed
  • C

    Provide an adequate supply of heat for the apartment in the entire apartment located at apt d2, 4th story, 2nd apartment from north at east

    Jan 17, 2024 · Apt D2

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective buzzer and return voice intercom system from the building entrance door to the panel at south wall in the foyer located at apt b1, 2nd story, 1st apartment from north at east

    Jan 10, 2024 · Apt B1

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective light fixture at the ceiling in the 3rd room from east located at apt b1, 2nd story, 1st apartment from north at east

    Jan 10, 2024 · Apt B1

    Closed — Violation dismissed
  • A

    Trace and repair the source and abate the visible mold condition... at the ceiling in the bathroom located at apt b1, 2nd story, 1st apartment from north at east

    Jan 10, 2024 · Apt B1

    Closed — Violation dismissed

DOB building violations · 8

  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2019 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 29, 2017

    Dob violation - dismissed
  • Immediate emergency anythingoptional

    Install approx 100 linear feet of sidewalk shed along exposure #1 to safeguard public and property

    Sep 8, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 9, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 17, 1993

    Dob violation - dismissed

ECB violations · 4

  • Class - 2

    Failure to comply with the commissioners order contained in summons/violation#35263807n issued on 09/07/17 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.observed at parapet level

    Oct 31, 2017 · Penalty $800

    Resolve
  • Class - 1

    Failure to maintain bldg walls or appurtenances. noted: at time of inspection i observed at parapet level at exp4 a crack in stucco an apprx 4' x 6' of defective stucco with parapet leaning in towards roof with

    Sep 7, 2017 · Penalty $1,000

    Resolve
  • Class - 2

    (36)as per class 254-36, boiler not register as per dob records "correct all violation conditions & submit a c of c".

    Feb 22, 2017 · Penalty $500

    Resolve
  • Class - 2

    B254,39,50,50a: complaint 2139831: 50 burner must be cleaned and ajdjusted, 50a excessive soot on boiler.

    May 14, 2010 · Penalty $1,250

    Resolve

Complaints

  • Water leak

    Slow leak

    Sep 5, 2026 · Apt D

    Close
  • General

    Cabinet

    Apr 16, 2026 · Apt D5

    Close
  • Unsanitary condition

    Pests

    Apr 16, 2026 · Apt D5

    Close
  • Heat/hot water

    Apartment only

    Jan 20, 2024 · Apt B1

    Close
  • Heat/hot water

    Apartment only

    Jan 15, 2024 · Apt D2

    Close
  • Heat/hot water

    Entire building

    Jan 15, 2024 · Apt BLDG

    Close
  • Plumbing

    Toilet

    Dec 10, 2023 · Apt D5

    Close
  • Water leak

    Heavy flow

    Dec 10, 2023 · Apt D5

    Close
  • Heat/hot water

    Apartment only

    Dec 4, 2023 · Apt C1

    Close
  • Door/window

    Door

    Dec 27, 2022 · Apt F5

    Close
Show 40 more ↓
  • General

    Cabinet

    Dec 27, 2022 · Apt F5

    Close
  • Door/window

    Window frame

    Dec 27, 2022 · Apt F5

    Close
  • Flooring/stairs

    Floor

    Dec 27, 2022 · Apt F5

    Close
  • Plumbing

    Toilet

    Dec 27, 2022 · Apt F5

    Close
  • Plumbing

    Basin/sink

    Dec 27, 2022 · Apt F5

    Close
  • Unsanitary condition

    Pests

    Dec 27, 2022 · Apt F5

    Close
  • Appliance

    Electric/gas range

    Nov 16, 2022 · Apt D2

    Close
  • Unsanitary condition

    Pests

    Nov 10, 2022 · Apt D5

    Close
  • Water leak

    Damp spot

    Nov 10, 2022 · Apt D5

    Close
  • Unsanitary condition

    Sewage

    May 24, 2022 · Apt E5

    Close
  • Heat/hot water

    Entire building

    Dec 20, 2020 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Dec 1, 2020 · Apt C2

    Close
  • Paint/plaster

    Ceiling

    Dec 1, 2020 · Apt C2

    Close
  • Appliance

    Electric/gas range

    Dec 1, 2020 · Apt C2

    Close
  • General

    Cabinet

    Dec 1, 2020 · Apt C2

    Close
  • Plumbing

    Bathtub/shower

    Dec 1, 2020 · Apt C2

    Close
  • Plumbing

    Toilet

    Dec 1, 2020 · Apt C2

    Close
  • Plumbing

    Basin/sink

    Dec 1, 2020 · Apt C2

    Close
  • Unsanitary condition

    Pests

    Dec 1, 2020 · Apt C2

    Close
  • Paint/plaster

    Wall

    Sep 12, 2019 · Apt A1

    Close
  • Unsanitary condition

    Sewage

    Sep 12, 2019 · Apt A1

    Close
  • Unsanitary condition

    Pests

    Sep 12, 2019 · Apt A1

    Close
  • Unsanitary condition

    Pests

    Sep 12, 2019 · Apt A1

    Close
  • Plumbing

    Steam pipe/riser

    Sep 12, 2019 · Apt A1

    Close
  • Water leak

    Heavy flow

    Mar 10, 2019 · Apt D5

    Close
  • Water leak

    Slow leak

    Feb 18, 2019 · Apt D5

    Close
  • Unsanitary condition

    Pests

    Jan 17, 2019 · Apt B2

    Close
  • Flooring/stairs

    Floor

    Jan 17, 2019 · Apt B2

    Close
  • Water leak

    Damp spot

    Jan 17, 2019 · Apt B2

    Close
  • General

    Cabinet

    Jan 17, 2019 · Apt B2

    Close
  • Plumbing

    Basin/sink

    Jan 17, 2019 · Apt B2

    Close
  • Unsanitary condition

    Mold

    Jan 17, 2019 · Apt B2

    Close
  • Heat/hot water

    Apartment only

    Dec 27, 2018 · Apt D5

    Close
  • Unsanitary condition

    Pests

    Dec 19, 2018 · Apt 2B

    Close
  • Appliance

    Refrigerator

    Dec 19, 2018 · Apt 2B

    Close
  • Unsanitary condition

    Pests

    Dec 19, 2018 · Apt 2B

    Close
  • Unsanitary condition

    Mold

    Dec 19, 2018 · Apt 2B

    Close
  • Plumbing

    Basin/sink

    Dec 19, 2018 · Apt 2B

    Close
  • Unsanitary condition

    Pests

    Oct 8, 2018 · Apt C2

    Close
  • Unsanitary condition

    Pests

    Oct 8, 2018 · Apt C2

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
1917
Floors
6
Residential units
29
Building area
21,120 ft²
Lot area
5,000 ft²
Zoning
R7-1
Community board
204
Council district
16
Block / lot
2427 / 35
Assessed value
$832,950
Landmark / historic district
No

HPD registration #213209, last renewed Jul 9, 2026.

Questions about 1255 Webster Avenue

Who owns 1255 Webster Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 1251-55 Webster Ave. LLC.

Does 1255 Webster Avenue have violations?

Yes. NYC HPD has recorded 452 housing violations at this property.

Is 1255 Webster Avenue rent stabilized?

NYC Department of Finance tax bills listed 28 rent-stabilized units here in 2024 (about 97% of its 29 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 1255 Webster Avenue built?

City records list 1917 as the year it was built.

How many apartments are in 1255 Webster Avenue?

It has 29 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.