roofy

2550 3 Avenue

Bronx, NY 10454BBL 2-02314-0001Map

Owner of record: East One Thirty Eighth Housing Developme Nt Fund

2550 3 Avenue is an elevator apartment building built in 2016 in Bronx, 10454. It has 119 residential units across 11 floors. The owner of record is East One Thirty Eighth Housing Developme Nt Fund. HPD has recorded 6 housing violations here, most recently on June 11, 2025. 1 of the 6 most recent violations are still open. City tax records listed 119 rent-stabilized apartments here in 2024.

HPD violations
6
DOB violations
44
ECB violations
42
HPD complaints
33

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 11, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
119
About 100% of the building's 119 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 6

  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling and walls in the bathroom located at apt 2l, 2nd story, 1st apartment from west at north

    Jun 11, 2025 · Apt 2L

    Closed — Violation closed
  • A

    Properly repair or replace the broken or defective mortise lock at door in the entrance located at apt 11n, 11th story, 1st apartment from west at north

    Jun 12, 2024 · Apt 11N

    Closed — Violation dismissed
  • C

    Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 2, wg to replace = 2, wg to repair = 0 in the entire apartment located at apt 11n, 11th story, 1st apartment from west at north

    Jun 12, 2024 · Apt 11N

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective window locking device in the 2nd room from east at north located at apt 11n, 11th story, 1st apartment from west at north

    Jun 12, 2024 · Apt 11N

    Closed — Violation dismissed
  • B

    Trace and repair the source and abate the visible mold condition... mold at ceiling apprx 10 sq ft in the bathroom located at apt 7f, 7th story, 2nd apartment from west at north

    Nov 11, 2021 · Apt 7F

    Open — First no access to re- inspect violation
  • A

    Paint with light colored paint to the satisfaction of this department ceiling in the bathroom located at apt 7f, 7th story, 2nd apartment from west at north

    Nov 11, 2021 · Apt 7F

    Closed — Violation dismissed

DOB building violations · 44

  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9a technical report by 02/21/2022

    Feb 22, 2022

    Dob violation - active
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 27, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 6, 2015

    Dob violation - resolved
Show 34 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 6, 2015

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 9, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 9, 2014

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2011 inspection report

    Mar 1, 2013

    Dob violation - dismissed
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 7a technical report by 02/21/2012

    Jan 31, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 3, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 3, 2013

    Dob violation - resolved
  • Facade facade optional

    Unsafe local law report filed

    Mar 21, 2012

    Dob violation - dismissed
  • Facade facade optional

    Unsafe local law report file late

    Mar 21, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 17, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 17, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 16, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 16, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 20, 2010

    Dob violation - resolved
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 6, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 6, 2008

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 2, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 21, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 1, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 18, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 18, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 14, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 14, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 22, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 22, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    2p5071

    May 8, 2000

    Dob violation - resolved
  • Elevator elevatorrequired

    2p5072

    May 8, 2000

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 10, 2000

    Dob violation - dismissed

ECB violations · 42

  • Class - 2

    Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#917645.rem:submit acceptable required t

    Dec 9, 2022

    Resolve
  • Class - 1

    Bc3301.1.3 manufacturer specifications. note: at the time of my inspection of an 11 story building at bulkhead level, construction work in progrss. i observed man lift operation in progress from grade level to

    Feb 6, 2018 · Penalty $1,600

    Resolve
  • Class - 2

    Bc3301.7 documents to be kept on site. note: at the time of my inspection of an 11 story building at bulkhead level, construction work in progress. i observed multiple trades on site accessing perimeter to perf

    Feb 6, 2018 · Penalty $400

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping. note: at the time of my inspection of an 11 story building at bulkhead level, construction work in progress. i observed multiple areas on construction site floors, wal

    Feb 6, 2018 · Penalty $400

    Resolve
  • Class - 1

    Failure to maintain:guardrails.note:8 story building erected to the 4fl-at 3rd flr level at expo #1 & 3 there is no guardrail in place causing a hazard.(fall)rem:institute safety measures.

    Jun 29, 2017 · Penalty $1,200

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by construction.@time of inspection hmo#8084 todd hoyee was operating cd#4345 cn#420/17when he lifted a plank from a truck when the load shifted out & came i

    Jun 29, 2017 · Penalty $10,030

    Resolve
  • Class - 1

    Bc3309.1/failure to protection and adequately protect adjoining properties during construction operations.note:8 story building erected to the 4th fl level-block/plank jobsite.at expo #4 the adjacent property

    Jun 29, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and or approved amendments.noted:8 story building erected to the 4th flr level.at expo#1 in the street on e 138 st the site has trucks/equipment barracad

    Jun 29, 2017 · Penalty $1,000

    Resolve
  • Class - 2

    Failure to safeguard all persons and property attached by constructionoperation.note:8 story building erected to the 4th flr level,at expo#3there is no over head protection in place causing a hazard on site.the

    Jun 29, 2017 · Penalty $5,000

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and or approved amendments:sidewalk shed.note:8 story building erected to the 4th flr level the sidewalk shed at expo#1 is not created as approved plan o

    Jun 29, 2017 · Penalty $250

    Resolve
Show 32 more ↓
  • Class - 2

    Failure to maintain adequate housekeeping.note at time of inspection of 11 story new building at bulkhead level.i observed on several floorsconstruction materials and construction debris scattered at various lo

    May 10, 2017

    Resolve
  • Class - 2

    Sec: bc 3316.3. failure to immediately notify dob of an accident involving hoisting machinery. @ time of insp it was determined that a knuckle boom crane struck a nearby worker. when assessing the incident it w

    May 1, 2017 · Penalty $400

    Resolve
  • Class - 1

    Inadequate safety measures, operation of crane/dorrick hoisting equipment in an unsafe manner. @ time of insp it was discovered that a knuckle boom crane (the plumbing exchange inc) struck a nearby worker. oper

    May 1, 2017

    Resolve
  • Class - 2

    Sec. 3301.1.2 failure to comply"new york fire code". no required fire dept going(box)has been provided on site as required,missing going box has been metal in fire safety manager log book. nb place has reached

    Jan 9, 2017 · Penalty $830

    Resolve
  • Class - 1

    Failure to procvide sidewalk shed where required. concrete form work has been erected to 2nd sty for the entire length of site along 3rd ave& approx 20' on e 139 st(n/w/c). this(form work)is only set back appro

    Jan 9, 2017 · Penalty $4,830

    Resolve
  • Class - 2

    Work does not conform to approved construction documents or approved plans 20' swing gate located at s/w/c of site is contrary to site safety plans. ssp show only a solid 8' fence to be erected at this located

    Jan 9, 2017 · Penalty $530

    Resolve
  • Class - 2

    Sec. 3307.5 no flagman provided as required by this section of code. aobserved at time of inspection a"port o john"(trash)at nite(parked)acroos sidewalk on e 139 st. the gate to the site was open w/not flagman

    Jan 9, 2017 · Penalty $830

    Resolve
  • Class - 1

    Bc3313.1 compressed gas-not stored-properly. at time of inspection observed an active construction site at foundation stage.during inspect tion noted that the contractor was done for the day and compressed gas

    Nov 2, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments.noted: active 11 story bldg in foundation phase at exp#3 adjacent property has apprx 6 full sized windows and there is no pro

    Oct 27, 2016 · Penalty $1,030

    Resolve
  • Class - 1

    Failure to maintain: no guardrails. noted: at time of inspection at side within foundation phase. ther eis a trench dugout apprx 40' long and depth ranging from 6'to voer 13' is areas with no guardrails in

    Oct 27, 2016 · Penalty $1,200

    Resolve
  • Class - 1

    Bc3304.4.1 support of excavation: no adequate.noted: active site within foundation phase. ther eis a trench apprx 40' long and depth ranges form 6'12' at points. it is not shored, supported or sloped adequately

    Oct 27, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Bc3301.1.1 responsibility for safet: no rebar caps.noted: at time of inspection of 11 stor bldg at foundation phase.there are various areason site w/rebar protruding up from the ground that has no caps causin

    Oct 27, 2016 · Penalty $1,600

    Resolve
  • Class - 2

    Bc3307.7.5 design of fences not provided. noted: active site, foundation work in progress, const rence erected at exp1,2,3,4.there is not site speciic design drawing for fence. rmdy: provide pe design drawing

    Oct 27, 2016 · Penalty $500

    Resolve
  • Class - 1

    Bc3310.8 site safety managers/coordinators ( ). noted: active site of 11story bldg at foundation phase i observed followign class 1 safety plan; 2-excavation no shored/sloped 3 missign rebar caps. reynaldo

    Oct 27, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Failure to safeguard all persons an property affected by construction operations.constractor stated: doing drilling operation at construction site a worker was hurt by a 12"caisson pile, caisson rolled on the w

    Sep 23, 2016 · Penalty $10,000

    Resolve
  • Class - 2

    Removal of sidewalk sheds &/or other type of safety measures w/out de pt's approval.rem:obtain approval from dob for sidewalk sited,fence etc.removal as per 1rcny 103-04(b)(5)(iii)

    Feb 26, 2015 · Penalty $400

    Resolve
  • Class - 2

    Sec. 28-302.5 local law report (cycle 7) filed as "unsafe" by architect/enginer; no amended report was filed. "unsafe conditions" require safety provisions for the public as per 27-9(d) & 1rcny 32-03(b)(5)(i)

    May 8, 2012

    Resolve
  • Class - 2

    Failure to provide safety measures or sidewalk shed where required according to the cycle #6 technical (tr-6) report filed as unsafe, unsafeconditions exists as per 27-129 & 1 rcny 32-03 of the local law 11/98

    Oct 27, 2009 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to file an amended sixth round report acceptable to this department indicating correction of unsafe conditions described in initial local law 11/98 report. remedy: file an amended report following remed

    Dec 19, 2008 · Penalty $800

    Resolve
  • Class - 2

    100x10 97x10 / 100x10 intercom not working repair provide 2way communication 97x10 device inoperative repair & return to service

    Nov 25, 2008 · Penalty $2,500

    Resolve
  • Non-hazardous

    83 x 10/83-repair,restore & provide service

    Jan 18, 2007 · Penalty $2,500

    Resolve
  • Non-hazardous

    86u05,02l10,01l10. 86- perform & file 2 yr test. 02- alarm bell not working. 01- emergency stop switch bell not working.

    Oct 13, 2006 · Penalty $2,500

    Resolve
  • Non-hazardous

    83x10 83- restore repair and provide service so a full inspection could be done by this department.

    Jan 6, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    83-x-10 restore elevator be to secure to by inspection by dob

    Dec 16, 2005 · Penalty $180

    Resolve
  • Non-hazardous

    83x11 restore to service so that a full inspection can be made by thisdept.

    Oct 14, 2005 · Penalty $350

    Resolve
  • Non-hazardous

    41r09/ 85bb05/ 84xxxx/ 04m07/ 41=jump fuses. 84=running without sign off for ebn 911/99 remedy: have device tested for ebn 911/99 * (4) keys.

    Sep 14, 2005 · Penalty $3,000

    Resolve
  • Non-hazardous

    85bb05/39o02/55y13/52b14/66o02

    Feb 11, 2005 · Penalty $2,500

    Resolve
  • Non-hazardous

    85bb05/39o02/55y13/52b14/66o2

    Feb 11, 2005 · Penalty $2,500

    Resolve
  • Hazardous

    9h12,15m7,16h12,22m12,31q3,44q3,37u16,50u16,54u16. -15 floor #s in hoistway, -16 2,3,5,6 & 7 fls., -31 car top, -37,50,54 city i.d. tags must be reversed call 212-312-8730 when repairs are made

    Apr 23, 1999 · Penalty $2,500

    Resolve
  • Non-hazardous

    11i11,15m7,16h12,18q3,22y2,25q3,31q3,57g12,37u16,50u16,54u16. -11 un- der car, -15 floor # in hoistway, -16 1,2,3,4,5 & b fls., -31 car top,-37,50,54 city i.d. tag # must be reversed

    Apr 23, 1999

    Resolve
  • Non-hazardous

    37t7,53b10,54t7,75u5. 37--city i.d. number missing. 54--company logo. 75-perform file five test properlly tag device and flie elev. 3 form

    Jul 14, 1998 · Penalty $2,500

    Resolve
  • Non-hazardous

    14m,51i,73#,73 perform 5 year test, properly tag device and file elev 3 forms.

    Mar 10, 1992 · Penalty $1,000

    Resolve

Complaints

  • Heat/hot water

    Entire building

    May 24, 2026 · Apt BLDG

    Close
  • Plumbing

    Toilet

    Apr 4, 2026 · Apt 7J

    Close
  • Heat/hot water

    Entire building

    Mar 17, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Nov 4, 2025 · Apt 2G

    Close
  • Door/window

    Door

    Jun 19, 2025 · Apt 5D

    Close
  • Safety

    Smoke detector

    May 5, 2025 · Apt 2L

    Close
  • Water leak

    Heavy flow

    May 5, 2025 · Apt 2L

    Close
  • Safety

    Carbon monoxide detector

    May 5, 2025 · Apt 2L

    Close
  • Plumbing

    Water supply

    Apr 19, 2025 · Apt 3N

    Close
  • Elevator

    Maintenance

    Feb 19, 2025 · Apt 11N

    Close
Show 23 more ↓
  • General

    Signage missing

    Feb 19, 2025 · Apt 11N

    Close
  • Appliance

    Refrigerator

    Nov 25, 2024 · Apt 7G

    Close
  • Door/window

    Door

    Apr 4, 2024 · Apt 11N

    Close
  • Appliance

    Electric/gas range

    Mar 11, 2024 · Apt 2L

    Close
  • Plumbing

    Toilet

    Mar 11, 2024 · Apt 2L

    Close
  • Plumbing

    Basin/sink

    Sep 11, 2023 · Apt 7G

    Close
  • Plumbing

    Basin/sink

    Sep 8, 2023 · Apt 7G

    Close
  • General

    Mailbox

    Jul 11, 2023 · Apt 11N

    Close
  • General

    Bell/buzzer/intercom

    Jan 15, 2023 · Apt 11N

    Close
  • Heat/hot water

    Apartment only

    Dec 26, 2022 · Apt 7M

    Close
  • General

    Cooking gas

    Dec 26, 2022 · Apt 7M

    Close
  • Heat/hot water

    Entire building

    Dec 25, 2021 · Apt 110

    Close
  • Heat/hot water

    Entire building

    Dec 25, 2021 · Apt 2L

    Close
  • General

    Cooking gas

    Dec 25, 2021 · Apt 2L

    Close
  • Heat/hot water

    Apartment only

    Dec 25, 2021 · Apt 3E

    Close
  • General

    Cooking gas

    Dec 25, 2021 · Apt 11N

    Close
  • Heat/hot water

    Entire building

    Dec 25, 2021 · Apt 11N

    Close
  • Unsanitary condition

    Mold

    Oct 31, 2021 · Apt 7F

    Close
  • Water leak

    Slow leak

    Nov 23, 2020 · Apt APARME

    Close
  • Water leak

    Heavy flow

    Oct 9, 2020 · Apt 11N

    Close
  • Heat/hot water

    Entire building

    Nov 30, 2019 · Apt 2

    Close
  • Heat/hot water

    Apartment only

    Oct 30, 2019 · Apt 2L

    Close
  • Heat/hot water

    Entire building

    Oct 27, 2019 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2016
Floors
11
Residential units
119
Building area
110,682 ft²
Lot area
22,794 ft²
Zoning
R7-2
Community board
201
Council district
8
Block / lot
2314 / 1
Assessed value
$5,481,900
Landmark / historic district
No

HPD registration #228076, last renewed Jul 16, 2025.

Questions about 2550 3 Avenue

Who owns 2550 3 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is East One Thirty Eighth Housing Developme Nt Fund.

Does 2550 3 Avenue have violations?

Yes. NYC HPD has recorded 6 housing violations at this property.

Is 2550 3 Avenue rent stabilized?

NYC Department of Finance tax bills listed 119 rent-stabilized units here in 2024 (about 100% of its 119 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 2550 3 Avenue built?

City records list 2016 as the year it was built.

How many apartments are in 2550 3 Avenue?

It has 119 residential units and 122 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.