11 East 31 Street
Manhattan, NY 10016BBL 1-00861-0010Map
Owner of record: Ayya Hotel, LLC
11 East 31 Street is a hotel built in 2014 in Manhattan, 10016. The owner of record is Ayya Hotel, LLC. HPD has recorded 1 housing violation here, most recently on February 2, 2015.
- HPD violations
- 1
- DOB violations
- 27
- ECB violations
- 41
- HPD complaints
- 5
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 1
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Feb 2, 2015
Closed — Violation dismissed
DOB building violations · 27
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 5, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 5, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 5, 2021
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 4, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 4, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 21, 2017
Dob violation - resolved
Show 17 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Aug 21, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 21, 2017
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 10, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 21, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 21, 2014
Dob violation - resolved - Elevator elevatorrequired
Illegal removal
Jun 2, 2008
Vw*-violation - work w/o permit dismissed - Construction other optional
C-construction other optional
Apr 2, 2008
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 20, 2007
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 2, 2007
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Oct 1, 2005
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 6, 2004
Dob violation - resolved - Elevator elevatorrequired
1p5575
Oct 24, 2002
Dob violation - resolved - Construction other optional
C-construction other optional
Oct 28, 1999
Dob violation - dismissed
ECB violations · 41
- Class - 2
Fail to maintain building in code compliant manner re: installation/maintenance of plumbing material/equipment per pc 102.3, 27-902. time ofinspection i observed defective valve for dry standpipe system to pres
Mar 3, 2016
Resolve - Class - 1
Failure to safeguard all persons and property affected by construction@ the 29 floor observed man working on leading edge of bldg via man lift installing window components.the lift was extended out past bldg li
Aug 12, 2015 · Penalty $2,400
Resolve - Class - 1
Failure to maintain:no handrails.note:30 story bldg under construction observed in staircase a+b from floors 21-14 there were no handrails installed causing a hazard to workers/others using stairs.rem:provide h
Aug 12, 2015 · Penalty $1,000
Resolve - Class - 2
Sidewalk shed does not meet code specifications.note:30 story bldg under construction.@ exp.#1 the sidewalk shed wiring is not per code.observed a 2 seperate location yellow exposed wiring carried from lights u
Aug 12, 2015 · Penalty $2,400
Resolve - Class - 2
Failure to comply w/the comm's order to file c of c w/the dob's for notice of vio #35153697y issued on 4/2/15 pursuant to 28-204.4 & 1rcny1 02-01. remedy: file a c of c.
May 23, 2015 · Penalty $400
Resolve - Class - 2
Failure to comply w/commissioner's order to file a certificate of correction w/dob for nov #35153698x issued on 3/27/15 pursuant to 28-204.4and 1rcny 102-01. failure to provide unobstructed exit passageway at
May 15, 2015 · Penalty $400
Resolve - Class - 1
3308.1.3 horizontal safety not provided during new construction concrete building.@ time of inpsection active construction site building complete to 23 stories.observed installation system with remain form work
May 12, 2015 · Penalty $1,600
Resolve - Class - 2
Failure to maintain alternate housekeeping per section requirement at time of inspection active construction site concrete building observed accumulation of construction debris consist of plywood,foam, 2"x 4" p
May 12, 2015
Resolve - Class - 1
Failure to institute maintain safety equipment measures or temp.construction toe boards.note active construction site.building complete to 23 stories observed missing toe board along electrical shaft way 18th f
May 12, 2015 · Penalty $1,000
Resolve - Class - 1
3301.2. holes/opening not covered @ time of insp.active construction site.observed hole opening 2"to 18"on various floors around mechanical duet work and plumbing risers also plywood not secured over openings w
May 12, 2015 · Penalty $1,600
Resolve
Show 31 more ↓
- Class - 1
Mc801.1.1.1,failure to extend adjoining chimney of bldg @ 15 west 31 street as per code.note:existing brcik chimney not extended or corrected after overhanging structure of new bldg was erected w/ permit #12132
Apr 2, 2015 · Penalty $1,630
Resolve - Class - 1
Failure to provide unobstructed exit passageway.defect noted:@ rear of15 e 31 street.(1)blocking 1st fl fire escape @ rear w/ plywood reading"no exit"signage(2)temp egress w/ jo #121952583 shows exit signage po
Mar 27, 2015 · Penalty $1,000
Resolve - Class - 2
Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed active jobsite. at the 5th & 6th fl observed outrigger platforms at rear exposure used during
Feb 25, 2015
Resolve - Class - 1
Work does not conform to approved construction documents-site safety plan.noted: fire escape of adjacent proeprty at exp4 (15 east 31 st)isnot protected within 20' to site; hoist being erected at exposure3
Feb 11, 2015 · Penalty $1,000
Resolve - Class - 1
Bc3314.4.3 no record of daily inspection of supported scaffold performed by competent person at site noted: sidewalk shed erected at exposure 1 for pedestrian protection. last maintenance log inspection was don
Feb 11, 2015 · Penalty $1,600
Resolve - Class - 2
28-110.1 osha 10 noted: site safety manager vadim leykin #1863 does not have osha card on him (not even a copy). rmdy: comply with code.
Feb 11, 2015
Resolve - Class - 1
Sec. 3303.6 escape hatches: not provided. at time of inspection observed active jobsite. observed at the 2nd fl(mezz)approx 4 heaters used to heat 3rd fl where concrete(pouring)operations are talking place. no
Feb 3, 2015 · Penalty $1,600
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations. at time of inspection observed active jobsite. worker was positioned on a ladder against a wall chopping back some wire mesh.
Feb 3, 2015 · Penalty $2,400
Resolve - Class - 1
Sec. 3301.1.2 failure to comply w/nyc fire code - general no fire watch,fire guard. certificate of fitness. at time of inspection observed active jobsite worker using corridor causing sparks,smoke. i did not
Feb 3, 2015 · Penalty $1,600
Resolve - Class - 1
Work does not conform to approved construction document - soe plan observed 3 workers in a pit;worker cutting caissons - site are not protected as per soe plan (soil not at proper angle). remedy: stop all work
Nov 24, 2014 · Penalty $1,000
Resolve - Class - 1
3317.1 general.all (h ),transporting,storage installation connection (v )flammable and combustible mixtures.note:men working on (b ) ops.fdny fire code 140815-hot work ops-no fireguard was present w/in ops area
Nov 20, 2014 · Penalty $1,600
Resolve - Class - 1
3310.6 designated concrete site safety manager.note:active concrete job in prog,subcellar formed.men ( )excavator moving dirt from site.dob rec show frank vega as csm since nov 1.logs show mark vaktileg was csm
Nov 20, 2014 · Penalty $400
Resolve - Class - 2
3310.8.3mis.vio. no log books for concrete pump @ time of inspec.no in progress foundation work concrete pump in use no log book for pump hose on site.remedy:stop all concrete pumping & provide logs.
Nov 5, 2014
Resolve - Class - 1
Contrary to plans, noteice at time of inspec.nb in progress.site safety plan shows fully enclosed barricaded walkway or street for pedestrians walkway also shows ramp on site to have full timber barricades on b
Nov 5, 2014 · Penalty $1,000
Resolve - Class - 1
3303.15.1mis.vio.collection & containment noticed at tie of inspec. nb in rogress pouring foundations noticed concrete w/o boxes nor pre manufactured water tight containers as per code.remedy:comply w/code.
Nov 5, 2014 · Penalty $400
Resolve - Class - 1
3303.15misc.vio.concrete washout water shall not be allowed to enter any sewer,catch basin,vault, drain or body of water or leaks into ground.noteiced concrete pump truck wahout wakes on street & runing into dr
Nov 5, 2014 · Penalty $400
Resolve - Class - 1
28-110.1 ssm shall provide a statement that all workers employed on s ite will secure a site specific orientation program.noticed @ time of insp.nb in progress.ssm on site & on pw2 vadim leykin ss# 1863 had no
Sep 29, 2014 · Penalty $400
Resolve - Class - 1
28-110.1 osha 10.noticed @ time of insp.nb in progress foundation & excavcation work on going notice 3 workers working site no osha 10 certificate on site.rem:provide osha 10 as per code.
Sep 29, 2014 · Penalty $1,600
Resolve - Class - 2
Sec. 3301.1.2 failure to comply w/nyc fire code. no permit for oxygen & acelylene stored at site. at time of inspection observed several tanks of combustile gas stored & no valid permit as required by code.
Aug 19, 2014
Resolve - Class - 2
Electrical work w/o a permit. note at time of inspection new bldg under construction permit #12132591 excavation phase observed at exp 4 wall electrical conduits power being supply from adjacent bldg 15 e 31 st
Aug 19, 2014
Resolve - Class - 1
3307.4.3 failure to have yoduck barricades fill w/water or sand as required by manufactue.@ time of insp const ops work in progress i observed approx 60ft of yoduck barricades in roadway closing one lane for pe
Jun 10, 2014 · Penalty $8,000
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. noted: construction site fence erected under permit #121325921-01-eq-fn issued on 8/9/13 expires on 8/9/14 does not comply w/local law 47 of
Oct 1, 2013 · Penalty $400
Resolve - Class - 1
Failure to provide site safety manager. at time of inspection,observedjob site in operations - workers on site - excavation in proper - no site safety manager at site. remedy: stop entire site - provide site
May 1, 2013 · Penalty $2,400
Resolve - Class - 2
Sec. 3310.3 failure to provide site safety plan & program as require -at time of inspection,observed job site in operations - no site safetyplan provided - observed workers on site. remedy: stop entire site -
May 1, 2013
Resolve - Class - 2
Failure to safeguard all persons and property affected by constructionfoundations operations. at the time of my inspection. i observed sidewalk close in front of site, a temporarily walkway was erected 3'w in
Apr 24, 2013 · Penalty $1,200
Resolve - Non-hazardous
Work w/an expired permit. note: upon inspection of the above demolition site dob records are showing demolition permit # 104820384-01-dm hasexpired on 1/1/08. remedy: renew permit as per bldg code.
Jan 11, 2008 · Penalty $200
Resolve - Non-hazardous
Work w/o a permit (expired permit). note: upon inspection of the abovedemolition site a sidewalk shed is erected & dob records are showing shed permit #104820384-02-eq-sh as expired on 1/1/08. remedy: renew
Jan 11, 2008 · Penalty $200
Resolve - Non-hazardous
Work w/o a permit (expired permit) note upon inspection of the above demolition site dob records are showing fence permit # 104820384-01-fn has expired on 12/31/07. remedy: renew permits as per bldg code.
Jan 11, 2008
Resolve - Non-hazardous
83x10 83-x-10 repair so that a proper inspection can be made by this department (dob)212 566 5542
Sep 20, 2004
Resolve - Non-hazardous
48bb13
Mar 7, 2003
Resolve - Non-hazardous
22d,25m,48b,49b,50y,53y,50o, 25-cover door operator 52-replace oil soaked brakes
Sep 23, 1997 · Penalty $100
Resolve
Complaints
- Heat/hot water
Entire building
Nov 18, 2014 · Apt BLDG
Close - Heat/hot water
Entire building
Nov 13, 2014 · Apt BLDG
Close - Nonconst
Rubbish
Aug 18, 2004 · Apt BLDG
Close - Nonconst
Vermin
Aug 18, 2004 · Apt BLDG
Close - Nonconst
Vermin
Aug 18, 2004 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H3)
- Year built
- 2014
- Floors
- 31
- Residential units
- —
- Building area
- 78,843 ft²
- Lot area
- 4,319 ft²
- Zoning
- C5-2
- Community board
- 105
- Council district
- 4
- Block / lot
- 861 / 10
- Assessed value
- $20,905,200
- Landmark / historic district
- No
HPD registration #142675, last renewed Jul 28, 2015.
Questions about 11 East 31 Street
Who owns 11 East 31 Street?
The owner of record in NYC Department of City Planning PLUTO data is Ayya Hotel, LLC.
Does 11 East 31 Street have violations?
Yes. NYC HPD has recorded 1 housing violations at this property.
Is 11 East 31 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 11 East 31 Street built?
City records list 2014 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.