roofy

11 East 31 Street

Manhattan, NY 10016BBL 1-00861-0010Map

Owner of record: Ayya Hotel, LLC

11 East 31 Street is a hotel built in 2014 in Manhattan, 10016. The owner of record is Ayya Hotel, LLC. HPD has recorded 1 housing violation here, most recently on February 2, 2015.

HPD violations
1
DOB violations
27
ECB violations
41
HPD complaints
5

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Feb 2, 2015

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 2, 2015

    Closed — Violation dismissed

DOB building violations · 27

  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 5, 2021

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 5, 2021

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 5, 2021

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Jan 17, 2020

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Jan 17, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 4, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 4, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2017

    Dob violation - resolved
Show 17 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2017

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2015 inspection/test

    Dec 1, 2016

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2015 inspection/test

    Dec 1, 2016

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2015 inspection/test

    Dec 1, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 10, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    Illegal removal

    Jun 2, 2008

    Vw*-violation - work w/o permit dismissed
  • Construction other optional

    C-construction other optional

    Apr 2, 2008

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 21, 2008

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 20, 2007

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 2, 2007

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Oct 1, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 6, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    1p5575

    Oct 24, 2002

    Dob violation - resolved
  • Construction other optional

    C-construction other optional

    Oct 28, 1999

    Dob violation - dismissed

ECB violations · 41

  • Class - 2

    Fail to maintain building in code compliant manner re: installation/maintenance of plumbing material/equipment per pc 102.3, 27-902. time ofinspection i observed defective valve for dry standpipe system to pres

    Mar 3, 2016

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by construction@ the 29 floor observed man working on leading edge of bldg via man lift installing window components.the lift was extended out past bldg li

    Aug 12, 2015 · Penalty $2,400

    Resolve
  • Class - 1

    Failure to maintain:no handrails.note:30 story bldg under construction observed in staircase a+b from floors 21-14 there were no handrails installed causing a hazard to workers/others using stairs.rem:provide h

    Aug 12, 2015 · Penalty $1,000

    Resolve
  • Class - 2

    Sidewalk shed does not meet code specifications.note:30 story bldg under construction.@ exp.#1 the sidewalk shed wiring is not per code.observed a 2 seperate location yellow exposed wiring carried from lights u

    Aug 12, 2015 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to comply w/the comm's order to file c of c w/the dob's for notice of vio #35153697y issued on 4/2/15 pursuant to 28-204.4 & 1rcny1 02-01. remedy: file a c of c.

    May 23, 2015 · Penalty $400

    Resolve
  • Class - 2

    Failure to comply w/commissioner's order to file a certificate of correction w/dob for nov #35153698x issued on 3/27/15 pursuant to 28-204.4and 1rcny 102-01. failure to provide unobstructed exit passageway at

    May 15, 2015 · Penalty $400

    Resolve
  • Class - 1

    3308.1.3 horizontal safety not provided during new construction concrete building.@ time of inpsection active construction site building complete to 23 stories.observed installation system with remain form work

    May 12, 2015 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to maintain alternate housekeeping per section requirement at time of inspection active construction site concrete building observed accumulation of construction debris consist of plywood,foam, 2"x 4" p

    May 12, 2015

    Resolve
  • Class - 1

    Failure to institute maintain safety equipment measures or temp.construction toe boards.note active construction site.building complete to 23 stories observed missing toe board along electrical shaft way 18th f

    May 12, 2015 · Penalty $1,000

    Resolve
  • Class - 1

    3301.2. holes/opening not covered @ time of insp.active construction site.observed hole opening 2"to 18"on various floors around mechanical duet work and plumbing risers also plywood not secured over openings w

    May 12, 2015 · Penalty $1,600

    Resolve
Show 31 more ↓
  • Class - 1

    Mc801.1.1.1,failure to extend adjoining chimney of bldg @ 15 west 31 street as per code.note:existing brcik chimney not extended or corrected after overhanging structure of new bldg was erected w/ permit #12132

    Apr 2, 2015 · Penalty $1,630

    Resolve
  • Class - 1

    Failure to provide unobstructed exit passageway.defect noted:@ rear of15 e 31 street.(1)blocking 1st fl fire escape @ rear w/ plywood reading"no exit"signage(2)temp egress w/ jo #121952583 shows exit signage po

    Mar 27, 2015 · Penalty $1,000

    Resolve
  • Class - 2

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed active jobsite. at the 5th & 6th fl observed outrigger platforms at rear exposure used during

    Feb 25, 2015

    Resolve
  • Class - 1

    Work does not conform to approved construction documents-site safety plan.noted: fire escape of adjacent proeprty at exp4 (15 east 31 st)isnot protected within 20' to site; hoist being erected at exposure3

    Feb 11, 2015 · Penalty $1,000

    Resolve
  • Class - 1

    Bc3314.4.3 no record of daily inspection of supported scaffold performed by competent person at site noted: sidewalk shed erected at exposure 1 for pedestrian protection. last maintenance log inspection was don

    Feb 11, 2015 · Penalty $1,600

    Resolve
  • Class - 2

    28-110.1 osha 10 noted: site safety manager vadim leykin #1863 does not have osha card on him (not even a copy). rmdy: comply with code.

    Feb 11, 2015

    Resolve
  • Class - 1

    Sec. 3303.6 escape hatches: not provided. at time of inspection observed active jobsite. observed at the 2nd fl(mezz)approx 4 heaters used to heat 3rd fl where concrete(pouring)operations are talking place. no

    Feb 3, 2015 · Penalty $1,600

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by construction operations. at time of inspection observed active jobsite. worker was positioned on a ladder against a wall chopping back some wire mesh.

    Feb 3, 2015 · Penalty $2,400

    Resolve
  • Class - 1

    Sec. 3301.1.2 failure to comply w/nyc fire code - general no fire watch,fire guard. certificate of fitness. at time of inspection observed active jobsite worker using corridor causing sparks,smoke. i did not

    Feb 3, 2015 · Penalty $1,600

    Resolve
  • Class - 1

    Work does not conform to approved construction document - soe plan observed 3 workers in a pit;worker cutting caissons - site are not protected as per soe plan (soil not at proper angle). remedy: stop all work

    Nov 24, 2014 · Penalty $1,000

    Resolve
  • Class - 1

    3317.1 general.all (h ),transporting,storage installation connection (v )flammable and combustible mixtures.note:men working on (b ) ops.fdny fire code 140815-hot work ops-no fireguard was present w/in ops area

    Nov 20, 2014 · Penalty $1,600

    Resolve
  • Class - 1

    3310.6 designated concrete site safety manager.note:active concrete job in prog,subcellar formed.men ( )excavator moving dirt from site.dob rec show frank vega as csm since nov 1.logs show mark vaktileg was csm

    Nov 20, 2014 · Penalty $400

    Resolve
  • Class - 2

    3310.8.3mis.vio. no log books for concrete pump @ time of inspec.no in progress foundation work concrete pump in use no log book for pump hose on site.remedy:stop all concrete pumping & provide logs.

    Nov 5, 2014

    Resolve
  • Class - 1

    Contrary to plans, noteice at time of inspec.nb in progress.site safety plan shows fully enclosed barricaded walkway or street for pedestrians walkway also shows ramp on site to have full timber barricades on b

    Nov 5, 2014 · Penalty $1,000

    Resolve
  • Class - 1

    3303.15.1mis.vio.collection & containment noticed at tie of inspec. nb in rogress pouring foundations noticed concrete w/o boxes nor pre manufactured water tight containers as per code.remedy:comply w/code.

    Nov 5, 2014 · Penalty $400

    Resolve
  • Class - 1

    3303.15misc.vio.concrete washout water shall not be allowed to enter any sewer,catch basin,vault, drain or body of water or leaks into ground.noteiced concrete pump truck wahout wakes on street & runing into dr

    Nov 5, 2014 · Penalty $400

    Resolve
  • Class - 1

    28-110.1 ssm shall provide a statement that all workers employed on s ite will secure a site specific orientation program.noticed @ time of insp.nb in progress.ssm on site & on pw2 vadim leykin ss# 1863 had no

    Sep 29, 2014 · Penalty $400

    Resolve
  • Class - 1

    28-110.1 osha 10.noticed @ time of insp.nb in progress foundation & excavcation work on going notice 3 workers working site no osha 10 certificate on site.rem:provide osha 10 as per code.

    Sep 29, 2014 · Penalty $1,600

    Resolve
  • Class - 2

    Sec. 3301.1.2 failure to comply w/nyc fire code. no permit for oxygen & acelylene stored at site. at time of inspection observed several tanks of combustile gas stored & no valid permit as required by code.

    Aug 19, 2014

    Resolve
  • Class - 2

    Electrical work w/o a permit. note at time of inspection new bldg under construction permit #12132591 excavation phase observed at exp 4 wall electrical conduits power being supply from adjacent bldg 15 e 31 st

    Aug 19, 2014

    Resolve
  • Class - 1

    3307.4.3 failure to have yoduck barricades fill w/water or sand as required by manufactue.@ time of insp const ops work in progress i observed approx 60ft of yoduck barricades in roadway closing one lane for pe

    Jun 10, 2014 · Penalty $8,000

    Resolve
  • Class - 2

    Job site fence not constructed or maintained pursuant to subsection. noted: construction site fence erected under permit #121325921-01-eq-fn issued on 8/9/13 expires on 8/9/14 does not comply w/local law 47 of

    Oct 1, 2013 · Penalty $400

    Resolve
  • Class - 1

    Failure to provide site safety manager. at time of inspection,observedjob site in operations - workers on site - excavation in proper - no site safety manager at site. remedy: stop entire site - provide site

    May 1, 2013 · Penalty $2,400

    Resolve
  • Class - 2

    Sec. 3310.3 failure to provide site safety plan & program as require -at time of inspection,observed job site in operations - no site safetyplan provided - observed workers on site. remedy: stop entire site -

    May 1, 2013

    Resolve
  • Class - 2

    Failure to safeguard all persons and property affected by constructionfoundations operations. at the time of my inspection. i observed sidewalk close in front of site, a temporarily walkway was erected 3'w in

    Apr 24, 2013 · Penalty $1,200

    Resolve
  • Non-hazardous

    Work w/an expired permit. note: upon inspection of the above demolition site dob records are showing demolition permit # 104820384-01-dm hasexpired on 1/1/08. remedy: renew permit as per bldg code.

    Jan 11, 2008 · Penalty $200

    Resolve
  • Non-hazardous

    Work w/o a permit (expired permit). note: upon inspection of the abovedemolition site a sidewalk shed is erected & dob records are showing shed permit #104820384-02-eq-sh as expired on 1/1/08. remedy: renew

    Jan 11, 2008 · Penalty $200

    Resolve
  • Non-hazardous

    Work w/o a permit (expired permit) note upon inspection of the above demolition site dob records are showing fence permit # 104820384-01-fn has expired on 12/31/07. remedy: renew permits as per bldg code.

    Jan 11, 2008

    Resolve
  • Non-hazardous

    83x10 83-x-10 repair so that a proper inspection can be made by this department (dob)212 566 5542

    Sep 20, 2004

    Resolve
  • Non-hazardous

    48bb13

    Mar 7, 2003

    Resolve
  • Non-hazardous

    22d,25m,48b,49b,50y,53y,50o, 25-cover door operator 52-replace oil soaked brakes

    Sep 23, 1997 · Penalty $100

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Nov 18, 2014 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Nov 13, 2014 · Apt BLDG

    Close
  • Nonconst

    Rubbish

    Aug 18, 2004 · Apt BLDG

    Close
  • Nonconst

    Vermin

    Aug 18, 2004 · Apt BLDG

    Close
  • Nonconst

    Vermin

    Aug 18, 2004 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
2014
Floors
31
Residential units
—
Building area
78,843 ft²
Lot area
4,319 ft²
Zoning
C5-2
Community board
105
Council district
4
Block / lot
861 / 10
Assessed value
$20,905,200
Landmark / historic district
No

HPD registration #142675, last renewed Jul 28, 2015.

Questions about 11 East 31 Street

Who owns 11 East 31 Street?

The owner of record in NYC Department of City Planning PLUTO data is Ayya Hotel, LLC.

Does 11 East 31 Street have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 11 East 31 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 11 East 31 Street built?

City records list 2014 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.