165 Grand Street
Manhattan, NY 10013BBL 1-00235-0013Map
Owner of record: 224 Centre Realty LLC
165 Grand Street is an office building built in 1848 in Manhattan, 10013. It has 3 residential units across 6 floors. The owner of record is 224 Centre Realty LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 117
- ECB violations
- 64
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 117
- Construction other optional
Emergency work order.@cellar&subcellar lvls,crckd walls &walls w/ missng brcks were obsrvd.chimney@roof near the middle of exp4 had mult crcks&was strappd.cellar&subcellar lvls had pre-existng.ownr to rtain nyspe&gc reg w/dob to immed 1.nyspe to submit means&methds for temp shorng/stbliztn of chimney&sidewalk
Apr 20, 2026
Dob violation - active - Construction other optional
Failure to maintain bldg in safe manner.@cellar&subcellar levels,crckd walls&walls w/missng brcks were obsrvd.chimney@roof near the middle of exp4wall had mult crcks&was strapped.cellar&subcellar.1.ownr to rtain nyspe to eval ent strctre&file rpair dwgs w/dob, 2.bldg to be perm rpaird undr prmt strtng by 6/1/2026
Apr 20, 2026
Dob violation - active - Plumbing none
Observed in the basement water leaking from sprinkler system pipe onto the floor
Apr 15, 2026
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - dismissed - Construction other optional
Structure rendered non compliant due to vehicle impacting shed. at time of inspection the vertical post and i-beam was bent knocking shed out of plumb.
May 12, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 18, 2024
Dob violation - active - Immediate emergency anythingoptional
Remedy immediately install 90' linear feet off sidewalk shed at exposure #1 centre street. 80' linear feet of sidewalk shed at expsour e #2 on grand street and 120' linear feet of sidewalk shed at exposure #3 on baxter street. to protect and secure public safety
Jul 3, 2024
Dob violation - active - Landmark none
Landmk-landmark none
Feb 12, 2024
Dob violation - active - Landmark none
Landmk-landmark none
Feb 12, 2024
Dob violation - active
Show 40 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - active - Construction other optional
Emergency work order due to multiple twisted i-beams on sidewalk shed on exp3 east elevation with unsafe condition. shed to be immed repaired. remedy: repair/replace damaged i-beams
Nov 5, 2022
Dob violation - active - Construction other optional
Ftm bldg in code compliant manner. observed cracked chimney, severe spalling throughout facade. damaged cornice cracked window panes, and leaking parapet wall. defective window lintals and sills. spalling brick and stone. all defects are throughout facade. remedy: maintain bldg in a code compliant manner
Nov 4, 2022
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2022
Dob violation - dismissed - Construction other optional
Vehicle impacting sidewalk shed
Nov 18, 2021
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 7, 2021
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 7, 2021
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 15, 2020
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 15, 2020
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 24, 2019
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 30, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 30, 2018
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 4, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 4, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 13, 2015
Dob violation - resolved - High pressure boiler boiler required
Violation issued for failure to file 2013 annual high pressure boiler inspection
Mar 3, 2015
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2013 annual high pressure boiler inspection
Mar 3, 2015
Dob violation - dismissed - Landmark none
Landmk-landmark none
Nov 7, 2014
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 13, 2014
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 13, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 13, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 6, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 6, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 27, 2012
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 4, 2011
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 28, 2011
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 28, 2011
Dob violation - dismissed
ECB violations · 64
- Class - 2
At time of inspection of a 6 stories building i observed sidewalk shed in place on exposures # 1,2,and 3, upon review the department record to verify compliance inspection reveals that there is no permit obtain
May 19, 2026 · Penalty $6,250
Active - Class - 1
Observed throughout the building sprinkler heads are obstructed. on the secound floor there is a lack sprinkler coverage under the mezzanine level in the north side apartment and no spinkler coverage on south e
Apr 15, 2026 · Penalty $12,500
Active - Class - 1
Observed in the basement water leaking from sprinkler system pipe onto the floor. sprinkler head damaged and missing sprinkler protective guards around sprinkler heads which is contrary to code sections bc 101.
Apr 15, 2026 · Penalty $12,500
Active - Class - 1
Observed outside in front of the building the fire department connection is too close to the steps. at the rear side of the building fire department connection missing caps which is contrary to code sections fc
Apr 15, 2026 · Penalty $12,500
Active - Class - 1
Observed in the basement waste lines are not properly capped and fernco couplings are being used on waste lines. the ejector pump discharge line is improperly installed the waste line reduced in size smaller th
Apr 15, 2026 · Penalty $12,500
Active - Class - 1
Issued nov failier to mantain for chimney on roof with major crack and slight delection; sprinkler system off;water leaking in basement; exit doors screwed closed thus creating safety hazard, repair and/replace
Apr 15, 2026 · Penalty $12,500
Active - Class - 2
Temporary construction equipment on site with expired permit. at time of inspection shed installed under permit number m00161861-i1-sh has an expired permit date of 12-31-2020. there are no updated permits on f
May 12, 2025 · Penalty $6,250
Active - Class - 2
At time of inspection of a 6 stories building i observed sidewalk shed in place at exposure # 1 and 2 upon review the department record to verify compliance it shows that the sidewalk shed permit had expired si
Apr 21, 2025 · Penalty $6,250
Active - Class - 2
Failure to maintain building in a code compliant manner.notes:multiplehazardous conditions observed broken glass pane.delaminated/spalling masonry at 2nd stry and 3rd stry.defective at 2nd stry/cornice at roof
Aug 20, 2024 · Penalty $3,125
Active - Class - 1
Failure to maintain building facade in a code-compliant manner. noted at time of inspection, at west elevation exposure #1, north elevation exposure #2 and east elevation exposure #3 observed severly cracked ma
Jul 1, 2024 · Penalty $6,250
Active
Show 40 more ↓
- Class - 2
At the time of my inspection observed sidewalk shed at exp#1,2 and 3. after review department records revealed that sidewalk shed permit expired on 12/31/20.
Feb 22, 2023 · Penalty $1,250
Active - Class - 2
At the time of inspection of a 6 story building partially occupied, no construction activities recorded while responding to a complaint concerning unsafe sidewalk shed i observed shed permit expired on 12/31/2
Feb 16, 2023 · Penalty $1,250
Active - Class - 1
Failure to provide unobstructed exit passageway.observed fire escape egress blocked by sidewalk shed debris.remedy:remove obstruction
Nov 4, 2022 · Penalty $1,250
Active - Class - 2
Temporary construction equipment on-site expired permit.permit#m00161861-l1-sh expired 11/31/20.as of today 11/04/22 no permit in progress or on record.remedy:renew permit.
Nov 4, 2022 · Penalty $1,250
Active - Class - 2
Pedestrian protection does not meet code specifications. observed inadequate shed lighting, damaged mud sills, twisted i-beams, and damaged parapet wall panels. remedy: comply with code specifications
Nov 4, 2022 · Penalty $2,400
Active - Class - 2
Pedestrian protection does not meet code specification at time of inspection on a 6th sty observed sidewalk shed erected at expo#1.missing caps from the bolts at sws can created a hazardous condition for pedest
Nov 23, 2021 · Penalty $10,000
Active - Class - 2
Pedestrian protection does not meet code specification at time of inspection on a 6th sty observed sidewalk shed erected.observed the parapet wall not secure to the sws.a open gap about 3-4 inches at expo#2 cre
Nov 23, 2021 · Penalty $10,000
Active - Class - 2
Temporary construction equipment onsite with expired permit(sws).note:at inspection of 6 story alt bldg,no active work observed sidewalk shed at exposures 1,2&3 in good condition but the permit number m00161861
Nov 19, 2021 · Penalty $6,250
Active - Class - 2
Failure to maintain bldg walls & appurtenance. note: at 6 sty brownstone all exposures at 5th & 6th fl missing bricks & mortar at roof levelshingles missing. remedy: sidewalk shed installed permit#m00161861.
Jul 3, 2019 · Penalty $6,250
Active - Class - 2
Temporary construction equipment on site no permit.note:at the time ofmy inspection i observed a sidewalk shed erected at expo 1,2 and 3.upon review the permit validity on the building information system(bis)it
Apr 30, 2019 · Penalty $6,250
Active - Class - 2
Sidewalk shed parapet panel.note:at the time of my inspection,i observed a sidewalk shed erected at expo 1,2 and 3.i also observed that there were no parapet panel information posted on teh sidewalk shed parape
Apr 30, 2019 · Penalty $6,250
Active - Class - 1
Failure to maintain exterior facade in a code compliant manner. brown stone is failing,missing and in danger of falling on entire facade fronting centre,grand and baxter streets. defects endanger thousands of p
Apr 21, 2019 · Penalty $25,000
Active - Class - 2
Failure to comply w/commissioner's order to file a certificate of correction with the dob for nov#34852921x issued on 11/4/11 pursuant to 28-204.4 & 1rcny 102-01.work w/o a permit on the 3rd flr.rmdy:file a c
Feb 27, 2013 · Penalty $2,000
Active - Class - 1
Failure to comply with the commissioner's order contained in notice ofviolation #34852921x issued on 11-4-11. work w/o a permit at the 3rd floor. rem:comply with the commissioner's order.
Jan 21, 2012 · Penalty $2,400
Resolve - Class - 1
Failure to comply w/the commissioner's order contained in notice of violation #34852921x issued on 11/04/10. remedy: comply w/the comm's order.
Nov 10, 2011 · Penalty $6,000
Resolve - Class - 1
Failure to comply w/the comm's order contained in nov #34852921x issued on 11/04/2011.for work w/o permit at 3rd flr. remedy:comply w/the comm's order.
Sep 1, 2011 · Penalty $6,000
Resolve - Class - 1
Failure to comply w/the comm's order contained in nov #34752168r issued on 05/18/2011 for work w/o permit at 34d flr. remedy:comply w/the comm's order.
Jul 13, 2011 · Penalty $800
Resolve - Class - 1
Failure to comply w/ an order at the comm resp failed to correct the conditions cited in the prior nov#34852921x for work w/o permit at 3rd floor commercial space under renovation rem: comply w/ the comms order
May 18, 2011 · Penalty $800
Resolve - Class - 2
Failure to comply w/ the comm order to file a cert of correction w/ the dob resp failed to comply w/ the comm order to correct the violatingconditions & file a cert of correction pursuant to 28-204.2 for nov#34
Mar 11, 2011
Resolve - Class - 2
Unlawful acts. failure to comply w/an order of the commissioner. respondent failed to correct the conditions cited in the prior nov #34852921x for work w/o a permit @ 3rd fl commercial space under renovation.
Mar 11, 2011 · Penalty $800
Active - Class - 1
Failure to maintain bldg in a code-compliant manner,illegal door hardware. noted: at front entrance/exit door a keyed lock is in place w/thepotential of being locked & not able to be opened from interior.
Jan 31, 2011 · Penalty $1,000
Active - Class - 1
Failure to comply w/ commissioner's order to correct conditions cited in nov # 34852921x for work w/o a permit on landmark bldg. remedy: comply w/ commissioner's order
Jan 20, 2011 · Penalty $800
Resolve - Class - 2
Failure to comply w/commissioner's order to file a certificate of correction for nov #34878545r. remedy: file certificate of correction.
Jan 20, 2011 · Penalty $800
Resolve - Class - 1
Unlawful acts. failure to comply w/an order of the commissioner in that a stop work order has been issued & construction work is being performed w/o having stop work order(resireded). remedy: comply w/commissio
Nov 4, 2010 · Penalty $800
Active - Class - 1
Work w/o permit: at 3rd fl renovating comm space in landmark building no permits posted or plans (approved at site. remedy: stop all work & obtain permits.
Nov 4, 2010 · Penalty $800
Active - Class - 2
Failure to comply w/ an order of the comms respondent failed to file a cert of correction for #34775265z at 2nd fl erected partition & cut wood fl joists rem; file cert of correction
Mar 2, 2010 · Penalty $4,000
Active - Class - 2
Failure to comply with the commissioner's order to fire a certificate of correction w/dept of buildings. for the viol #34775256-2. remedy: comply w/code. fire certificate of correction.
Sep 8, 2009 · Penalty $4,000
Active - Class - 1
Failure to comply with an order of the commissioner. respondent has failed to comply with the conditions in #34775265-z. 2nd flr n/w unit partitions erected wood flr joints were cut down in size. sprinkler
Sep 8, 2009 · Penalty $12,000
Active - Class - 2
42d6.42n9.58y13.37m7.37d6.42d secure timer on back of controller jumper on 'sr relay 58 bearing leak 37 provide signage on door
Apr 28, 2009 · Penalty $2,500
Active - Class - 1
Work w/o a permit noted:at 2nd story north west corner commericial unit partitions erected mezzanine erected ceiling altered 3'x17'joists cut down approx 4" to 3"x13" sprinkler heads removed sprinkler system al
Apr 8, 2009 · Penalty $1,600
Active - Non-hazardous
Proper termination not provided for kitchen exhaust vent.in that exhaust unit terminates within ten feet of a residential window at the first floor east side of building.remedy:remove or provide proper terminat
Sep 2, 2004 · Penalty $200
Resolve - Hazardous
Sidewalk shed not adequately maintained : noted defects ( shed nraps 224 center up grand, thin down on baxter st ) missing & non hearing lighting throughout corners unsesured at se on baxter 7 x 8 danells separ
Sep 11, 2002 · Penalty $5,000
Resolve - Non-hazardous
Work without a permit. work noted: subdivided third floor into meeting room three offices, two bathrooms and a kitchen ett. without permit. remedy: stop all work immediatelu. obtain permit and approvals from b
Dec 7, 2001 · Penalty $2,500
Active - Hazardous
Failure to maintain building exterior .noted: at front (west) and rear least facade at various locations masonry is cracked,spalling , and missing support brackets seperately from chimney.remedy: erect a sidewa
Jun 9, 2000 · Penalty $800
Resolve - Non-hazardous
Work without a permit. noted: n/e comm space subdivided into 2 spaces by partition walls approx size 12'-0" by 8'-0" dba p.h. company. all work complete at this time. location: 1st fl comm n/e corner. remedy:
Jan 29, 1999
Resolve - Non-hazardous
Occupancy contrary to that allowed by the building department of records. alteration number 1575/88. noted first floor east space dbaph company approved size 12'-0" by 8'-0' at n/e corner subdivided from space
Jan 29, 1999
Resolve - Non-hazardous
46h,28l,
May 11, 1998
Resolve - Non-hazardous
50y,46k,40h, 40-remedy: noise on governor.
May 11, 1998
Resolve - Non-hazardous
Work without a permit noted: erected an awning at corner of bldg. at 1st floor level. awning constructed with plactic tarp with 1"x 2" woodlimber and metal angle now vertical supports screwed to plywood displa
Dec 31, 1997
Resolve - Non-hazardous
Illegal use in a manufacturing district noted commercial use extended to sidewalk at 1st fl. front, contrary to zoning resolution, requiringenclosure of the use in m-1-5b district dba 165 grand market inc.
Mar 22, 1997
Resolve
Complaints
No HPD complaints in our records
Sales history
| Date | Price | Type | Units |
|---|---|---|---|
| Jul 24, 2026 | $28,000,000 | Office buildings | 10 |
Building details
- Building type
- Office building (O5)
- Year built
- 1848
- Floors
- 6
- Residential units
- 3
- Building area
- 44,034 ft²
- Lot area
- 7,641 ft²
- Zoning
- M1-5/R10
- Community board
- 102
- Council district
- 1
- Block / lot
- 235 / 13
- Assessed value
- $3,848,850
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 165 Grand Street
Who owns 165 Grand Street?
The owner of record in NYC Department of City Planning PLUTO data is 224 Centre Realty LLC.
Does 165 Grand Street have violations?
NYC HPD has no housing violations on record for this property.
Is 165 Grand Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 165 Grand Street built?
City records list 1848 as the year it was built.
How many apartments are in 165 Grand Street?
It has 3 residential units and 10 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.