Violations at 30 Natick Street

Staten Island, NY 10306 · BBL 5-04373-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

14 DOB violations, newest first.

  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Public assembly none

    Pa-public assembly none

    Mar 16, 1989

    Dob violation - dismissed
  • Public assembly none

    Pa-public assembly none

    Mar 14, 1989

    Dob violation - dismissed

ECB violations

32 ECB violations, newest first.

  • Class - 2

    Failure to maintain building in code compliant manner.noted:there are several classrooms and other areas with excessive hangning combustiblematerials causing fire hazard and blocking view of important signage m

    Mar 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:at roof level,the metal railing/fencing used as a parapet safety is damaged at several areas and totally missing at some spots.this condition causes d

    Mar 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: there were several emergency lights that were not operational wh

    Mar 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Reissued 35347447r failure to maintain building walls or appurtenances note at roof lebel above gym and cafettria no guardrails maintain building exterior

    Aug 29, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner. use of prohibited door and/or hardware per bc 1008.18; 27-371(j). noted: there are several kick stops on many doors throughout the bldg, including classroo

    Aug 13, 2018

    Resolve
  • Class - 2

    Reissue: #35271122k failure to maintain building wall(s) or appurtenances. missing guardrails at roof. above the gym, cafeteria and auditorium areas. rmdy: maintain exterior building walls/appurtenances.

    Aug 13, 2018

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. noted: @ bulkhead staircase 'a' horizontal concrete cracks approx 10ft length in a concrete beam. rem: repair the beam.

    Aug 8, 2018

    Resolve
  • Class - 2

    Sec: 28-302.1. reissue# 35271122k. failure to maintain bldg walls or appurtenances. noted: missing guardrail @ roof level of gym area, cafeteria & auditorium. rem: install guardrail.

    Aug 8, 2018

    Resolve
  • Class - 2

    Reissue#35217079r failure to maintain bldg walls or appurtenances. noted: missing guardrail at roof level of gym area,cafeteria & auditorium also guardrails by main bldg's roof is loose & dislodged at several

    Jun 23, 2017

    Resolve
  • Class - 2

    Exit door not self-closing.noted:at 3rd flr,rm#307 & at 2nd flr rm#207,at 1st flr gym area and rm#123,the doors have defective in the hinges and closers.rem:comply with code.

    Oct 24, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner.noted:at roof level above cafe,audit and gym area,the roof has no guard metal members(lon g approx 180 ft)rem:comply with code.

    Oct 24, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner.noted:at bulkhead staircase(a)and electrical room,cracked concrete in the ceiling(long approx 10').rem:comply with code/repair the cracks.

    Oct 24, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner: interior. -at 1st floor lunch room exit 2a door, bottom of door frame rusted & splitting. -at basement in boiler room exit door, exit door & door frame rusted

    Apr 8, 2014

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner: interior. at main entrance wing, roll down gate in hallway does not have a safety stop to prevent unauthorized personel from rolling down gate. remedy: instal

    Apr 8, 2014

    Resolve
  • Class - 2

    Re-issue # 34980917j. exit door not self-closing. -at 1st floor vestibule exit 1, doors racked & not closing properly. -at 1st floor exits 4,5,6 & 7, doors racked & not closing properly. -at 1st floor auditoriu

    Apr 8, 2014

    Resolve
  • Class - 2

    Reissue 34980917j. f.p.s.c. doors racked 1st flr vestibule exits 4,5,6,7 and right side auditorium stage. remedy: maintain bldg.

    May 21, 2013

    Resolve
  • Class - 2

    27-371b plexi vision panels installed on door at various location throughout bldg rem: provide required glass panels

    Jun 7, 2012

    Resolve
  • Class - 2

    At 1st floor exit 4 5 6 &7 and door right of stage are racked preventing them from closing properly rem; repair or replace doors

    Jun 7, 2012

    Resolve
  • Class - 2

    Corridor smoke door is defective noted smoke door closer is defective causing doors not to be self closing located on the 3rd fl by room 308 rem: repair door closer

    Oct 27, 2011

    Resolve
  • Class - 2

    (r-023) @ gym, 2 of 12 light fixtures have no safety chain. remedy: install safety chains.

    Aug 4, 2010

    Resolve
  • Class - 2

    (r-023) classroom doors have plexiglass installed @ vision panels, eliminating the fire rating. locations: 306,309,101,104,105,107,110,112, 118, general office (right side). remedy: replace plan w/suitable

    Aug 4, 2010

    Resolve
  • Non-hazardous

    Reissue #34282180x failure to maintain: defects are spalling and cracked concrete at top curb of retaining wall at north side of play ground. remedy: repair defect.

    Jan 4, 2005

    Resolve
  • Non-hazardous

    *reissue* failure to maintain. noted: concrete has horizontal cracks and broken off pieces at retaining wall in schoolyard (s/e corner near batting./back stop). remedy: repair concrete.

    Jan 9, 2002

    Resolve
  • Non-hazardous

    Failure to maintain. noted: concrete cracked, pieces broken off of exterior steps near gate at north side. remedy: repair steps.

    Jan 9, 2002

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:the concrete encased steel girders and purlins of the cafeteria roof system,have severe cracks.remedy:provide engineers report.make all necessary repairs forthwith

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:in stairwell #4/5 between the 2nd & 3rd floors the wall tile is cracked.remedy:maintain bldg make all necessary repairs forthwith.

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:the plaster ceiling is crackjed and/or peeling in rooms #308 thru 314,208,209,211,108 and the principles office.remedy:maintain bldg make all necessary repairs forthwith

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:inside bulkhead #6/7 the block wall has cracked block and mortor joints.remedy:maintain bldg make all necessary repairs.

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:in the cellar the water shut off room and the crawl space under the auditorium are leaking ground water thru the foundation.remedy:maintain bldg.make all necessary repairs forthwit

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is:the concrete retaining walls on the north and east side of the soft ball area of playground is cracked and spalling.remedy:maintain retaining walls.make all necessary repairs forth

    Apr 4, 2001

    Resolve
  • Non-hazardous

    Failure to maintain.defect is1-the perimeter fence gates are missing on the w.side of the playgrd2-a sec.of chain link fence is missing on the perimeter fence.above the s.gates(playgrd)remedy:maintain bldg

    Apr 20, 2000

    Resolve
  • Hazardous

    Failure to maintain exterior noted 3 sections of 3-6x5-0 metal roof protections missing from the top roof one section 3-6x10-0 metal roof protection missing from the lower roof remedy make safe replace missing

    Jan 12, 1998

    Resolve