Violations at 481 Hylan Boulevard
Staten Island, NY 10305 · BBL 5-02993-0001 · Back to the property
HPD housing violations
9 HPD violations, newest first.
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 29, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Apr 16, 2021
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 16, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 23, 2016
Closed — Violation dismissed - ANon-hazardous
File with this department a registration statement for building.
Nov 6, 1996
Closed — Violation closed - ANon-hazardous
Properly repair the broken or defective facia board & soffit over u sty south wall or hylan blvd side.
Sep 6, 1990
Closed — Violation closed - ANon-hazardous
Repair the broken or defective rain leader east wall.
Sep 6, 1990
Closed — Violation closed - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box missing.
Sep 6, 1990
Closed — Violation closed - CImmediately hazardous
Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system 1 sty public hall and on boiler room door.
Sep 6, 1990
Closed — Violation closed
DOB building violations
2 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - active
ECB violations
14 ECB violations, newest first.
- Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. no certificate of correction on file for vio#39176542r . as of 6/18/2026., file a certificat
Jun 18, 2026 · Penalty $1,250
Active - Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. no certificate of correction on file for vio#39176541p as of 6/18/2026., file a certificate
Jun 18, 2026 · Penalty $1,250
Active - Class - 1
Observed in the basement install pvc waste lines and water lines for kitchen sink all work completed 100% no permits on file., obtain permit
Feb 9, 2026 · Penalty $2,530
Resolve - Class - 1
Observed in the basement a gas leak in the boiler room. pvc piping is used under the kitchen sink waste line. open ended waste lines, having corrosion on gas lines, having a future on gas line and having penetr
Feb 9, 2026 · Penalty $2,530
Active - Class - 2
Observed no extra sprinkler heads found at site. as per 903.5 of the fire code there shall be kept available at all times in the premises a supply of at least six extra sprinkler heads., repair and/or replace
Aug 23, 2024
Resolve - Class - 2
Observed no fresh air intake at boiler room, also no fresh air ventilation in any of the rooms housing the gas fired water heaters. also observed combustible storage in the boiler room., repair and/or replace
Aug 23, 2024
Resolve - Class - 2
I observed the exterior emergency lights power supply installed in low voltage plastic raceway.. this is not an approved raceway for electrical installations., provide approved conductors/equipment; use approve
Aug 14, 2024 · Penalty $500
Resolve - Class - 1
I observed in the main electrical room (2) two disconnects made inaccessible by the locked doors of the con edison c.t. cabinet. this is an immediate safety hazard as per ec 110.32 this prevents normal or emerg
Aug 14, 2024 · Penalty $1,600
Resolve - Class - 2
I observed in the main electrical room the installation of a new circuit breaker panel, conduits and wiring , no permit on file in dob records covers this work., obtain permit; obtain permit and call for inspec
Aug 14, 2024
Resolve - Class - 2
I observed throughout the basement the rooms with gas-fired heaters with no remote shutdown at the points of egress as required in mc 1006.8.1; mc 1006.8.1, comply with code; install remote shut-down.
Aug 14, 2024
Resolve - Class - 1
I observed throughout the basement passageway the failure to provide illumination at the points and along the path of egress.; bc 1006.1, comply with code
Aug 14, 2024 · Penalty $2,500
Resolve - Class - 2
Cracks in the facade and foundation located throughout building., repair and/or replace
Aug 14, 2024
Resolve - Class - 2
Observed in essence collection motel on the first floor in the bedrooms not having a sprinkler system which contrary nfpa13 k section 3.3.9, provide a system of automatic sprinklers where required
Aug 21, 2023
Resolve - Hazardous
4a
Jul 18, 1996
Resolve