Violations at 125-20 Sutphin Boulevard

Queens, NY 11436 · BBL 4-12051-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

14 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 17, 2019

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 13, 2017

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 15, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 29, 2015

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 17, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 4, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 24, 2010

    Dob violation - resolved
  • Facade facade optional

    Ll10/80-local law 10/80 - facade facade optional

    Jul 1, 1992

    Dob violation - dismissed

ECB violations

45 ECB violations, newest first.

  • Class - 2

    Failure to maintain building in code-compliant manner.noted:missing chunks of concrete on riser steps and missing non slip diamond tread plates on exterior walkway steps observed coned off upon inspection.rem:r

    May 26, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.no firestopping per bc 712.3;27-345.noted:missing firestopping in gas meter room on one large section of cmu block above entrance approximately 2ft x 3ft ob

    May 26, 2026 · Penalty $1,250

    Active
  • Class - 2

    Reissued on ecb#35725403k failure to maintain building in code-compliant manner.noted:fire rated classrooms and smoke doors not self-closingdue to binding,missing and or faulty hardware on classrooms 501,502,30

    May 26, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue on ecb#35725405y failure to maintain building in code-compliant manner.noted:at kitchen with commercial gas stove without an ansul or a fire suppression system observed upon inspection.rem:repair and/or

    May 26, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue on ecb#35725404m failure to provide ventilation to gas meter room per p115.6(1968 code);fsc appendix e(e4)(2014 code).noted:at cellar level at gas meter room remains without ventilation or fresh air int

    May 26, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35692576k date of issue: 10-24-2025. exit door not self-closing properly. at the time of inspection observed and noted at 1st floorexit-6 outside one exit door, at 1st floor cafeteria two exit doors, n

    Sep 26, 2025 · Penalty $625

    Resolve
  • Class - 2

    Reissue #35692556n date of issue: 10-14-2024. failure to maintain building in code-compliant manner. noted and observed at kitchen has a commercial gas stove in that place without an ansul system. remedy: repai

    Sep 26, 2025 · Penalty $3,125

    Active
  • Class - 2

    28-301.1. reissue #35692557p date of issue: 10-24-2024. failure to provide ventilation to gas meter room per p115.6(1968 code) fgc appendix e(e4)(2014 code) . at the time of inspection observed and noted at cel

    Sep 26, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35692558r date of issue: 10-24-2024. failure to maintain building in code-compliant manner. at the time of inspection observed and noted, defective hardware on interior fpsc doors missing door closure

    Sep 26, 2025 · Penalty $3,125

    Active
  • Class - 2

    Federal boiler has #3 king valve leaking water onto oil burner+vac system pump+float switch both leaking water+oil shutoff valve is missing@top of oil tank;correct violation+submit certificate of correction

    Aug 27, 2025 · Penalty $1,250

    Active
  • Class - 2

    Exit door not self-closing. noetd: exterior door at exit #6, rubs or saddle and jamb preventing it from closing properly. remedy: repair/replace door.

    Oct 24, 2024 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. emeregency lights defective/not working when tested at 1st fl stair 4,

    Oct 24, 2024 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: interiorfpsc doors missing closures or rached at rm #303b, 303c, 313c, 313e, 313g, 309 smoke door, 309b, 309c, 200x, 203a, 203c. mentioned doors ar

    Oct 24, 2024 · Penalty $625

    Active
  • Class - 2

    28-301.1 reissue #35663487x. failure to provide ventilation to gas meter room per p115.6(1968 code), fgc appendix e(e4)(2014 code). noted atcellar level gasmeter room, no fresh air ventilation provided. remedy:

    Oct 24, 2024 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35663488h. failure to maintain building in code-compliant manner. noted: kitchen has a commercial gas stove in place without an ansul system. remedy: repair/replace. provide ansul system.

    Oct 24, 2024 · Penalty $1,562

    Active
  • Class - 2

    Reissue: 35655436x failure to maintain building in code-compliant manner. commercial gas stove in place without an ansul system. remedy: repair and/or replace

    Aug 15, 2023 · Penalty $1,562

    Active
  • Class - 2

    Reissue: 35655437h miscellaneous violations cellar level gas meter room no fresh air intake vent. remedy: comply with code

    Aug 15, 2023 · Penalty $3,125

    Active
  • Class - 2

    Reissue: 35655438j failure to maintain building wall(s) or appurtenances. roof level on parapet wall coping stones have cracks and chipping on them about 15 stones with crack 9 have been replaced last year. als

    Aug 15, 2023 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain building wall(s)or appurtenances.noted:observed atseveral locations of parapet wall,the coping stones(approx.7 pieces/stores)have several cracks and are chipping away on the inside of the wa

    Jun 9, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    28-301.1 reissue#35561262h failure to provide ventilation to gas meterroom per p115.6(1968 code),fgc appendix e(e4)(2014 code).noted:observed at basement level-gas meter room does not have mechanical or natural

    Jun 9, 2022 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35561264l failure to maintain building in code-compliant manner.noted:observed in 1st flr kitchen,commercial gas stove in place without a ansul system.rem:repair and/or replace,install ansul system.

    Jun 9, 2022 · Penalty $1,562

    Active
  • Class - 2

    Reissue#35561265n failure to maintain building in code-compliant manner:illumination for exits,exit discharges & public corridors per bc 1006.1;27-381.noted:observed at 1st flr by stairway c emergency light box

    Jun 9, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    Missing bolts & dogs on front & rear doors on boiler,oil leak at burner,missing wiska switch for combustion air,vacuum pump leaking

    Nov 17, 2021 · Penalty $625

    Active
  • Class - 2

    Missing bolts & dogs on front & rear doors of boiler,oil leak at burner,missing wiska switch for combustion air louver,vacuum pump leaking

    Nov 17, 2021 · Penalty $625

    Active
  • Class - 2

    Sec. 28-301.1 unlawful display of artwork in corridors greater than 20% per fgdny 2008 code;fc 803.3.2. observed: at 2nd & 3rd floors on walls finished in wood in the corridor area there is excessive educationa

    May 11, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Exit door not self closing. observed: at 1st fl level,exit#5 is not closing properly when inspected. remedy: repair/replace door.

    May 11, 2021 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35495213z failure to maintain bldg in code compliant manner: observed: at 3rd fl smoke door#309;2nd fl,smoke door staircase'b';1st fl main entrance,smoke door did not close properly when inspected.

    May 11, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manners illumination for exits,exit discharges & public corridors per bc 1006.1;27-381. observed:existing emergency lights at 2nd fl;1st fl,light exit 2,light#6,stairc

    May 11, 2021 · Penalty $625

    Resolve
  • Class - 2

    Violation reissue#35495212r failure to maintain bldg in code compliantmanner: observed: 1st fl kitchen area commercial gas stove w/o ansual system. remedy: repair &/or replace.

    May 11, 2021 · Penalty $1,562

    Active
  • Class - 2

    Reissue#35495210n failure to maintain bldg in code compliant manner: no fire stopping per bc 712.3;27-345. observed: at basement level,electrical room,holes around the conduits w/o fire stopping. remedy: provid

    May 11, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Sec. 28-301.1 reissue#35495211p failure to provide ventilation to gas meter room per p115.6(1968 code),f6c appendix e (e4)(2014 code)observed: at basement,gas meter room does not have mechanical or natural vent

    May 11, 2021 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain bldg in code compliant manner. noted: at 2nd fl staircase'b',one door do not close properly due to hardware problem. remedy: repair/replace door.

    May 26, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. noted: at kitchen area,commercial gas stove w/no ansul system. remedy: provide ansul system to commercial gas stove.

    May 26, 2020 · Penalty $625

    Active
  • Class - 2

    Sec. 28-301.1 ressie#35433665x failure to provide ventilation to gas meter room per ph5.5(1968 code);fgc appendix e(e4)2014 code. noted: at gas meter room no fresh air ventilation provided. remedy: comply with

    May 26, 2020 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35433666h failure to maintain bldg in code compliant manner. no fire stopping per bc 712.3;27-345. noted: at electrical room,holes around the conduits w/no fire stopping. remedy: provide/maintain fire

    May 26, 2020 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. no fire stopping per bc 712.3/27-345. noted: at cellar electric meter room fire stopping missing/none w/opninings/holes in walls throughout in various location

    Jun 20, 2019

    Resolve
  • Class - 2

    Sec. 28-301.1 failure to provide ventilation to gas meter room per 115.6 fgc appendix e(e4)noted: at cellar gas meter room w/no fresh air intake/ventilation system. remedy: comply w/notice of violation.

    Jun 20, 2019

    Active
  • Class - 2

    59bb5,68m7,39m7,37t7,67x10,80m7-59bb5)brake maintenance tag expired. 68m7)maintenance control program missing. 39m7)crosby missing on spin out on top of car. 37t7)overhead door is unlabeled. 67x1)outside commun

    Oct 20, 2017

    Resolve
  • Class - 2

    Bc3307.6.5 failure to maintain sidewalk shed as required by code.notedsidewalk shed erected as per job#402892553 along exp1 has inoperable 4bulbs rendering affected area visibly dark creating potential risk rem

    Jan 8, 2016 · Penalty $400

    Active
  • Class - 2

    Reissue 35028670l failure to provide fresh air inlet per 27-766.noted @ cellar gas meter room,no fresh air inlet.rem comply w/ nov

    Jul 30, 2015

    Active
  • Class - 2

    27-766 - reissue 34981448k no fresh air intake at cellar gas meter room. rmdy: provide fresh air intake.

    Jul 29, 2013

    Active
  • Class - 2

    27-766 reissue #34921937r no fresh air inlet at cellar gas meter room no fresh air inlet rem: fresh air inlet rem: provide fresh air inlet

    Jun 27, 2012

    Active
  • Class - 2

    The gas meter room is lacking fresh air ventilation in the cellar level. remedy: provide/maintain fresh air ventilation.

    Jul 29, 2011

    Active
  • Class - 2

    Exteror concrete coping stone is cracked & spalling located at the roof level. remedy: repair &/or replace coping stones.

    Jul 29, 2011

    Resolve
  • Class - 2

    No fire stopping applied in the gas meter room (c-5) at cellar level. remedy: provide/maintain fire stopping in gas meter room.

    Mar 5, 2010

    Resolve