188-02 91 Avenue

Queens, NY 11423BBL 4-10443-0001Map

Owner of record: St Gerard Magella Rc

188-02 91 Avenue is a school building built in 1931 in Queens, 11423. The owner of record is St Gerard Magella Rc. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
12
ECB violations
33
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 12

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 3, 2015

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 28, 1993

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 28, 1993

    Dob violation - dismissed
Show 2 more ↓
  • Elevator elevatoroptional

    Mm

    Oct 26, 1989

    Dob violation - dismissed
  • Public assembly none

    Pa-public assembly none

    Jul 18, 1989

    Dob violation - dismissed

ECB violations · 33

  • Class - 2

    Re-issue #35724954m. failure to maintain, building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: in cellar, cafeteria and mechanical room e

    May 29, 2026 · Penalty $3,125

    Active
  • Class - 2

    Exit door not self-closing. noted: exterior exit doors not self-closing properly at cellar-"cafeteria exits", staircase "b" 1st floor. remedy: repair/replace door.

    May 29, 2026 · Penalty $625

    Active
  • Class - 2

    Reissue #35692273n 10/22/24. failure to maintain building in code-compliant manner. illumination for exits, exit discharges and corridors. noted: observed during inspection of cellar cafeteria light and mec roo

    Oct 3, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35674782m. failure to maintain building in code-compliant manner. noted: at cellar level room #004, storgae of two gas powered snowblowers. remedy: remove gas powered equipment from school building.

    Oct 22, 2024 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: at cellar level cafeteria 1-emergency with battery back up power

    Oct 22, 2024 · Penalty $625

    Active
  • Class - 2

    Reissue #35654918y failure to maintain building in code-compliant manner. noted: at cellar electrical room, illegal storage of misc. items. remedy: remove illegal storage from electrical room.

    Jun 8, 2023 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner. noted: at cellar, two gas powered snow blowers stored in room #004a. remedy: remove snow blowers from the cellar.

    Jun 8, 2023 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35495510p failure to maintain building in code-compliant manner.noted:observed at(cellar level)electrical meter room,illegal storageof combustible material.eg.cleaning supplies & equipment office suppli

    May 27, 2022 · Penalty $625

    Resolve
  • Class - 2

    Re issued #35495509h failure to maintain building in code compliant manner:no fire stepping per bc 712.3;27-345.observed:at electrical room and boiler room holes without fire stopping.remedy:provide/maintain fi

    May 19, 2021 · Penalty $5,000

    Resolve
  • Class - 2

    Re issue #35495510p failure to maintain building in code complaint manner.observed at electrical room illegal storage of combustilbe material office supplies and maintenance and cleaning equipment.remedy:repair

    May 19, 2021 · Penalty $6,250

    Active
Show 23 more ↓
  • Class - 2

    Re issued #35495511r exit door not self closing.observed at 3rd floor staircase next to room 304 is not self closing properly when inspected.remedy:repair/replace door.

    May 19, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.observed at third floor bathroom has water leaks from roof level with damage to acoustic ceiling panel.remedy:repair and or replace.

    May 19, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue#35414955k failure to maintain building in code compiant manner no fire stopping per bc 712.3;27-345.noted at electical room boiler room multiple holes w/ missing fire stopping provide/maintain fire stop

    May 13, 2020 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain building in code compliment manner noted at electrical roo illegal storage of buckets of chemicals floor polishes, ladders,tables chairs etc comply with notice of violations

    May 13, 2020 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35414954z exit door not self closing noted exit door at 3rd floor staircase next to room 304 is not self clsoing due to broken hardware repair and replace door

    May 13, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue #25272367l exit door not self-closing. door to stairase by room 304 is not self closing. rmdy: repair/replace door.

    Jun 7, 2019

    Resolve
  • Class - 2

    Reissue # failure to maintain building in code compliant manner: no fire stopping per bc 712.3; 27-345. fire stop missing in boiler/ electrical room. multiple holes. rmdy: provide/maintain fire stopping

    Jun 7, 2019

    Resolve
  • Class - 2

    Reissue:#35216641k-failure to maintain bldg in code-compliant manner:noted:at electrical room illegal storage of misc. items. observed boxes, chairs, tables, and ladders. remedy:repair and/or replace or remove

    Jun 19, 2018 · Penalty $6,250

    Active
  • Class - 2

    Reissue:#35216642m-failure to maintain bldg in code-compliant manner:no firestopping per bc 712.3;27-345-noted:electrical room, boiler room,various conduit hole missing firestopping. remedy:repair and/or replac

    Jun 19, 2018 · Penalty $5,000

    Resolve
  • Class - 2

    Reissue:#35216643y-exit door not self-closing-noted: exit door adjacent room 304 at 3rd floor missing closer. remedy: repair and/or replace

    Jun 19, 2018 · Penalty $3,125

    Resolve
  • Class - 2

    Reissue# 35216642m. failure to maintain bldg in a code compliant manner: no fire stopping per bc 712.3; 27-345. noted: @ electric meter room & boiler room multiple holes @ ceiling & walls due to pipe penetratio

    Aug 4, 2017

    Resolve
  • Class - 2

    Reissue# 35216643y. exit door not self closing. exit door by room 304 is not self closing, door is leading to staircase. rem: comply w/ summons. repair/replace door.

    Aug 4, 2017

    Resolve
  • Class - 2

    Reissue# 35216641k. failure to maintain bldg in a code compliant manner. noted: illegal storage of equipment & compliant material @ electrical meter room. rem: comply w/ summons.

    Aug 4, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. noted: at electrical room,illegal storage of misc items observed(boxes,chairs,tables,ladders) remedy: remove the storage out of the electrical room.

    Nov 16, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. no fire stopping per bc 712.3;27-345. noted: at electrical room,boiler room various conduit holes w/missing fire stopping. remedy: provide/maintain fire stoppi

    Nov 16, 2016

    Resolve
  • Class - 2

    Exit door not self closing. noted: exit door adjacent to room 304 @ 3rd fl missing closer. remedy: repair/replace door.

    Nov 16, 2016

    Resolve
  • Class - 2

    Exit door not self-closing. note: 3rd fl stwy 'b' door not closing and kick down door stop installed.corridor smoke door near room 302 not closing.2nd fl corricor near room 208 has kick down door stop installed

    Oct 16, 2015

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner.use of prohibited door and/or hardware per bc 1008.1.8; 27-371(g)the school bldg required stair to the roo fis latch pad locked.rmdy: provide legal hardware

    Mar 3, 2015 · Penalty $5,000

    Active
  • Class - 2

    Work does not conform to approved const docs & or approved ammends.note:sidewalk shed have been erected all around the bldg under permit #420949442-010-eq-sh 1)the columns @ the sws are standing 3-4ft away from

    Apr 4, 2014

    Resolve
  • Class - 2

    Failure to maintain building walls exterior facade allowing water to penetrate into classroom at third floor level rm 304 as well as exit staircase at 3rd and second for northeast exit near room 304.proceedin

    Jul 25, 2013 · Penalty $500

    Resolve
  • Class - 2

    Reissue #34927700x exterior metal grading on 91 avenue does not reach the window screen leaving an open gap of approximately 5" inches on the public sidewalk. noted:open gap is wide enough for pedrestan foot to

    Jun 1, 2012

    Resolve
  • Class - 2

    Exterior metal grading at the window well has a open spacing of appx 5"inches to the window screen located on 188 street and 91 ave street side rem: extend metal grading

    Aug 25, 2011

    Resolve
  • Hazardous

    Boiler room not a storage room clean gas burners not hot water piping connections to boiler corroded

    Sep 19, 1989 · Penalty $150

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
School building (W2)
Year built
1931
Floors
3
Residential units
—
Building area
32,300 ft²
Lot area
35,000 ft²
Zoning
R3X
Community board
412
Council district
23
Block / lot
10443 / 1
Assessed value
$11,617,200
Landmark / historic district
No

Questions about 188-02 91 Avenue

Who owns 188-02 91 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is St Gerard Magella Rc.

Does 188-02 91 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 188-02 91 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 188-02 91 Avenue built?

City records list 1931 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.