242-02 61 Avenue
Queens, NY 11362BBL 4-08286-0185Map
Owner of record: Douglaston Shopping Center Owner LLC
242-02 61 Avenue is a store building built in 1964 in Queens, 11362. The owner of record is Douglaston Shopping Center Owner LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 160
- ECB violations
- 75
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 160
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 3, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 16, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 2, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 24, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 24, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 24, 2021
Dob violation - dismissed - Elevator elevatorrequired
Cease use
Aug 28, 2021
Dob violation - resolved - Elevator elevatorrequired
Cease use
Aug 28, 2021
Dob violation - resolved - Construction other optional
At food store exposure# 3 brick facade wall has multiple cracks and out of plumb.
Aug 24, 2021
Dob violation - active - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Apr 29, 2021
Dob violation - active
Show 40 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2021
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2020
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2019
Dob violation - active - Retaining wall none
Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09
Oct 1, 2019
Dob violation - active - Retaining wall none
Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09
Oct 1, 2019
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 16, 2019
Dob violation - active - Construction other optional
Boro commissioner has issued swo for job # 421641931 due to superinten et withdrawal
Aug 30, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 18, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 18, 2018
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)
Mar 27, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Construction other optional
Stell height restriction bar located at ramp leading to upper level of shopping cneter has been dislocated due to bus imacting height bar at 242-02 61st avenue
Nov 20, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2017
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2016
Feb 16, 2017
Dob violation - dismissed
ECB violations · 75
- Class - 2
1rcny 103-09(e). failure to file a retaining wall condition assessmentreport by the deadline as required by 1rcny 103-09(e)(2) and (5). to date, the department has not recieved a retaining wall condition assess
Feb 25, 2025 · Penalty $6,250
Active - Class - 2
1rcny 103-09(e). failure to file a retaining wall condition assessmentreport by the deadline as required by 1rcny 103-09(e)(2) and (5). to date, the department has not recieved a retaining wall condition assess
Feb 25, 2025 · Penalty $6,250
Active - Class - 2
Failure to maintain. noted: observed at 1st floor of douglaston shopping center has numerous 2-4 inch pot holes throughout pavement., repair and/or replace
Aug 11, 2022
Resolve - Class - 2
Failure to maintain. noted: observed at exposure #2 (rear of food bazaar market) 61 avenue side there is approx. 50 linear ft of chain link fence collapsed and fallen onto grass., repair and/or replace
Mar 23, 2022 · Penalty $625
Resolve - Class - 1
Failure to maintain building in code compliant manner.noted garage ceiling in state of disrepair with rusted/rotted metal beams and columns throughout garage.remedy:repair and/or replace.
Feb 28, 2022 · Penalty $3,125
Resolve - Class - 1
Failure to comply with the commissioner's order contained in summons/violation#39046516h issued on 8/24/2021 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.work without a permit a
Feb 28, 2022
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. noted: observed at rear of bldg at loading docks the walls have several cracks at various locations. remedy: maintain exterior bldg wall.
Feb 24, 2022 · Penalty $3,125
Resolve - Class - 1
Failure to comply with the commissioners order contained in summons/violation#39046516h issued on 08/24/21 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.work without permit next
Dec 3, 2021 · Penalty $25,000
Active - Class - 1
Failure to maintain building walls or appurtenances.noted at exp3 of food store next to loading dock brick masonry wall has several cracks/step cracks approx 1 inch wide and wall is out of plumb.remedy:maintain
Oct 5, 2021 · Penalty $6,250
Resolve - Class - 1
Failure to maintain building in code compliant manner noted:garage ceiling in state of disrepair with rusted/rotted metal beams throughout of garage at 1st floor level concrete slab has damaged/chipped exposed
Oct 5, 2021 · Penalty $6,250
Resolve
Show 40 more ↓
- Class - 1
At 1st floor garage ceiling in disrepair condition metal beams corroded,paint chipping at multiple location. ceiling concrete coverage has cracks, exposed rebars.fence next to loading dock not properly secured.
Aug 24, 2021 · Penalty $1,250
Resolve - Class - 1
At food store exposure#3 brick facade wall has multiple cracks and out of plumb., maintain exterior building wall
Aug 24, 2021 · Penalty $2,500
Resolve - Class - 1
At 1st floor parking next to loading dock entrance i-beam and bottom part of metal column has been replaced.no permit found on dob record for this structural reinforcement., obtain permit
Aug 24, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to maintain building in a code-compliant manner. at the time of inspection, i observed chain link fence at above location has detached from the sidewalk has small hill down downward to the parking lot.
May 11, 2021 · Penalty $1,562
Resolve - Class - 2
Phone in cab inoperative. repair
May 6, 2021 · Penalty $1,562
Resolve - Class - 2
Hand rail in cab loose. secure. door gibs worn. replace.
May 6, 2021 · Penalty $1,562
Resolve - Class - 2
Oil leak machine room shut off valve. no dlm tag no the controller for 3.10.12. emergency stop switch no buzzer. alarm bell no buzzer.
Sep 22, 2020 · Penalty $625
Resolve - Class - 2
No dlm tag for 3.10.12. emergency stop switch no buzzer. alarm bell no buzzer.
Sep 22, 2020 · Penalty $625
Resolve - Class - 2
Failure to comply with commissioners order contained in summons/violation #35358030p issued on 04-10-2019,and to file a certificate of correction pursuant to 28-201.1 and 1 rcny 102-01(d)(2).an acceptible certi
Feb 11, 2020 · Penalty $1,250
Resolve - Class - 3
Work does not conform to approved construction documents and or approved amendments.noted: 1)3rd level liquor store inter.new partions and doors layout is contrary to plan # 4438369, drawings dated 2013-02-19.
Apr 10, 2019 · Penalty $500
Active - Class - 2
05i11-replace car door cracked glass.
Sep 14, 2015 · Penalty $250
Resolve - Class - 2
16i10 repair broken hoistway door glass.
Feb 18, 2015 · Penalty $250
Resolve - Class - 2
16i10 repair broken hostway door glass.
Feb 18, 2015 · Penalty $500
Resolve - Class - 2
2l10,2d7,64m7. 2l10-repair stop sw alarm; 64m7-provide nyc device#; 2o7-provide missing alarm switch cover @upper end.
Nov 17, 2014 · Penalty $1,250
Resolve - Class - 2
2l10,86e01,64m7. 2l10-repair stop switch alarm; 64m17-provide nyc device #; 86e01-steps not combing properly.
Nov 17, 2014 · Penalty $1,250
Resolve - Class - 2
2l10,64m7. 2l10-repair stop sw alarm; 64m7-provide nyc device #.
Nov 17, 2014 · Penalty $1,250
Resolve - Class - 2
2l10,64m7,97x10. 2l10-repair stop switch alarm; 64m7-provide nyc device #.
Nov 17, 2014 · Penalty $1,250
Resolve - Class - 1
Failure to maintain bldg in code-compliant manner. at the time of inspection i observed the drain piping "overhead" throughout the lower level garage falling apart due to piping not properly supported. also
Aug 10, 2012 · Penalty $1,000
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. at the time of inspection i observed f.d.c. connections/siamese piping throughout the lower level garage corroded and raptured. also noted overhead piping for
Aug 10, 2012 · Penalty $250
Resolve - Class - 2
Failure to safeguard all persons & property affected by const. operations."no smoking"signs within const.site not observed or inadequate in violation of nyc fire code 404/& fc 310.work at premises under job #42
Sep 6, 2011 · Penalty $1,200
Resolve - Class - 2
Failure to provide/post sign(s) at job site pursuant to subsection.noted:work at premises under job permit #420357688 w/o posted contractor's sign at premises.remedy:provide contractor's sign.
Sep 6, 2011
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations.(a)construction side is open to the public w/o const.fence installed.(b)approx. 10sqft of excavation approx.8ft deep w/o 45 degree
Sep 6, 2011 · Penalty $2,400
Resolve - Class - 3
Work does not conform to approved construction documents &/or approvedjob #410046793/a2 dated 918-08. noted: (1) plan shows counter where there is a full height wall. (2) walk in box location not as per plan.
Jun 29, 2011
Resolve - Class - 2
Failure to maintain bldg exterior noted at parking lot & dramp thru out premises found small sections at loose concrete thru out entire parking lot fallen and in danger of falling also observed holes w/ loose c
Jan 11, 2011 · Penalty $500
Resolve - Class - 1
Cease use97-l-10,97-o-02,89-i-11,100-b-11,91-x-10/97-l-10cease use as per accident investigation other items/97-o-02-clean down/89-i-11-damaged steps/100-b-11-step chain/91-x-10-buzzer
Nov 16, 2010 · Penalty $5,000
Resolve - Class - 2
Failure to maintain building wall(s) or appurtenancesat above locatio n at various locations on land lvl spalled concrete on sides of parking ramps in a state of disrepair spalling & falling concrete at various
Jun 6, 2009 · Penalty $2,500
Resolve - Class - 2
Failure to maintain building - exterior observed at inspection: broken,spalling concrete in various locations of 2nd level parking lot & rampway from 1st to 2nd levels,exposed rebar. also sidewalk & curb near
Apr 28, 2009 · Penalty $200
Resolve - Class - 1
Failure to maintain bldg in code compliant manner: lack of a system ofautomatic sprinklers where required per bc 903.2;27-954. upon inspection found dry sprinkler system removed from loading area/parking area
Jul 22, 2008 · Penalty $5,000
Active - Hazardous
Work w/o a permit hazardous approximately 450 linear ft by 5' high retaining wall installed (gabion wall). remedy: stop all work make site safe obtain permit.
Jun 4, 2008 · Penalty $800
Resolve - Hazardous
Failure to file tr-1 upon completion of controlled work. for job a2 #402175622 which permit has expired @ 8/14/06. work was completed and tr-1 sign off letter of completion not filed by architect as required.
Mar 31, 2008
Resolve - Non-hazardous
Failure to file tr-1 upon completion of controlled work. for job a2 #402199009 which permit has expired @ 8/14/06 work was completed and notsign off,letter of completion not filed as required by engineer or arc
Mar 27, 2008 · Penalty $350
Resolve - Non-hazardous
Sec.27-215. altered bldg occupied w/o valid c of o noted: c of o #401225456t was expired on 05/09/04 bldg now occupied w/o valid c of o. remedy: obtain valid c of o.
Oct 25, 2007 · Penalty $350
Resolve - Non-hazardous
Failure to comply with commissioners order to correct violating condition and file a certificate of correction with nyc dob for ecb notice of violating n#34539721k remedy: correct violating condition and file a
Oct 25, 2007 · Penalty $500
Resolve - Non-hazardous
Failure to maintain exterior bldg. wall. defect is : @ rear of shopping center timber retaining wall approx. 4' ht x 120'l deteriorated, rotten, curved, pullaway, bulged disconnected, missing section of structu
Oct 4, 2006 · Penalty $800
Resolve - Non-hazardous
Failure to maintain. noted: approx. 150 l.f. of chain link fence at 61ave beginning approx. 30'from 244 st toward douglaston blvd. are missing. some of remaining metal pipe posts leaning to the sidewalk.missing
Jun 7, 2005 · Penalty $800
Resolve - Non-hazardous
79i10/80i10/83o02 79)right hand.hand rail damaged-pinch points. 80)it step treads damaged 83)in the device dirty.
Jan 12, 2005
Resolve - Non-hazardous
80i10/83o2 80)repair or replace stop treads entire device 83)entire device dirty.
Jan 12, 2005
Resolve - Non-hazardous
80b01/ 76h12/ 73i12/ 74p17/ 80b gap between step & shirt left side 73i comb plate teeth damaged lower landing 74p call dob 212 566 5524 so proper insp can do made
Mar 11, 2003 · Penalty $350
Resolve - Non-hazardous
80j01/ 76h12/ 74p17/ 80j gap at right side lower landing 76h step tread's worn right side 74p call dob 212 566 5524 so proper insp. can be made
Mar 11, 2003 · Penalty $350
Resolve - Non-hazardous
67m11-74m07-74p17. 74-m-missing coure lowre mrewl 74-p call dob at 212-312-8947 for coaplete. insp cdh be dome.
Jul 3, 2001 · Penalty $350
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Store building (K6)
- Year built
- 1964
- Floors
- 3
- Residential units
- —
- Building area
- 296,432 ft²
- Lot area
- 547,200 ft²
- Zoning
- R4
- Community board
- 411
- Council district
- 23
- Block / lot
- 8286 / 185
- Assessed value
- $25,476,300
- Landmark / historic district
- No
Questions about 242-02 61 Avenue
Who owns 242-02 61 Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Douglaston Shopping Center Owner LLC.
Does 242-02 61 Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 242-02 61 Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 242-02 61 Avenue built?
City records list 1964 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.