147-22 73rd Avenue
Queens, NY 11367BBL 4-06682-0011Map
Owner of record: 147-22 Holding LLC
147-22 73rd Avenue is a religious facility built in 2019 in Queens, 11367. The owner of record is 147-22 Holding LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 15
- ECB violations
- 58
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 15
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Construction other optional
Boro commissioner has ordered work stopped for # 421247145 d ue to superintendent of construction withdrawal.
Aug 21, 2023
Dob violation - dismissed - Construction other optional
Applicant of record, alberto roman, pe surrendered all filing privileges. bc swo issued for job # 421247145. approx. 65% completed throughout, stop all work and make site safe.
Aug 15, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 18, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 9, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 9, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed
Show 5 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 9, 2019
Dob violation - dismissed
ECB violations · 58
- Class - 2
At the time of my inspection i observed supported scaffold installed and in use at exp#1 and 4 -45 feet high (7 frames x 6feet high and 1frame x 3 feet high) uppon checking dob records no permit was issued for
Jun 29, 2023
Resolve - Class - 2
At the time of my inspection -as per construction superintendent log book he visited the site at 7:00 am 6/29/23-numerous violations on site(supported scaffold installed without permit,workers without dob train
Jun 29, 2023 · Penalty $2,500
Resolve - Class - 1
At the time of my inspection of active new building construction job site uppon asking -jairon w osorio giroo and david love-they didn't poses a valid nyc dob training connect sst cards as per march 18 2023 . p
Jun 29, 2023 · Penalty $5,000
Active - Class - 2
At the time of my inspection of active new building job site -uppon request to see weekly toolbox talk log book-none was provided ,safety orientations records not dated
Jun 29, 2023
Resolve - Class - 2
Failure to maintain adequate housekeeping not pursuant to subsection as noted:at time of inspection at an active jobsite of a proposed 3 story building already at the bulkhead level.observed at exposure#1 at gr
Apr 25, 2023
Resolve - Class - 2
At time of inspection on a 3 story nb jobsite. i observed site closed and locked. observed 35 foot supported scaffold erected at exp.2. not maintained to code due to the following: planks not tied down, missing
Feb 3, 2023
Resolve - Class - 2
At time of inspection on a 3 story nb jobsite i observed construction fence at exp.1,2 and 4 not maintained to code - broken plexiglass on viewing panels, missing viewing panels and leaning panels at exp1 &2. r
Feb 3, 2023
Resolve - Class - 2
At time of inspection on a 3 story nb jobsite. i observed site closed and locked. observed large pile of debris at corner of exp.1 and 2 not stored in any container as per bc 3303.4.2. debris must be removed at
Feb 3, 2023
Resolve - Class - 1
At time of inspection on an active job site, i observed worker volodymyr synytsa smoking in the staircase at rooftop level of the building as he working (painting) in mention location.
Dec 20, 2022 · Penalty $6,250
Resolve - Class - 2
At time of inspection on an active job site, i observed permit holder failed to provide and maintain posting of no smoking signs on site within the building on all floors, as none was seen posted during the ins
Dec 20, 2022
Resolve
Show 40 more ↓
- Class - 1
Unsafe work, people working without fall protection on right side of building (exposure 2) full stop work order, provide/use safety belts.
Sep 28, 2022
Resolve - Class - 2
Jobsite fence not constructed or maintained pursuant to subsection. noted: at time of my inspection of a new 3 sty bldg,construction in progress bldg topped off,i observed the construction fence surrounding the
Mar 11, 2022
Resolve - Class - 2
Work does not conform to approved construction documents &/or approvedamendments. noted: at time of my inspection of a new 3 sty bldg,construction in progress,bldg topped off,i observed an excavation for a dryw
Mar 11, 2022
Resolve - Class - 2
Failure to perform proper concrete washout procedures at site. collection of containment. as noted: at time of my inspection observe concrete washout water on street w/all of the containment going to the man ho
Dec 1, 2021 · Penalty $2,500
Resolve - Class - 2
Sec. bc 28-104.7.11 additional information. as noted at time of inspection on an active jobsite observed in beams & column installed & on reviewing structural drawing some connection & detail was missing provid
Dec 1, 2021 · Penalty $625
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. at time of inspection on a 3 sty nb job site,i observed construction fence not maintained,leaning in sections,not paintained hunter green & n
Jul 14, 2021 · Penalty $500
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order.note:at time of inspection of a 3 story building under construction observed at exp #1 supported scaffold have been removed from past violation on
May 27, 2021 · Penalty $12,500
Resolve - Class - 2
Failure to maintain construction fence note:at time of my inspection observed the construction fence not maintain as required.the fence damage conditions loose laying to the public pedestrian walkway side.i als
Apr 1, 2021 · Penalty $2,500
Resolve - Class - 1
Sidewalk shed where require note:at the time of my inspection of a 3 story bldg w/active work in progress,i observed approx. 42'6 ft in height at exposure 1 inspector measure from top of parapet wall to ground
Sep 4, 2020 · Penalty $12,500
Resolve - Class - 1
Works does not conform to approved design-drawing.note:at the time of my inspection of a 3 story bldg w/work in progress.while inspecting basement observed basement ceiling is 13 ft.upon measured it is reveal
Sep 4, 2020 · Penalty $6,250
Resolve - Class - 2
Failure to safeguard all person and property affected by construction operation.note:at the time of my inspeciton of a 3 story building withno worker present at site i observed at exposure one a front clear wit
Aug 20, 2020 · Penalty $5,000
Resolve - Class - 1
Failure to file evidence of compliance with disability law.at time of inspection of an 3 stry bldg with construction work in progress,observed about 10 workers throughout the building.upon review the dept recor
Jul 30, 2020 · Penalty $12,500
Resolve - Class - 1
Provision of law:bc3307.7.3.job site fence no construction or maintained pursuant to subsection.note:at time of inspection of a 3 stry bldg expo 1 missing viewing panel.plexiglass failure to provide plexiglass
Jul 30, 2020 · Penalty $6,250
Resolve - Class - 1
Failed to ensure worker rescue site safety orientation.at time of inspection of a 3 story bldng with construction work in progress that consist of masonry and minor carpentry,upon request for site safety orient
Jul 30, 2020 · Penalty $12,500
Resolve - Class - 1
Failure to file evidence of compliance with worker compensation.at time of inspection on an 3 stry bldg w/ construction work in progress,observed about 10 worker in basement level,scaffold and on 1st fl lvl.upo
Jul 30, 2020 · Penalty $12,500
Resolve - Class - 1
Failed to ensure worker attened pre-shift safety meeting.at time of inspection of a 3 stry bldg with construction wrk in progress that consist of masonry and minor carpentry,upon request for pre-shift safety me
Jul 30, 2020 · Penalty $12,500
Resolve - Class - 1
Provision of law:bc3314.8.failre to institute.maintain safety equipment measure or temporary construction.note:at time of inspection of an 3stry bldg with construction work in progress,i observed at expo 1&2 ti
Jul 30, 2020 · Penalty $6,250
Resolve - Class - 2
Bc3308.5.1/indequate vertical debris netting missing or larg opening.at time of inspection on a 3 story nb i observe active jobsite with a competent person on site also observed various location with big openin
Jan 22, 2020
Resolve - Class - 2
Failure to maintain adequate housekeeping per section requirements at time of inspection on an 3 story nb i observed active jobsite with competent person on site also observed at ground leel and 1st floor a deb
Jan 22, 2020
Resolve - Class - 2
Const superintendent failed to perform duties per code observed: therewere 5 const workers on job site when i asked for the super of competent person noted nobody stepped up to say they were super or competent
Jan 6, 2020 · Penalty $5,000
Resolve - Class - 1
3314.1 failure to provide supp scaffold as per code.at time of my swo re-inspection,proposed 3story nb 2 sty deck level work in progress.observed,supp scaffold at exp#3 missing base plates, planks not tied,no w
Oct 3, 2019 · Penalty $6,250
Resolve - Class - 1
Work does not conform to site safety plan-at the time of inspection i observed work does not conform to the site afety plan provided. missing overhead protection at exp#2&4 in super structure phase. means of eg
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to safeguard all persons-at the time of inspection i observed planks set on blocks for workers to use instead of scaffold. the planks were at the height of window sill so workers could easily fall out
Apr 17, 2019 · Penalty $10,000
Resolve - Class - 1
Uncapped rebar-at time of inspection i observed uncapped rebar throughout site. the uncapped rebar in basement is an extreme hazard bacause there are no lights & someone can trip & bacome impaled on razor sharp
Apr 17, 2019 · Penalty $10,000
Resolve - Class - 1
Work does not conform to approved construction documents &/or amendments. at time of inspection i observed an elevator shaft constructed of 8"cmu. the plans provided show 10" cmu. this block also supports the
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3303.2.3.1 failure to provide temporary lighting for construction. at the time of inspection i observed no temporary lighting. the cellar was almost completely dark & is a hazard for workers,1st responders
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
No guardrails-at the time of inspection i observed missing &/or inadequate guardrails at exp#1,2,3&4. remedy: provide guardrails.
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
Construction superintendent failed in his duties-at the time of inspection i observed otabek rasulon failed in his duties as superintendent.1)he could not provide his dob issued superintendents card or osha car
Apr 17, 2019 · Penalty $10,000
Resolve - Class - 1
Sec. 330.14 failure to provide adequate drainage to prevent water accumulation-at the time of inspection i observed water accumulation in the elevator pit. remedy: provide drainage.
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to provide design drawings for construction equipment. at the time of inspection i observed a well wheel being used to hoist material to upper floors. no design drawings could be provided. this is a haz
Apr 17, 2019 · Penalty $1,250
Resolve - Class - 1
Failure to provide handrails. at time of inspection i observed missing&/or inadequate hardrails on permanet & temporary stairs. the temporary stairs leading to cellar had handrails constructed of 3/8" osb which
Apr 17, 2019 · Penalty $2,500
Resolve - Class - 1
Permit holder:failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1:observed jose pilcvh at a building site for which a construction superintendent
Apr 16, 2019 · Penalty $5,000
Active - Class - 1
Owner:failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1:observed nestor camilo at a building site for which a construction superintendent,ssm o
Apr 16, 2019 · Penalty $5,000
Active - Class - 1
Permit holder:failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1 observed nestor camilo at a building site for which a construction superintende
Apr 16, 2019 · Penalty $5,000
Resolve - Class - 1
Owner:failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1:i observed jose pilcvh at a building site for which a construction superintendent,ssm,o
Apr 16, 2019 · Penalty $5,000
Active - Class - 1
Permit holder: failed to produce for inspection the daily log that is required by bc 331.2 item 3. at time of inspection daily log wasn't provided upon request. remedy: comply with code
Apr 16, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to provide approved/accepted construction documents at jobsiteat time of inspection. at the time of inspection i observed masonry construction. detailed drawings of rebar schedule could not be provided.
Apr 14, 2019
Resolve - Class - 1
Bc2104.6 & bc3301.1 failure to provide a bracing for a wall erected more than 8ft high w/o bracing. as noted,at time of inspection,not active site,i observed cmu wall erected approximately 10-10.5ft high w/o ex
Dec 24, 2018 · Penalty $2,500
Resolve - Class - 2
Failure to provide approved/accepted plans construction documents at jobsite at time of inspection. as noted, at time of inspection, activesite first floor working level failure to provide approved/accepted
Dec 20, 2018
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction no guardrails. as noted, at time of inspection active site i observed no guardrails at too large openings at exp2, #4 opening
Dec 20, 2018 · Penalty $2,500
Resolve
Complaints
No HPD complaints in our records
Sales history
| Date | Price | Type | Units |
|---|---|---|---|
| Sep 11, 2026 | $7,000,000 | Religious facilities | 1 |
Building details
- Building type
- Religious facility (M1)
- Year built
- 2019
- Floors
- 3
- Residential units
- —
- Building area
- 14,164 ft²
- Lot area
- 7,600 ft²
- Zoning
- R4
- Community board
- 408
- Council district
- 24
- Block / lot
- 6682 / 11
- Assessed value
- $1,572,750
- Landmark / historic district
- No
Questions about 147-22 73rd Avenue
Who owns 147-22 73rd Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 147-22 Holding LLC.
Does 147-22 73rd Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 147-22 73rd Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 147-22 73rd Avenue built?
City records list 2019 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.