Violations at 37-16 Union Street
Queens, NY 11354 · BBL 4-04978-0046 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
11 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 3, 2014
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 31, 2012
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 28, 1993
Dob violation - dismissed
ECB violations
28 ECB violations, newest first.
- Class - 2
Observed outrigger system on roof level corner exposure 1-2 has been erected contrary to cd5 , drawings show double size h frame scaffolding ,erected triple size contrary to plans .creating hazards for workers
May 12, 2026
Resolve - Class - 2
New 14 story building . observed: active site ssm present also noted housekeeping issues on different floors and locations creating hazards for workers on site and contrary to building code
Feb 3, 2026
Resolve - Class - 1
New 14 story building . observed: upon inspection active site ssm present suspended scaffold on exposure 2,3 work in progress noted scaffold frame of outrigger system beam used contrary to designed on eq 200
Feb 3, 2026 · Penalty $2,500
Resolve - Class - 1
Work does not conform to approved construction documents and/or approved amendments.atoi i observed site conditions contrary to approved sspat exp#2 & exp 3 the distance outside jobsite fence less than 20 feet
Jan 3, 2026 · Penalty $2,500
Resolve - Class - 1
A 14 story building w/standpipe, i requested the electrical permit for the wiring of the alarm system for the standpipe, none was provided. dob records revealed that there was none in the system. as per code bc
Dec 18, 2025 · Penalty $400
Resolve - Class - 2
At the time of inspection active jobsite, upon reviewing the dob system for certification of correction for class #1 summons pertaining to the sidewalk shed at exposure#2 inspection reveal contractor failed to
Nov 25, 2025
Resolve - Class - 2
At the time of my inspection i observed mini crane installed at 6th floor exp#2 upon checking design drawings -it was installed contrary to plans-using multiple lines/choke lines+ manual winch rachet-as per pla
Nov 10, 2025
Resolve - Class - 2
At time of inspection i observed at exposure 1 the sidewalk shed deck not brought tight to the face of the building with missing debris netting. this causes unsafe conditions to pedestrians by exposing them to
Oct 30, 2025 · Penalty $2,400
Resolve - Class - 2
Bc 3303.3 at the time of my inspection of a 14-story new building, 10,998 sq ft, the site was closed with no construction activity. upon shouting around the perimeter and banging on the fence/doors, no watchpe
Oct 12, 2025 · Penalty $2,500
Resolve - Class - 2
Proposed 14 story nb with a approx. building footprint (sq. ft.)of 10,000. observed no construction activity takin place at the time of inspection. i walked around the outside of the building to take my picture
Sep 27, 2025 · Penalty $2,500
Resolve - Class - 2
Observed active jobsite w/ concrete cure blanket attached to vertical cable system on the 6th and 7th floor at expo #1. this condition is contrary to approved site safety plan, not shown as an approved method.m
Jul 25, 2025 · Penalty $1,250
Resolve - Class - 2
Observed active jobsite w/ approved site safety plan missing important site condition information pedestrian walkway not reflected along exposure #2. site safety plan is inadequate and missing site information
Jul 25, 2025 · Penalty $2,500
Resolve - Class - 1
Observed active jobsite currently at the 7th fl, proposed 14 story nb, 40 +/- ft away from public pathway expo #2 w/out any sidewalk shed installed for pedestrian protection. building's safety zone exceeds prop
Jul 25, 2025 · Penalty $10,000
Resolve - Class - 2
Observed active jobsite w/ steel columns approx. 2ft away from property line expo #4 erected more than 48 inches above adjacent property roof w/ out any roof protection installed. stop all work steel erection w
Jul 25, 2025 · Penalty $2,500
Resolve - Class - 1
Observed active jobsite with sidewalk shed installed, upon review of approved design drawings, multiple x bracing missing along expo 1 contrary to plan. also, observed overhead protection of ac unit at expo 3 b
May 23, 2025 · Penalty $625
Resolve - Class - 1
Observed active jobsite w/ large wooden shanti on 1st fl, upon request for manufacture spec for installation/ material fire rating, non-provided. also observed shoring on 2nd fl, no approved design drawings on
May 23, 2025 · Penalty $1,250
Resolve - Class - 1
3310.8.4.1- active concrete operations on 14 stories pouring 3-fl deck, csm #2334 not designated as per department requirements,failed to verify conditions 3310.02 (e)(3)(iii) & maintain record keeping of site
Apr 2, 2025 · Penalty $2,500
Resolve - Class - 1
Observed active concrete operations on major building 14 stories pouring 3-floor deck, upon reviewing the department records no designation of the concrete safety manager 1rcny3310-2 nor designation of concrete
Apr 2, 2025 · Penalty $5,000
Resolve - Class - 1
1rcny101-06 -observed structural steel assembly connections modified @ multiple locations w/ only tac-welding, missing braces enlargement of holes for strength bolts @ connection plates & base of i-beams, make-
Apr 2, 2025 · Penalty $625
Resolve - Class - 2
Rcny 20-08 fire hydrant use. observed hose connected to fire hydrant at exp#2 and running into the jobsite. the hose was connected directlyto the fire hydrant without the necessary reduced pressure zone backflo
Apr 2, 2025
Resolve - Class - 1
3305.2.2-observed structural steel assembly connections modified @ multiple locations w/ only tac-welding, missing braces while pouring concrete on 3 floor deck. no pe records, assessment reports for modificati
Apr 2, 2025 · Penalty $2,500
Resolve - Class - 1
Active operations major building 14 stories no construction superintendent nb issued 01-06-2025. designation of competent person letter on-site. permit q00847536-fo-ea -pw1 signed 04-24-2023 w/ cs & ssc. cs rem
Apr 2, 2025 · Penalty $10,000
Resolve - Class - 1
Bc 3303.4.10 obstruction of egress pathway.@active site in foundation phase in response to incident of worker injured observe area of incident per personnel encumbered with rebar material with active use of reb
Dec 31, 2024 · Penalty $2,500
Resolve - Class - 2
//bc 3310.5//at the time of my inspection observed support of excavation work in progress -uppon checking dob records as the application #q00847536 is in conjunction with new building under application #4217679
Mar 29, 2024 · Penalty $2,500
Resolve - Class - 2
At the time of my inspection of active job site 7 workers on site-uppon asking competent person for orientation log book -none was provided//maintain orientation log book on site
Mar 29, 2024 · Penalty $1,250
Resolve - Class - 2
At the time of my inspection of active support of excavation job site observed work contrary to plans-as per plans 2 separate l shape angles on sides of pile for lagging should be installed-installed one t-angl
Mar 29, 2024 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner.noted(1)the following doors are not self-closing.(1)school entry door,classrooms 1&2 office.(2)miscellaneous school illuminated exit sign not lit,no exit sign @
Apr 1, 2015 · Penalty $2,500
Resolve - Non-hazardous
Use of prohibited door roll down gate installed at west exit of meeting room. emergency light inoperative. failure to amend plans to show emergency light. remedy: amend plans.
Nov 28, 1988 · Penalty $310
Resolve