36-21 Prince Street
Queens, NY 11354BBL 4-04971-7505Map
Owner of record: Abic International Corp
36-21 Prince Street is a condominium built in 1955 in Queens, 11354. It has 10 residential units across 11 floors. The owner of record is Abic International Corp. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 20
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 20
- Class - 1
Insp.date071124 pswo issued no work exterior exp4 remedy provide ohp site condition unfinished concrete balcony 4 floor cantilever over exp4. at time of inspection new form work edge of balcony with 8 inch pour
Jul 16, 2024 · Penalty $5,000
Resolve - Class - 1
@11story nb site observe vertical safety netting missing+not maintained-at unenclosed perimeters above 2nd floor with material+debris within immediate vicinity,&active exterior work(curtain/window wall)@leading
Jul 11, 2024 · Penalty $10,000
Resolve - Class - 1
Site safety plan@11story nb site not in conformance to plans-mini crane on 4th fl balcony in use not on plan,&exposure#4 missing overhead protection+to code bc3309.13 for the incomplete exterior work(balconies,
Jul 11, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection i observed sws at exp#4 was not build as per code, missing horizontal bracings and posts out of plumb . failure to comply with sws spec. creates a hazardous condition for posible colapse.
May 20, 2024 · Penalty $2,400
Resolve - Class - 2
At time of my inspection on a active 11 story al jobsite,i ask ssc to provide sws 6 month inspection,safety straps log book,pre shift meatings for all workers and talk box talks , none was provided/availablecom
May 20, 2024 · Penalty $1,250
Resolve - Class - 1
During inspection of an 11 story building with the standpipe in place and painted, dob records revealed that there was no electrical alarm permit for the standpipe. permits are required to be obtained and maint
May 16, 2024 · Penalty $800
Resolve - Class - 1
11 str bldg. under construction/alt- site under active partial stop work order per nov #39527281j & complaint #4955742, with work stopped at exp#1, 4th flr & above, 10ft from balcony & setback leading edge. at
Apr 17, 2024 · Penalty $5,000
Resolve - Class - 1
Bc 3301.1.1 responsibility for safety. observed 1 worker on a 9th fl balcony at exp#1 & 4, working on a leading edge outside of the guard rails, with no fall protection. gc failed to fulfill their obligation to
Apr 17, 2024 · Penalty $5,000
Resolve - Class - 1
3307.6.5.3 sidewalk shed - responsibility for maintenance and use. observed sws at exp#4- also serving as fall protection over the exp#4 driveway- with multiple posts out of plumb and leaning, mudsills under se
Apr 17, 2024 · Penalty $5,000
Resolve - Class - 2
3307.6.4.4 vertical members and beams. observed sidewalk shed built over a driveway at exp#4, the majority of the vertical members/posts along the driveway lacked high visibility markings/displacement protectio
Apr 17, 2024 · Penalty $2,500
Resolve
Show 10 more ↓
- Class - 2
Bc 3307.4.3 vehicular traffic. observed vehicular access point (easement) at exp#3- leading to the driveway at exp#4- being accessed by at least 3 adjacent properies' parking lots with no protection of traffic
Apr 17, 2024 · Penalty $2,500
Resolve - Class - 2
3306.9.10.3 covering of floor openings.- upon inspection of an active 11 story alt construction site i observed floor openings with no hole covers provided about 6ft long and 10 inches wide n floors 6 through 1
Apr 8, 2024 · Penalty $2,500
Resolve - Class - 1
Upon inspection of an active 11 story alt construction site i observed missing and inadequate guardrail systems installed. approx 3ft high parapet wall on roof had no guardrails installed for fall protection at
Apr 8, 2024 · Penalty $5,000
Resolve - Class - 2
Upon inspection of an active 11 story alt construction site i observed a sidewalk shed installed at exposure 1 & 4. upon request to to see the latest 6 month sidewalk shed re-inspection letter i was provided wi
Apr 8, 2024 · Penalty $1,250
Resolve - Class - 1
I observed a sidewalk shed installed at exposure 1 contrary to approved drawings. missing 8ft bay @ exposure 1. 10ft shed extension in front of active garage/parking area on adjoining property not on drawings.
Apr 8, 2024 · Penalty $2,500
Resolve - Class - 2
Failure to maintain adequate housekeeping per section requirement. as noted: at time of inspection at an active jobite of a proposed 11 story building observed at exposure one 1st floor grade level failure to m
Oct 4, 2023 · Penalty $1,250
Resolve - Class - 2
Failure to maintain/display on site documents require by bc chapter 33. as noted: at time of inspection of a 2 story alteration at 7th floorlevel construction work in progress. i observed at exposure #4, floor
Sep 1, 2023 · Penalty $1,250
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guardians. as noted: at time of inspection of a 2 storybuilding at floor #7 level, on an active construction site. i obsereve
Sep 1, 2023 · Penalty $5,000
Resolve - Class - 1
At the time of my inspection proposed 11 stories building at 5th floor level, building approx.5252 sf. site closed and there was no construction activity. upon shouting at perimeter and banging on fence to aler
Aug 19, 2023 · Penalty $2,500
Resolve - Class - 2
At the time of my inspection of an active proposed 11 story jobsite i observed a sidewalk shed installed at exposure 3 & 4 that does not conform to approved submitted drawings. i observed at expos 4 an improper
Jun 15, 2023 · Penalty $1,250
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RM)
- Year built
- 1955
- Floors
- 11
- Residential units
- 10
- Building area
- 29,308 ft²
- Lot area
- 7,200 ft²
- Zoning
- C4-2
- Community board
- 407
- Council district
- 20
- Block / lot
- 4971 / 7505
- Assessed value
- $4,016,251
- Landmark / historic district
- No
Questions about 36-21 Prince Street
Who owns 36-21 Prince Street?
The owner of record in NYC Department of City Planning PLUTO data is Abic International Corp.
Does 36-21 Prince Street have violations?
NYC HPD has no housing violations on record for this property.
Is 36-21 Prince Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 36-21 Prince Street built?
City records list 1955 as the year it was built.
How many apartments are in 36-21 Prince Street?
It has 10 residential units and 12 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.