11-11 131 Street
Queens, NY 11356BBL 4-04011-0024Map
Owner of record: Spa Castle INC
11-11 131 Street is a public assembly built in 2005 in Queens, 11356. The owner of record is Spa Castle INC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 66
- ECB violations
- 23
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 66
- High pressure boiler boiler required
Violation issued-failure to file 2024 internal hgh pressure inspection
Nov 14, 2025
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 22, 2025
Dob violation - dismissed - High pressure boiler boiler required
Violation issued-failure to file 2023 external hgh pressure inspection
Sep 23, 2024
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2023 external hgh pressure inspection
Sep 23, 2024
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2023 internal hgh pressure inspection
Sep 23, 2024
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2023 internal hgh pressure inspection
Sep 23, 2024
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2023)
Jun 23, 2024
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2020 internal hgh pressure inspection
Jun 30, 2023
Dob violation - active
Show 40 more ↓
- High pressure boiler boiler required
Violation issued-failure to file 2020 internal hgh pressure inspection
Jun 30, 2023
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2021 external hgh pressure inspection
Jun 30, 2023
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2021 external hgh pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2022)
Jun 22, 2023
Dob violation - dismissed - High pressure boiler boiler required
Violation issued-failure to file 2019 external hgh pressure inspection
Jun 20, 2023
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2019 external hgh pressure inspection
Jun 20, 2023
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2022 internal high pressure inspection
Apr 25, 2023
Dob violation - active - High pressure boiler boiler required
Violation issued-failure to file 2022 internal high pressure inspection
Apr 25, 2023
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2021
Aug 21, 2022
Dob violation - active - Construction other optional
Structure rendered non-compliant. at time of inspection observed damage to have been sustained to 3rd floor interior stairwell and bulkhead roof consisting of fire proofing, sections of stucco/foam roof open due to fire. excessive equipment, inadequate drainage of water at roof. full vacate for entire premises forthwith.
Apr 25, 2022
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 5, 2021
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 5, 2021
Dob violation - resolved - High pressure boiler boiler required
Violation issued - failure to file 2017 internal high pressure boiler inspection
Mar 16, 2020
Dob violation - dismissed - High pressure boiler boiler required
Violation issued - failure to file 2017 internal high pressure boiler inspection
Mar 16, 2020
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 7, 2020
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 3, 2019
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2016 annual high pressure boiler inspection
Jun 22, 2018
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2016 annual high pressure boiler inspection
Jun 22, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2017
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2015 annual high pressure boiler inspection
Jun 23, 2017
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2015 annual high pressure boiler inspection
Jun 23, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2017
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 4, 2017
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 10, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 11, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 31, 2015
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed
ECB violations · 23
- Class - 1
Failure to submit the required parking structure initial observation report for an existing parking structure documenting the conditions of psid#q0004368 by the august 1, 2024 deadline. to date, the department
Oct 1, 2024 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code compliant manner. note: at time of inspection, observed improper drainage, failure to retain water as water is being discharged onto the sidewalk at exposure 4 at this locat
Feb 8, 2023 · Penalty $655
Active - Class - 1
Failure to maintain building in-code compliant manner. at time of inspection observed at commercial kitchen open uncapped 1" gas line, also observed 1" gas line reduced 1/2 residential flex gas line open uncapp
Apr 25, 2022 · Penalty $6,250
Resolve - Class - 2
50a,50b:fulton v.t. boiler,vmp 49.5,nb103061,gas fired. 50a safety valve inlet nozzle length excessive. reduce piping length and install structural support on discharge pipe. 50b no fixed access ladder for boil
Apr 25, 2022
Resolve - Class - 2
Fulton vmp-130 boiler missing relief on exchangers, missing fire damper on dryer vents, air cond in laundry room vented to boiler room, missing proving switch on comb. air, missing cleanout & drain at chimney.
Apr 25, 2022
Resolve - Class - 2
Fulton vmp-130 boiler missing relief on exchangers, missing fire damper on dryer vents, air cond in laundry room vented to boiler room, missing proving switch on comb. air, missing cleanout and drain at chimney
Apr 25, 2022
Resolve - Class - 2
50a,50b:fulton v.t. boiler,vmp 49.5,nb116002 gas fd 50a a reduced fitting is installed on a section of the safety valve inlet nozzle. removethe fitting and restore the nozzle to full pipe size for code complian
Apr 25, 2022
Resolve - Class - 1
Failure to maintain building in code-compliant manner. at time of inspection observed 1. approx: 2' exhaust flu for kitchen where excessive grease has accumulated without clean-outs. 2. 1st fl. exit discharge d
Apr 25, 2022 · Penalty $1,250
Resolve - Class - 1
Failure to maintain building in code compliant manner. at time of inspection i observed that sprinkler system was not pressurized, main sprinkler valve was closed., repair and/replace
Apr 25, 2022 · Penalty $1,250
Resolve - Class - 2
67x10,13i10. (67x10)repair emergency phone. (13i10)emergency light guard.
Sep 22, 2016 · Penalty $500
Resolve
Show 13 more ↓
- Class - 2
18b,50a,32a,b254. 50a-bottom of boiler show sign of overheating by discoloring of metal jacket investigate and repair if required.
Nov 9, 2015
Resolve - Class - 2
32a,50a,b254. 50a-evidence of water leak from cast iron sections; 50b-boiler appears to have substained damage from a delayed startup,removeside panels and check for damage and repair or replace and restore to
Nov 9, 2015
Resolve - Class - 1
47c,50a,11b,11c,50a,51. 50a-water gauge glass assembly defective and corroded; 11b-boiler blow down line corroded nipple entering boiler; 50a-boiler feed corroded and leaking near boiler (repair immediately &
Nov 9, 2015 · Penalty $1,000
Resolve - Class - 2
B254,11c,16,18,48b. #19a-piping on prestrol leaking; #11c,16,18 and 48.
Nov 9, 2015
Resolve - Class - 2
Occupancy contrary to that allowed by the c of o & bsa approval. noted: at parking structure,parking spaces reduced contrary to c of o #402179664f which states 1st fl for 52 cars. the parking has been reduced
Mar 17, 2015 · Penalty $600
Resolve - Class - 1
Failure to maintain bldg in code-compliant manner.note:approx 810 yds of loose uncontained garbage,cardboard & misc combustible debris, as well as overflowing rolloff containers wtih garbage debris & propane
Feb 22, 2013 · Penalty $1,000
Resolve - Class - 3
Occupancy contrary to that allowed by c of o #402179664f. noted: parking area for storage of wood,concrete bags & other material. remedy: comply w/c of o.
Jun 21, 2012 · Penalty $200
Resolve - Class - 3
Occupancy contrary to that allowed by c of o #402179664f. noted: storage of combustible materials & roll off container is being used insteadof off street parking spaces. remedy: conform to c of o.
Sep 20, 2010
Resolve - Class - 3
Occupancy contrary to that allowed by certificate of occupancy. noted: parking lot used for non construction storage. remedy: conform to c of o.
Jul 26, 2010
Resolve - Class - 1
Work w.o permit. at basement level,relocated exit door, pursuant to approved plan job # 402179664,at woman locker & removed/erected walls,around stairs. at 1st fl,removed/erected wall & installed water lines
May 12, 2009 · Penalty $1,600
Resolve - Class - 1
Sec 28-307.1 bc misc viol: obstruction of required work place exit. noted: egress compromised as follows: 1) at 1st fl the west side secondary exit obstructed with a preparation table, salad bar & a mobile ka
May 12, 2009 · Penalty $1,600
Resolve - Class - 1
Failure to maintain building in code-compliant manner. noted: at basement level, the interior stair going from basement to exit door, with respect to the riser/tread construction, 1st riser is higher than the
May 12, 2009 · Penalty $1,000
Resolve - Non-hazardous
Work contrary to approved plans nb 402179664.1-additional parking direction signs displayed at front curb contrary to drop off requirements.2-main sign contrary.3-8 vertical advertising banners displayed for
Jul 17, 2007 · Penalty $250
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Public assembly (P6)
- Year built
- 2005
- Floors
- 4.5
- Residential units
- —
- Building area
- 99,239 ft²
- Lot area
- 30,000 ft²
- Zoning
- M1-1
- Community board
- 407
- Council district
- 19
- Block / lot
- 4011 / 24
- Assessed value
- $8,471,700
- Landmark / historic district
- No
Questions about 11-11 131 Street
Who owns 11-11 131 Street?
The owner of record in NYC Department of City Planning PLUTO data is Spa Castle INC.
Does 11-11 131 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 11-11 131 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 11-11 131 Street built?
City records list 2005 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.