Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 3
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 28, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 28, 2021
Dob violation - dismissed - Unsafe buildings none
Ub-unsafe buildings none
Mar 25, 1997
Dob violation - dismissed
ECB violations · 29
- Class - 2
A six-story new building, observed part of the construction fence at exp#1 &4, reviewing the dob now and bis it is noticed that the construction fence permit q00284556 expired on 10/18/2022
Jan 4, 2023
Resolve - Class - 2
At the time of inspection observed a part of the construction fence at the corner of exp#1 & exp#4 adjacent to the sidewalk, creating a hazard for the people. as only part of the fence is remained at the site,
Jan 4, 2023
Resolve - Class - 1
At the time of inspection i observed, there was no handrails was provided on permanent staircase from 1st floor up to roof level, which was creating a hazardous condition on jobsite.
Aug 6, 2022 · Penalty $2,500
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order.as noted at time of inspection on an active construction site,observed at exp1,2,3,4 floor 1 to bulkhead cmu block masonry exterior wall with facad
Apr 7, 2022 · Penalty $5,000
Resolve - Class - 2
Work without a permit(new building permit expired)as noted at time of inspection on an active construction site,observed new building permithas expired on 4/2/2022.permit#421609361-01-nb.observed the gate door
Apr 7, 2022 · Penalty $3,125
Resolve - Class - 2
3314.8.2 failure to maintain debris netting as per code.at the time ofinspection,this was a 6 story residential building.construction site was closeed.as per perimeter inspection,i observed debris netting was n
Oct 19, 2021
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. as noted: at time of inspection on an active construction, 6 story concrete cast-in-place building masonry cmu block placemen
Sep 24, 2021 · Penalty $1,250
Resolve - Class - 2
3303.7.2 inadequate fire extinguishers.noted at time of inspection at an active jobsite,observed fire extinguishers on 1st and 4th floor missing yearly inspection tags and placed on the floor.and at 2nd floor f
Aug 24, 2021 · Penalty $620
Resolve - Class - 2
Failure to maintain embeded safety straps installation inspection log book on site.as noted:at time of inspection on active construction site of a 6 story concrete cast-in-place building,i observed concrete imb
Apr 30, 2021 · Penalty $1,250
Resolve - Class - 2
Expired construction fence permit at the time of inspection i observeda construction fence in place at expo#1.upon further inspection of dobnow and bis i saw that the construction fence permit expired on 12-21-
Mar 30, 2021
Resolve
Show 19 more ↓
- Class - 2
Jobsite fence not constructed or maintained pursuant to subsection.at the time of inspection i observed a construction fence onsite.all construction fences are to be maintained in proper condition which include
Mar 30, 2021
Resolve - Class - 1
Bc 3307.4.7 work on storage zone. note-at the time of my inspection ofa 6 story new building. i observed dumpster container on the street adjacent to sidewalk shed and not enclosed w/ a fence,a solid barrier ex
Mar 19, 2021 · Penalty $625
Resolve - Class - 2
Temporary construction equipment on site expired permit at the tim eof my inspection i observed upon researching bis and dob now that the construction fence on site had a permit that expired on 12-21-2020
Feb 18, 2021 · Penalty $620
Resolve - Class - 1
3309.10 failure to protect adjoining properties during const or demo operation @time of insp on active 6stynb constsite notice@exp4 of constsite contractor failed to maintain/institute protection for property r
Jan 29, 2021 · Penalty $1,250
Resolve - Class - 1
3303.11 failure to maintain adequate means of egress during const @time of insp on active 6stynb constsite notice@5fl stairs in or out were being obstructed by rebar >4'h,contractor failed to maintain adequate
Jan 29, 2021 · Penalty $2,500
Resolve - Class - 1
No site specific formwork design drawings present per3301.7 @time of insp on active 6stynb const in framing of superstructure,when request was made for drawings for formwork&opening for temp stairs competent pe
Jan 29, 2021 · Penalty $2,500
Resolve - Class - 1
Work doesn't conform to approved const docs &/or approved amendments.@time of insp on active 6stynb const site.notice that plans/drawings for sidewalk shed wasn't as per what contractor erected on site.plans ca
Jan 29, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to institute/maintain adequate guardrails onsite @time of inspon active 6stynb constsite notice@5flexp1&interior core on 5fl@stairs missing/inadequate guardrails.this is dangerous in that workers were f
Jan 29, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to obtain temporary construction equipment permit at time of inspection on a proposed 6 story new building currently at 2nd floor level observed a sidewalk shed in place a exposure#1.upon further resear
Nov 25, 2020 · Penalty $1,280
Resolve - Class - 2
3309.14 window protection at time of inspection on a proposed 6 story nb currently pouring at 2nd leve observed at exp #2 & 4 missing windowprotection for occupied bldg at 1st & 2nd fl,currently the site pourin
Nov 18, 2020
Resolve - Class - 2
Construction superintendent failed to do duties as per code at the time of a proposed 6 story nb inspection currently pouring 2nd fl observed the following violating conditions in which the site was issued a fu
Nov 18, 2020 · Penalty $2,500
Resolve - Class - 1
Work doesnot conform to approved/accepted documents ssp at time on a proposed 6 story nb currently pouring 2nd fl level observed from work for 2nd fl extending over lat.line fence at exp.#4 above adjacent bld
Nov 18, 2020 · Penalty $2,500
Resolve - Class - 1
Failure to provide pedestrian protection for sidewalks & walkway.at the time of inspection of a proposed 6 story nb i observed concrete pouring operation in progress,2nd floor deck was being powered observed
Nov 18, 2020 · Penalty $10,000
Resolve - Class - 1
Bc3301.13.1 inadequate site safety plan at the time of inspection of a6 story nb currently pouring operation in progress.at exp #1 observed a concrete truck concrete pump & washout box in roadway w/the pump out
Nov 18, 2020 · Penalty $2,500
Resolve - Class - 1
Bc3307.4 warnig signs barriers & signals at times of inspection on a proposed 6 story nb currently pouring 2nd fl level,observed concrete pouring operation in progress.at exp#1 observed a concrete truck concr
Nov 18, 2020 · Penalty $2,500
Resolve - Class - 1
Bc1704.1.2 responsibility of the special inspection agency- independence at time of inspection on a proposed 6 story nb currently pouring 2nd fl level observed concrete pouring operations in progress & various
Nov 18, 2020 · Penalty $2,500
Resolve - Class - 1
Permit holder failed to ensure that workers received site safety orientation.at the time of inspection of a 6 stroy nb currently pouring 2ndfl level.i observed more than 7 workers in the site performing pouring
Nov 18, 2020 · Penalty $2,530
Resolve - Class - 2
Fence.note:at the time of my inspection of a demolition job site,i observed missing portions of construction fence at exposure 2(near)and exposure 3,creating a hazardous condition for non construction persons a
Feb 11, 2020
Resolve - Class - 2
Failure to maintain building wall or appurtenanas. noted: vacant bldg & missing leader at front & 2 leader at rear terminated open onto yard & not connected to storm snub & maintain ex\system.
Jul 30, 2014
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D1)
- Year built
- 2020
- Floors
- 6
- Residential units
- 10
- Building area
- 16,192 ft²
- Lot area
- 5,000 ft²
- Zoning
- R7B
- Community board
- 404
- Council district
- 25
- Block / lot
- 1567 / 6
- Assessed value
- $1,161,450
- Landmark / historic district
- No
Questions about 90-12 Whitney Avenue
Who owns 90-12 Whitney Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 9012 Whitney INC..
Does 90-12 Whitney Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 90-12 Whitney Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 90-12 Whitney Avenue built?
City records list 2020 as the year it was built.
How many apartments are in 90-12 Whitney Avenue?
It has 10 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.