What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 10

  • Construction other optional

    Borough commissioner has ordered work stopped for job #421715184 due to general contractor of construction withdrawal.

    May 23, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 2, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 2, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 2, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 15, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 18, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 18, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 18, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 26, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 26, 2021

    Dob violation - active

ECB violations · 23

  • Class - 2

    At time of inspection, observed construction fence in place, upon review of department records it was noted that construction fence permit #q00402298 expired on 12/14/2025. obtain and maintain all required perm

    Jan 22, 2026 · Penalty $6,250

    Active
  • Class - 2

    At time of inactive jobsite observed temporary construction fence in place with expired permit under q00402298-i1-fn. upon review department of records revealed that the fence permit has been expired since 01/2

    Mar 24, 2025 · Penalty $6,250

    Active
  • Class - 2

    Failure to maintain jobsite fence.note:ato my insp observed const fence damage conditions not maintained as required.fence@exp1 walkway siteloose,leaning to pedestrian walkway side nails come out created unsafe

    Feb 17, 2022 · Penalty $500

    Active
  • Class - 1

    Failure to maintain/display required documents as per chapter 33. noted: at time of my inspection of an alteration type -1,construction in progress,i observed a large excavated area @ exp#3 approx 18"long x 16f

    Nov 10, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to provide protection at sides of excavation. noted: at time of my inspection of an alteration type-1,2 sty bldg,construction in progress,approx 5 workers on site,upon entering the site,i observed an ex

    Nov 10, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to notify the dept prior to the commencement of earthwork. noted: at time of my inspection of an alteration type-1,2 sty bldg,construction in progress,upon entering the site,i observed a large excavatio

    Nov 10, 2021 · Penalty $2,500

    Active
  • Class - 2

    Failure to provide approved/accepted construction documents &/or approved construction documents at job site at time of inspection. noted: @time of my inspection of an alt-type-1,2 sty bldg,construction in prog

    Nov 10, 2021 · Penalty $312

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction equipment-no guardrails. noted: at time of my inspection of an alteration type-1,2 sty bldg,construction in progress,approx 5 wo

    Nov 10, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Sec. bc3303.2.4 no sanitary facilities on site. noted: at time of my inspection of an alteration type-1,construction in progress,approx 5 workers on site,upon walking the entire site,i was unable to locate a re

    Nov 10, 2021 · Penalty $625

    Resolve
  • Class - 2

    Construction superintendent failed to perform duties per code. noted: at time of my inspection of an alt type-1,2 sty bldg construction in progress for which the above named respondent is the const. superintend

    Nov 10, 2021 · Penalty $5,000

    Active
Show 13 more ↓
  • Class - 2

    Failure to maintain adequate housekeeping. note:at time of inspectin of active job site observed excessive amount of construction debris stored at exp #1 leaning on construction fence creating hazardous conditi

    Sep 28, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Temporary construction equipment onsite-expired permit.noted at time of inspection at a non-active jobsite.upon reviewing bis/dob now observed jobsite construction fence permit#q00402298-1-fn expired on 7/31/21

    Aug 26, 2021 · Penalty $640

    Resolve
  • Class - 1

    Bc 3309.1 failure to protect or adequately protect adjoining properties during construction operations.at time of inspection of a 2 story building under alteration i observed new wood framing at the roof level

    Jun 25, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Work does not conform to approved construction documents.at time of inspection on a 2-story alteration site currently in demo phase observed.load-bearing wall in cellar level had been removed & the wooden beam

    May 27, 2021 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to communicate required information to workers during pre-shift safety meetings.at the time of inspection of 2 story building with partial demolition and extention observed 3 workers and competent perso

    May 27, 2021 · Penalty $25,000

    Active
  • Class - 2

    Work does not conform to approved/accepted documents-ssp at the time of inspection of 2 story building with partial demolition and extentionobserved 4 workers onsite.upon review of provided site safety plan it

    May 27, 2021 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain/institute safety measures;guardrails at time of inspection on a 2-story alteration site currently in demo phase observedmissing guardrails at exp.#1 roof level + inadequate guardrails at exp

    May 27, 2021 · Penalty $12,500

    Resolve
  • Class - 1

    Failure to maintain a record of orientations performed at worksite.at time of inspection on a 2-story alteration site currently in demo phase observed that the demo was not conforming to approved plans.upon rev

    May 27, 2021 · Penalty $25,000

    Active
  • Class - 2

    Bc3301.6.1 no design drawing for temporary sharing at time of inspection on a 2-story alteration site currently in demo phase observed partial demolition contrary to approved plans due to the load bearing wall

    May 27, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Sec. 3301.13.1 site safety(not on site). at the time ooof my inspection on an active job site,i observed workers engaged in construction activities on the 1st & 2nd fl level. upon request for the site safety pl

    Feb 19, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain/display on site documents required by chapter 33. at the time of my inspection of an active jobsite,i observed workers engaged in construction activity on the 1st & 2nd fl level. upon reques

    Feb 19, 2021 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per section requirements. atthe time of my inspection on an active job site,i observed tha the permit holder failed to maintain adequate housekeeping which was seen at

    Feb 19, 2021 · Penalty $12,500

    Active
  • Class - 1

    Sec. 3303.7.2 no &/or inadequate fire extinguishers on site. at the time of my inspection at an active job site,i observed that the permit holder failed to provide & maintain fire extinguishers on site as requi

    Feb 19, 2021 · Penalty $12,500

    Active

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Two-family home (B2)
Year built
1925
Floors
1
Residential units
2
Building area
2,172 ft²
Lot area
2,500 ft²
Zoning
M1-2/R5B
Community board
401
Council district
26
Block / lot
601 / 25
Assessed value
$76,560
Landmark / historic district
No

Questions about 36-23 32 Street

Who owns 36-23 32 Street?

The owner of record in NYC Department of City Planning PLUTO data is Perez Maria T.

Does 36-23 32 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 36-23 32 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 36-23 32 Street built?

City records list 1925 as the year it was built.

How many apartments are in 36-23 32 Street?

It has 2 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.