27-15 27 Street
Queens, NY 11102BBL 4-00575-0040Map
Owner of record: Shaad Realty LLC
27-15 27 Street is an elevator apartment building built in 2019 in Queens, 11102. It has 10 residential units across 5 floors. The owner of record is Shaad Realty LLC. HPD has recorded 2 housing violations here, most recently on May 11, 2026.
- HPD violations
- 2
- DOB violations
- 2
- ECB violations
- 21
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 2
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
May 11, 2026
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 18, 2024
Closed — Violation dismissed
DOB building violations · 2
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 14, 2021
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 9, 2010
Dob violation - dismissed
ECB violations · 21
- Class - 2
Work does not conform to approved construction documents and/or amendments. noted: at time of my inspection of a new 5 story building construction in progress, building topped off, i observed supported scaffold
Oct 1, 2021
Resolve - Class - 2
Work afterhrs w/o variance permit contrary to 28-105.2.5 noted:atoi observed 4workers working in nb site on sunday 6/27/21 w/o obtaining variance permit.obtain variance permit.
Jun 27, 2021 · Penalty $1,250
Resolve - Class - 2
Housekeeping note:at the time of my inspection of a 5 story building with workers onsite i observed that there was large amounts of debris and construction material at the rear yard ex#3 large amounts of debris
May 13, 2021
Resolve - Class - 2
3301.13.1 28-110.1 inadequate site safety plan noted:at time of my inspection of a new 5 story building in progress,building topped off i observed the rear of the property had an exit into the adjoining propert
Jan 20, 2021 · Penalty $625
Resolve - Class - 2
Pedestrian protection does not meet code specifications.noted:at time of my inspection of a new 5 story building construction in progress building topped off i observed the sidewalk shed at exposure#1 did not c
Jan 20, 2021 · Penalty $2,400
Resolve - Class - 1
Unqualified worker performing work on supported scaffold noted:at timeof my inspection of a new 5 story building in progress building toppedoff i observed 3 workers on the supported scaffold at exp#3(efran guar
Jan 20, 2021 · Penalty $5,000
Resolve - Class - 2
3309.1 failure to protecting adjoining structures(general)noted:at time of my inspection of a new 5 story building construction in progress,building topped off i observed the balconies of the adjoining property
Jan 20, 2021 · Penalty $625
Resolve - Class - 2
Failure of permit holder to provide inspection access to and/or expose ongoing construction or work on an active and permitted worksite., provide access and/or exposure to ongoing construction or work
Feb 26, 2020 · Penalty $2,500
Resolve - Class - 2
The exterior walls on exposure #4 from 1st. to 4th. floor were installed without r-8 continual insulation which did not match comcheck on page en-106.01. it is permitted to perform work to correct violation, be
Jan 2, 2020 · Penalty $625
Resolve - Class - 1
Failure to instistute/maintain saftey equipment measures no guardrails at the time of my inspection 5 sty nb active site 4 sty lvel work in porgress observed guardrails system on 4 sty deck level missing/inadeq
Nov 4, 2019 · Penalty $2,500
Resolve
Show 11 more ↓
- Class - 1
Failure to saefguard all persosn and propertyies at the time of my inspection 5 sty nb actiev site 4 sty level work in progress observed workers perform their job by leaidng edge without any fall protection
Nov 4, 2019 · Penalty $10,000
Resolve - Class - 2
3301.13.13=failure to provide adequate job site logs at the time of my inspection 5 sty actiev nb site 4 sty level work in progess upon request for const super job site logs hwile const super was not at site ob
Nov 4, 2019
Resolve - Class - 2
3301.7=drawong design at the time fo inspection 5 sty nb actiev site 4 sty level work in progress bserved platform on elevator shaft at 4 floor openeed for use materialds on platform upon request for engineer d
Nov 4, 2019
Resolve - Class - 1
3301.12=safety meetinsg records/logs at the time of inspetcion 5 sty nb actiev site 4 sty level work in progress observed workers working in dangerous conditions upon request for if the workers has any safety m
Nov 4, 2019 · Penalty $2,500
Resolve - Class - 2
Bc3301131-construction superintendent failed to provide site safety plan.at time of inspection new building 5 story at 3rd floor level upon request ssp to superintendent none was provide,creating a hazard condi
Sep 30, 2019
Resolve - Class - 1
Bc 3301.13.12 failure to designate competent person. at the time of inspection at a 5 story nb i observed the job site was open and construction activity ongoing. i asked for the construction superintendent and
Sep 23, 2019 · Penalty $2,500
Resolve - Class - 2
Bc28-116.2.3/failure to provide an adequate inspection program tr3 misdesign for l.w.c.as noted at time of my inspection active site 2nd floor working deck,i observed failure to provide trs i.w.c.mix design.rem
Jul 11, 2019
Resolve - Class - 2
Failrue to provide adequate housekeeping per sections,as noted at timeof inspection active site,i observed debris of wooden plywood,wood pieces,garbage bags at expo#3 grade level results in unsafe conditions.re
Jul 11, 2019 · Penalty $625
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. as noted: at time of inspection at an active construction site. observed at exp #1, #3 foundation wall, steel lintel beam pla
Jan 25, 2019 · Penalty $620
Resolve - Class - 1
Deficient design- the respondent design applicant failed to meet the design requirements for the underpinning of an adjacent 1 story garageat 27-05 27 street, queens. in addition, the applicant failed to have
Aug 31, 2018 · Penalty $2,500
Resolve - Class - 2
Work w/o permit. expired permit. noted: construction fence installed with permit #421255288 issued on 12/29/16 and expired on 12/29/17 no valid permit at time of inspection. rmdy: renew permit.
Jan 26, 2018 · Penalty $400
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D1)
- Year built
- 2019
- Floors
- 5
- Residential units
- 10
- Building area
- 7,489 ft²
- Lot area
- 3,235 ft²
- Zoning
- R6B
- Community board
- 401
- Council district
- 22
- Block / lot
- 575 / 40
- Assessed value
- $570,600
- Landmark / historic district
- No
HPD registration #434160, last renewed Jul 22, 2025.
Questions about 27-15 27 Street
Who owns 27-15 27 Street?
The owner of record in NYC Department of City Planning PLUTO data is Shaad Realty LLC.
Does 27-15 27 Street have violations?
Yes. NYC HPD has recorded 2 housing violations at this property.
Is 27-15 27 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 27-15 27 Street built?
City records list 2019 as the year it was built.
How many apartments are in 27-15 27 Street?
It has 10 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.