roofy

Violations at 29-10 21 Street

Queens, NY 11102 · BBL 4-00537-0043 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

5 DOB violations, newest first.

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 11, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 12, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed

ECB violations

26 ECB violations, newest first.

  • Class - 2

    Bc 3314.1 active site observed worker on top of supported scaffold. scaffold missing guardrail and not fully planked. maintained scaffold as per code

    Jun 7, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection, i observed no handrails throughout all 8 floors at stair "a" and stair "b". also, no control access zone were temporarily in place to close either one of the stair case should work being

    May 14, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    3303.11.2 stairs during building construction. observed 8 str/80 ft nb with stairs not open for access btwn 1st and 2nd flrs, and stair snot poured btwn 2nd and 3rd flrs, with only a single means of egress/ingr

    Jul 19, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    3306.9.10.3 covering of floor openings. observed floor openings in the slab from 2fl thru roof- approximately 2ft x 2ft in size and larger- covered with loose boards of plywood- hole covers were not secured or

    Jul 19, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Obsvd sup scaf at exp#3 at 2fl up to rf w/ conditions contr to dob-aprvd scaf dwgs- mid section of scaf with frames aprox 10ft apart on either side of balcony connected with pipe and clamp and some plfms connec

    Jul 19, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    Observed 8 str/80 ft nb, topped off, with balconies from flrs 3 thu 8 at exp#3 lacking guard rails or permanent railings, and with the doors to all of these balconies being unlocked, many of them open at time o

    Jul 19, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Obsvd 8 str/80 ft nb, topped off with unfinished stucco and parapet work at the 2fl setback at exp# 3 + 8fl setbacks and rf bulkhead at exps#1&3, at corners of exp#2, & up to 10ft back. the exp#2 adj prpty lack

    Jul 19, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    3303.8 standpipe systems during construction, alteration or demolition. observed 8 str/80 ft nb with the 75ft mark falling within the 8th (occupiable) floor. the standpipe was not painted red at the 8th flr and

    Jul 19, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Bc3301.2 observed electrical lines runs into weatherhead cap with wires exposed and no insulations or preventive measures of exposed lines near scaffold,bc3314.4.4.12 stipulates clearance between scaffolds and

    Apr 18, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Bc3308.6.1.4.1 scaffold alt installed below 7fl slab w/deck at 6fl,remaining form strip operations 7fl,8fl,roof slab,scaffold deck to be even at level where horizontal nets would be required perbc3308.6 and not

    Apr 18, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Observed needle beams exp4 with tie down and reshore at inboard end of beam and no tiedown or reshore near fulcrum point location of beam.bc3314.14.1 stipulates beam shall be secured against movement and shall

    Apr 18, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Reviewed pe scaffold drawings indicate scaffold on top sws exp1,field condition sf bearing on ground w/truss frames supporting floating frames contrary to pe scaffold drawings creates hazard to workers and publ

    Apr 18, 2024

    Resolve
  • Class - 1

    At the time of inspection active 8 story buildings, approximately 80.5" in height upon request for approved ccd1 requirements from the department of buildings, none was provided on site or in the system. i also

    Apr 10, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    28-103.8 failure to maintain embeded safety installation inspection log book onsite.as noted:at time of inspection on an active jobsite for a proposed 8 story building concrete cast-in-place observed concrete e

    Feb 16, 2024 · Penalty $625

    Resolve
  • Class - 1

    Missing to board on guardrails.as noted:at time of inspection at an active jobsite for a proposed 8 story buildings already at the 7th floorlevel with interior framing structure observed from 7th floor level to

    Feb 16, 2024 · Penalty $5,030

    Resolve
  • Class - 2

    Miscellaneous violations. bc 3309.1-protection of adjoining properties. observed bldg. at adjoining property at exp. #2, less than 20ft awayfrom bldg. under construction, w/ no roof protection, no protection fo

    Jan 10, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Miscellaneous violations. bc 3308.6-horizontal netting-observed proposed 8str bldg. with 7fl poured, 8ft working deck. no horizontal nettingor alternate netting system was provided at exp. #1 in compliance with

    Jan 10, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Observed a needle beam platfom with supported scaffold on top of it, over the adj property at exp#2, with no pipe braces on it as per the dob-aprvd dd. observed walkable temp platforms in elevator shaft at flrs

    Jan 10, 2024

    Resolve
  • Class - 1

    Observed multiple areas at the 7fl with missing guard rails, including at exp#1&3 formwork outrigger ends, and around the stairwell opening, creating a fall hazard for workers.

    Jan 10, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    At time of inspection, observed supported scaffold at exp#1 & 4, over 40ft in height (in use). upon review of department records, i found that no temporary construction equipment permit had been issued for thes

    Jan 10, 2024

    Resolve
  • Class - 2

    Temporary construction equipment or installation on site: expired permit: as noted at time of my inspection observed that no fence posted and on further research of dob record show that permit #q00403092i1 issu

    Sep 7, 2023 · Penalty $625

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by const.operations observed:concrete placement taking place for foundation of structure the concrete truck was parked on top of the sidewalk along 21st st

    Sep 16, 2022 · Penalty $10,000

    Resolve
  • Class - 2

    Failure to perform special inspections and verifications for concrete construction as required by section and table 1704.4.as noted:observedactive concrete placement taking place for foundation of structure.i s

    Sep 16, 2022 · Penalty $2,530

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties per rule.as notedat time of inspection on an active construction site,observed the following immediately hazardous conditions:(1)concrete truck completely bl

    Sep 16, 2022 · Penalty $10,000

    Resolve
  • Class - 1

    At time of inspection the following was observed, upon arrival to site i noticed construction gate exp.1 open and swinging outward to street when gates are to swing inward as per 3307.7.2, creating a hazard for

    Jul 22, 2022 · Penalty $2,530

    Resolve
  • Class - 2

    At time of inspection observed construction operations in progress, upon review of support of excavation drawings, solider piles were not installed @ exposures 3 and 4 as required in accordance to approved plan

    Jun 21, 2022 · Penalty $1,250

    Resolve