roofy

42-38 27th Street

Queens, NY 11101BBL 4-00430-0016Map

Owner of record: Bs Lic Realty LLC

42-38 27th Street is an elevator apartment building built in 2025 in Queens, 11101. It has 56 residential units across 7 floors. The owner of record is Bs Lic Realty LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
0
ECB violations
27
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 0

No DOB violations on record

ECB violations · 27

  • Class - 1

    2 apts. 5a and 5k on the 5th floor were fully furnished model apartments with beds, tables, chairs, couches, stove, tv, computers,. records showed no temporary certificate of occupancy. floor occupied without a

    Sep 30, 2026 · Penalty $2,500

    Active
  • Class - 1

    Active construction site, 2 apts. 5a and 5k on the 5th floor were fully furnished model apartments with beds, tables, chairs, couches, stove, tv, computers,. records showed no temporary certificate of occupan

    Aug 3, 2026 · Penalty $2,530

    Active
  • Class - 2

    Observed 1fl staircase to cellar by exp #1-2 covered with a makeshift platform, made by plywood, a few 2x4 lumbers and shattered pieces. it was serving as a ramp and walkway. unsafe platform could be collapse i

    Jul 16, 2026 · Penalty $2,500

    Active
  • Class - 2

    Observed exp #3 backside on facade phase, supported scaffold with no endrails, loose planks. working materials and tools scattered around before the shift (bc 3314.1). scaffold out of maintenance is a hazard no

    Jul 16, 2026 · Penalty $2,530

    Active
  • Class - 2

    Observed exp #3 excessive garbage and loose items on scaffold, leading edge before the shift. loose and light weight items on rooftop. these things could fall, blew away and struck people. exp #1 mesh wire on f

    Jul 16, 2026 · Penalty $1,280

    Active
  • Class - 1

    At the time of inspection of a 8-story new building, the building exterior at exposure one and 4 was observed to be substantially complete despite a stop work order issued on 05/11/2026 under reference no 4a34

    Jun 22, 2026 · Penalty $12,500

    Resolve
  • Class - 1

    Bc3314.4.8 observed : supported scaffold erected on exposure 1,3 & 4 upon inspection noted: missing toe boards & screw jacks in diferent levels and locations , also noted power lines not protected on exposure 4

    May 11, 2026 · Penalty $5,000

    Resolve
  • Class - 1

    Observed: a great amount of garbage on 1st floor and cellar ,like metal wood and black plastic bags creating fire hazards and rodent infection on site contrary to nyc fire and nyc building code . stop all work

    May 11, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain/display onsite documents required by bc chapter 33. as noted at time of inspection on an active construction site, 7 story new building superstructural completed to bulkhead. observed at ope

    Mar 31, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    Observed housekeeping issues on diferents floors and locations .like wood ,black plastic bags ,pile of dry concrete on floor wood palets , skyrofoam and others debris creating extremetly dangerous & hazardous

    Mar 14, 2026 · Penalty $2,500

    Resolve
Show 17 more ↓
  • Class - 2

    Observed unsafe conditions during street delivery operations. failed to maintain 2 flaggers to ensure pedestrian protection on public walkway as per 3307.4.4. forklift carrying delivery, plywoods and wood acros

    Jan 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection of 7-story nb, observed fire extinguishers not maintained nor readily available as per bc in case of emergency, fire extinguishers not seen on floors 3,4,5. expired fire extinguishers were

    Jan 6, 2026 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection of 7-story nb, observed inadequate dewatering at cellar level. puddles of water all throughout cellar level. noted elevator pits at cellar level w/ excess amounts of standing water. create

    Jan 6, 2026

    Resolve
  • Class - 1

    New 7 story building . observed upon exterior inspection .vertical netting inadequate at 2nd 3rd floor exp 4 creating hazardz for workers on site at time of work and contrary to building code 3308.5 stop all w

    Dec 21, 2025 · Penalty $10,030

    Resolve
  • Class - 2

    New 7 story building upon exterior inspection was noted sws has been instaled on site but light never was rturned on contrary to building code 3307.6.2

    Dec 21, 2025 · Penalty $655

    Resolve
  • Class - 2

    New 7 story building upon exterior inspection was noted fence erected on site with missing panel view exposure 4 and project information panel exp 4

    Dec 21, 2025 · Penalty $1,030

    Resolve
  • Class - 2

    Bc 3301.2 at the time of inspection of a proposed 7-story building, multiple uncapped rebars were observed on the top of the first floor, creating a hazardous condition and posing a danger to workers. provide

    Aug 8, 2025

    Resolve
  • Class - 2

    330.2 at the time of my inspection i observe proposed 7 story building top off first floor with guardrail system in place sidewalk shed in place width power line resting on guardrail system and sidewalk shed op

    Aug 8, 2025

    Resolve
  • Class - 2

    At the time of inspection of a proposed 7-story new building, review of department records revealed that the permit has not been approved. stop all work on the entire job site and obtain the required permit.

    Aug 8, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Summons issued for sidewalk shed does not meet code specifications due to lights underneath sidewalk not in operation. job# 619277, comply to code specifications

    Jul 27, 2025 · Penalty $2,400

    Resolve
  • Class - 1

    During inspection of an active site that was lifting material over the construction fence, i observed that there was no sidewalk shed in place to protect pedestrians, workers and property if the material were t

    Jul 23, 2025 · Penalty $10,000

    Resolve
  • Class - 1

    During inspection of an active site with a telehandler moving material over the construction fence, i asked the operator for his required telehandler license, non was provided. the worker said that he did not h

    Jul 23, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Bc 3307.4 warning signs, personnel, and barriers: during inspection i observed 2 trucks in the roadway and on the sidewalk. the storage work zone area was inadequate trucks were not fully enclosed with barriers

    Jul 23, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    During inspection of an active site performing picking operations over the fence, i requested to see the shed drawings. the shed drawings indicated a shed covering the full length of ex#1, but the shed was miss

    Jul 23, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    @inactive nb site in excavation phase observe job fence in place not to codes-@exp#1(27 st) job fence gates not upright/severely leaning susceptible to overturning+same fence condition@exp#3 (rear of site), @ex

    Nov 29, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    @inactive nb site in excavation phase observe sidewalk shed in place without required parapet panel to code bc 3301.9.2 to provide street address of site, contractor name of site,&statement to specifications bc

    Nov 29, 2024 · Penalty $3,125

    Resolve
  • Non-hazardous

    Failure to post copy of certificate of occupancy as required by law. remedy: obtain copy of certificate of occupancy and post as required by law.

    Jun 16, 1988

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D6)
Year built
2025
Floors
7
Residential units
56
Building area
59,853 ft²
Lot area
13,962 ft²
Zoning
M1-5/R7-3
Community board
402
Council district
26
Block / lot
430 / 16
Assessed value
$1,074,600
Landmark / historic district
No

Questions about 42-38 27th Street

Who owns 42-38 27th Street?

The owner of record in NYC Department of City Planning PLUTO data is Bs Lic Realty LLC.

Does 42-38 27th Street have violations?

NYC HPD has no housing violations on record for this property.

Is 42-38 27th Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 42-38 27th Street built?

City records list 2025 as the year it was built.

How many apartments are in 42-38 27th Street?

It has 56 residential units and 57 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.