Violations at 6602 Avenue U
Brooklyn, NY 11234 · BBL 3-08631-0001 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
15 DOB violations, newest first.
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2021
Dob violation - active - High pressure boiler boiler required
Violation issued - failure to file 2017 internal high pressure boiler inspection
Mar 16, 2020
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 3, 2020
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 3, 2019
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 3, 2019
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - High pressure boiler boiler required
Violation issued for failure to file 2013 annual high pressure boiler inspection
Mar 3, 2015
Dob violation - active - Construction other optional
C-construction other optional
Mar 26, 2013
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 18, 2012
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - active - Construction other optional
C-construction other optional
Jun 16, 2010
Vw-violation work without permit - active - Construction other optional
C-construction other optional
Jul 10, 2000
Dob violation - active - Construction other optional
Work without a permit:erection of an extension at western side of bldg south of keyfood supermarket;extension is occupied by a commercial establishment refered to as bobs shoe repair remedy:obtain a permit or restore premises to prior legal condition
May 10, 1999
Vw-violation work without permit - active - Construction other optional
C-construction other optional
Aug 28, 1997
Vw-violation work without permit - active
ECB violations
14 ECB violations, newest first.
- Class - 3
A8: electrical work without a permit for the removal of branch circuit wiring for fixtures and sign. application for electrical inspection not on file., obtain permit; obtain electrical permit.
Jun 10, 2026 · Penalty $250
Active - Class - 1
Found fulton boiler nb#99246 active with hazardous defects. external chimney defective with stuctural defects and signs of restrictions. boiler cease use. do not operate boiler until all hazardous conditions ar
Oct 3, 2022
Resolve - Class - 2
Work without a permit, at the time of inspection and observed a business accessory sign awning approx 16'x5' installed/ without a permit. (soap factory). remedy: obtain all permit (required).
Feb 25, 2019
Resolve - Class - 2
Failure to maintain bldg in code compliant manner:@time of insp observed an awning approx 16'x5'(fell)from store front facade,aluminum frontfacade & caps are loose and possible collapse,electrical wire exposed
Feb 25, 2019
Resolve - Class - 3
Failure to maintain bldg in code compliant manner.handicap parking space in front of dunkin donuts.handicap parking line are difficult to see. paint worn down.rem:provide handicap spaces as per code.
Apr 1, 2011
Resolve - Class - 2
18b,50, 2 (b254) 50 needs fusable link on fresh air lourver.
Jul 6, 2009 · Penalty $500
Resolve - Hazardous
Failure to maintain exterior bldg wall defects noted: east 66 side of property section of apprx 30' of retaining wall collapsed apprx 42" inheight. remedy: maintain exterior bldg wall.
Mar 13, 2008 · Penalty $2,500
Active - Non-hazardous
34
Sep 22, 2006
Resolve - Non-hazardous
50a/50b/34a/50c fucton vt boiler 10hp nb37243 oil 1979 50a)corrosion and leakage on the feed water in let line to the boiler. 50b)improper arrangement of the blowdown valves installed a screw type valve at the
Jan 8, 2005 · Penalty $180
Resolve - Non-hazardous
8c-9a-9b-49 water heater gas breeching joined into breeching of oil burner at right angle must be installed independently- water column drain reduced and needs 2nd value nipple in blowdown & feedline corroded
Nov 17, 2000 · Penalty $180
Active - Non-hazardous
No equipment use permit. installed air condition unit on roof and in operation: remedy: provide equipment nup permit.
Jul 10, 2000 · Penalty $300
Active - Non-hazardous
Work without a permit. work noted erection of an extension side of building south of key food supermarket. extension is occupied by a commerical establishment reported to as bobs shoe repair. obtain a permit or
May 10, 1999 · Penalty $2,500
Active - Non-hazardous
Work without a permit. work noted: one story frame extension constructed at west side north section approximately 24 feet long, 8 feet wide and 16 feet high.
Aug 28, 1997 · Penalty $500
Active - Non-hazardous
Failure to maintain - defects are: 1 ceiling of 1st floor constructed of sheet rock has cracks & holes towrds rear & center 2 ceiling of cellar compressor rm missing sheetrock 3 partition wall @ stairway to cel
Dec 20, 1990 · Penalty $1,000
Active