Violations at 1440 Paerdegat Avenue N

Brooklyn, NY 11236 · BBL 3-08012-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

14 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active

ECB violations

4 ECB violations, newest first.

  • Class - 2

    Incorrect flue pipe, missing chimney clean out, debris in boiler room, missing discharge piping on domestic relief valves. correct all violating conditions and submit a certificate of correction.

    Jul 7, 2021 · Penalty $625

    Active
  • Class - 1

    Pool heater flue corroded with holes and installed in contaminated space cease use, repair all hazardous conditions immediately and call dob 212 393 2784 to lift cease use order

    Dec 6, 2018 · Penalty $6,250

    Active
  • Class - 2

    King valve leaking-debris in boiler room-both coil+hwh relief valves not piped down-lochinvar hwh on ground floor=safety valve not piped down-wires are exposed-condensate neutralizer is missing-debris in room-h

    Dec 6, 2018 · Penalty $3,125

    Active
  • Non-hazardous

    Use of illegal hardware @ 1st fl level there are 2 exit doors that have illegal hardware. consisting of slide bolts & 1 door also has a deadbolt installed. 1st door is located @ rear of soccer field. the other

    Apr 10, 2008

    Resolve