DOB building violations

25 DOB violations, newest first.

  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 13, 2018

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 19, 2016

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    This pvt replaces pvt 494568

    Dec 5, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 9, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 21, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 21, 2009

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 25, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 19, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 17, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 18, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 13, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    3p7564

    Dec 12, 2001

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 8, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 8, 1996

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 17, 1995

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Apr 7, 1992

    Dob violation - dismissed

ECB violations

The newest 50 of 61 ECB violations. The city keeps the complete history.

  • Class - 2

    Re-issue #35663520z. failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors perbc 1006.1; 27-381. noted: on the fourth floor gymnasium two lights, th

    Mar 12, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    Reissue#35671689y exit door not self closing.noted:observed at the auditorium on the left side,the door on the left is not opening.rem:repair/replace door.

    Apr 9, 2024 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue#35671690l failure to maintain building in code-compliant manner:illumination for exits,exit discharges and public corridors per bc 1006.1;27-381.noted:observed on the fourth floor stairs next to the ste

    Apr 9, 2024 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner:illumination for exits,exit discharges & public corridors per 1006.1; 27-381.noted:at gym at 3rd fl & gym at 4th fl 2 emergency exit lighting found defectiv

    Feb 16, 2023 · Penalty $625

    Resolve
  • Class - 2

    Exit door not self-closing.noted:at auditorium at left side of stage exit #1 exit door jammed & does not open at all.remedy:repair/replace door.

    Feb 16, 2023 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:all exit doors either missing door saddle or rusted.remedy:repair or replace.

    Feb 16, 2023 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:at cellar at fan room plumbing pipe leak at two locations.remedy:make necessary repairs.

    Feb 16, 2023 · Penalty $625

    Resolve
  • Class - 1

    Class 1 item: missing dlm as now required by code. class 2 items: provide designated lobby braille tags. replace worn gibs where needed. inoperative pit light. piston leaking.

    Feb 24, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a

    Mar 22, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    Out of service. upon inspection, the device is found to be out-of-service remedy: restore to service immediately and, notify nycdob the device has been returned to service. e-mail [email protected] so an in

    Mar 22, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.reissued#35316967z dated 2/15/18.noted:at inspection in cellar level foundation walls near receiving access doors with spalling,water damage and flaking.rem

    Feb 6, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Replace worn hoistway door gibs where needed. secure hoistway door gibs where needed. clean pit. seal piston leaks. provide designated lobby braille tags. repair phone

    Jul 24, 2019

    Resolve
  • Class - 2

    Restore service to this device

    Jul 24, 2019

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner.note:at inspection in cellar level foundatin walls near receiving access doors w/spalling,water damage and flaking.rem:repair and/or replace

    Feb 15, 2018

    Resolve
  • Class - 2

    Failure to maintain bldg in code-complaint manner.noted:foundation wall @ ave"p"side @cellar has developed a crack approx 20'l.rem:make necessary repair.

    Oct 6, 2016

    Resolve
  • Class - 2

    27-371(b),reissue#35022862z plexi vision panels installed on doors to rooms:401,402,403,405,415,419,301,305,307,315,319,321,254,261,222,123,122,125 & various other location.rem:provide required glass panels.

    Jul 21, 2014

    Resolve
  • Class - 2

    Desks & chairs store(d) in corridor adjacent to room 409, book cases &boxes stored in corridor adjacent to room 254, combustible props & artstore in exit stair from auditorium at left of stage. also excessive

    Jun 4, 2013

    Resolve
  • Class - 2

    Sec. 27-371(b) plexi-vision panels installed on doors to rooms 401,402,403,405,415,419,301,305,307,315,319,321,254,261,222,123,122,125 and various other locations. remedy: provide required glass panels.

    Jun 4, 2013

    Resolve
  • Class - 2

    Fire stopping displaced at: cellar boiler room ceiling between compressor & exhaust ventilation motor concrete encasing steel beam at ceiling has 2 sections each approx 12" missing exposing steel beam. remedy:

    Jan 13, 2012

    Resolve
  • Class - 2

    Plaster ceiling water damaged/spalling/cracked/bulging at: 4th story gymnasium above entry doors, at: 3rd story gymnasium above center window, at: 1st story cafeteria soffit. remedy: repair defects noted.

    Jan 13, 2012

    Resolve
  • Class - 2

    Doors not closing at: 1st story cafeteria exit to stairs d & f (door jmb split), 2nd story stairs d & e, 3rd story stairs d & e, 4th story room 425 (door jamb split). remedy: repair/replace defects noted.

    Jan 13, 2012

    Resolve
  • Class - 2

    02b10,10h11,10b01,11d06,11x10,15b10,24x10,39o02,41b10,43n10,52b07,40d06,56o02,56y10,61r10,69m07,70o02,71x10,77o02,100m07. 02b- under car. 10b- gap to saddle. 11x- door open, close buttons. 41b- self closing sel

    Aug 12, 2010 · Penalty $500

    Resolve
  • Class - 2

    Water penetration into rooms 401,301,201,454,354, stair i 4th flr, 4 and 2 flr gyms. remedy: seal penetrations.

    Jul 1, 2010

    Resolve
  • Class - 3

    Note: on the 2nd floor, wall mounted emergency lighting fixtures-not working-2ndl-throughout. rem: repair/ replace emergency light.

    Apr 22, 2009 · Penalty $500

    Resolve
  • Class - 3

    Reissue#347123325p, 334712326r note: no f.p.s.c door at electrical meter room, wore mesh transom above is not firestopped. rem: correct fire stopping defects at elec. meter room

    Apr 22, 2009

    Resolve
  • Class - 1

    Reissue: 34560948l exit door totally obstructed with security desk,chair,1 exit door totally obstructed at main entrance. remedy: remove obstruction.

    Oct 2, 2008

    Resolve
  • Class - 2

    Reissue: 34560947j illegal hardware on both access doors to roof/and 1flr stair c key cylinder in place. remedy: remove illegal hardware.

    Oct 2, 2008

    Resolve
  • Class - 2

    Reissue: 34560946h,95k,91z,21x missing fire stopping at electrical meter room above door (wire mesh) & around boiler room walls at top & base of walls/also around spiral stairs at base flr. remedy: provide fire

    Oct 2, 2008

    Resolve
  • Class - 3

    Reissue: 34560945x no self closing hinge/or spring on electrical meter room door. door must self close by itself. remedy: install self closing device.

    Oct 2, 2008

    Resolve
  • Hazardous

    1st fl exit 1 (main exit/entry) door obstructed over 50% by security guard desk. remedy: remove obstruction.

    Feb 7, 2007

    Resolve
  • Hazardous

    Re-issue:34481915j. use of illegal hardware. roof stair buikhead doors"k/j","c" are keyed on stair side, contrary to building code 27-371(j)(i)a3. remedy: remove illegal hardware.

    Feb 7, 2007

    Resolve
  • Hazardous

    Re-issue:34481921x,34508991z,34508992k. failure to provide/maintain fire stopping where required. noted: failure to maintain/provide re- quired fire stopping within cellar boiler room wall penetration along

    Feb 7, 2007

    Resolve
  • Hazardous

    Re-issue:34508990r,34481920y. noted: electrical room door has no closure for door (fpsc). remedy: replace closure (provide fpsc door).

    Feb 7, 2007

    Resolve
  • Non-hazardous

    No fire stopping provided in electrical room above entrance door frame. remedy: provide/maintain fire stopping.

    Mar 28, 2006

    Resolve
  • Non-hazardous

    Reissue #344481921x noted: failure to maintain /provide required fire stopping w/in cellar boiler rm wall- penetration along upper wall areas. & at flr line wall penetrations. remedy: provide/maintain fire stop

    Mar 28, 2006

    Resolve
  • Non-hazardous

    Reissue# 34481920y. noted: not self-closing doors in: (1) electrical rm; (2) elevator machine rm. remedy: repair/replace door/hardware.

    Mar 28, 2006

    Resolve
  • Non-hazardous

    Noted: failure to maintain/provide required fire stopping within cellar boiler room spiral stair exit-wall penetrations along upper wall areas and at floor line wall penetrations. remedy: provide/maintain fires

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: exit doors not self-closing. 1)1st floor auditorium rear middleset,left hand door leaf. 2)electric meter room, 3)elevator machine room 4)gas meter room (raked) remedy:repair/replace door/hardware as requ

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: 1st floor northeast corridor exit doors swings against the flowof egress. remedy:repair/replace doors (correct door swing)

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: exit door required width decreased by obstructions: 1)1st floormiddle exit "j" door not readily openable (reducing exit by 1/3) 2)1stfloor exit 1 (main exit/entry) door obstructed over 50%-security desk,

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: cafeteria place of assembly southeast corner exit doors swings against flow of egress. remedy: make exit doors swing in direction of egress.

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: exit passages/corridors required width by obstructions: 1)roof bulkhead stair "c'-contractor equipment & materials. 2)4th & 3rd floor corridors-desk,chairs,tv & stands and disabled persons accessory equi

    May 11, 2005

    Resolve
  • Non-hazardous

    Noted: use of illegal hardware. 1)roof stair bulkhead doors "k/j" & "c" are keyed on stair side contrary to nyc bldg code 27-371(j)(1)a3. 2)1st floor north east corridor doors inward swinging have turn knobs &

    May 11, 2005

    Resolve
  • Non-hazardous

    Failure to use panic hardware where required by law.note-auditoruim occupancy is 575 and no panic hardware is installed on stage at east side exit door.remedy:provide panic hardware

    Feb 26, 2004

    Resolve
  • Non-hazardous

    Failure to maintain exterior bldg wall.note-water penetrating windows at 3rd and 4th floor (gym)-north side in stairwell # 9 and in gym office # 356 and 456.remedy:repair walls

    Feb 26, 2004

    Resolve
  • Non-hazardous

    Failure to maintain exterior bldg wall.noted:large cracks in bricks above east side windows in 3rd and 4th floor gym.remedy:repair/replace bricks/wall

    Feb 26, 2004

    Resolve
  • Non-hazardous

    Failure to maintain exterior bldg wall.note-broken,loose and missing- cornice at north,south,east and west sides of bldg(shed erected)remedy:repair/or replace cornice

    Feb 26, 2004

    Resolve
  • Non-hazardous

    79,u,16 39, 13,l,11 39,l,11 39 l open 5 close door relays to repair missing mechical lock

    May 31, 2003

    Resolve
  • Non-hazardous

    Failure to use panic hardware where required by law. note: auditorium occupancy #575 and no panic hardware install on stage east side exit door, remedy: provide panic hardware.

    Apr 25, 2003

    Resolve
  • Non-hazardous

    Failure to maintain. defects are: plaster walls in stair case #9, gymnasium offices rooms #356 and 456 are loose, bulging and forming mob. remedy: repai plaster walls

    Apr 25, 2003

    Resolve