  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 9, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 9, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 27, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 30, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 12, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 12, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 18, 2006

    Dob violation - resolved

ECB violations

The newest 50 of 67 ECB violations. The city keeps the complete history.

  • Class - 2

    Reissue#35719927k failure to maintain building wall(s)or appurtenancesnoted:at rooftop and above the chimney and fan room have cracks in thebrick veneer in a staggered/vertical design.rem:repair/replace-fix cra

    Jun 16, 2026 · Penalty $6,250

    Active
  • Class - 2

    Reissue#35719817j failure to maintain building in code-compliant manner.noted:at t.o.i.there were several emergency lights that were not operable when tested.illumination for exits,exit discharges and public co

    Jun 16, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35719819n failure to maintain building in code-compliant manner.noted:there are 2 glass window panels that are cracked in the gym.rem:repair/replace the cracked,broken glass.

    Jun 16, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35719821m failure to maintain building in code-compliant manner.noted:the chain link fence at athletic field in need of serious repairs.the verticle posts are bent way out of plumb,and the base wall is

    Jun 16, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35719822y failure to maintain building in code-compliant manner.noted:concrete ramp at exposure 2 has cracked and failing concrete on the under side above parking spot#53.rem:repair/replace.

    Jun 16, 2026 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted at exp #2, ramp, underside had cracked and spalling area at concrete along horizontal beam which was located directly above parking spot #53. remedy:

    Jul 11, 2025 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted chain link fence and base walls in state of disrepair. at exp #3 athletic field12' tall chain link fence had vertical post bent severly with cross br

    Jul 11, 2025 · Penalty $1,250

    Active
  • Class - 3

    Work without a permit. noted at exp #1 front yard(brighton 4th rd). constructed a wooden deck, size approx 12' x 14' by 5' tall with railings and access ramp. 4 x 4 wood support posts buried in ground, making t

    Jul 11, 2025 · Penalty $250

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. noted two cracked/broken window glass panels inside gymnasium adjacent to north-east facing wall corner. remedy: repair and/or replace.

    Jul 11, 2025 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted at cellarlevel sprinkler room, approx 3'x5'x4' deep pit in ground for drain pipe clear out access was unprotected and missing cover. poses tripping/f

    Jul 11, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner: illumination for exots, exit discharges and public corridors per bc 1006.1; 27-381. noted emergency lights not operative when tested: at 2nd fl corridor by

    Jul 11, 2025 · Penalty $1,250

    Active
  • Class - 2

    Exit door not self-closing. noted exterior doors at exit #14, 5/4, 10,12 and 8 not closing properly when tested. mentioned doors were racked, rubbing on frame on saddle and had defective closure devices. remedy

    Jul 11, 2025 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. noted interior fpsc doors not closing properly at: 3rd fl staircase c and b 2nd fl stair case a, c, e and d, cross corridor smoke doors by rm #214 and inte

    Jul 11, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Reissue #35672931h: work without a permit at 3rd floors level partitions installed from room 342, 328, and 356 to one smaller classrooms. norecords or permit at time of inspection. remedy: obtain permit.

    May 28, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35677336x: failure to maintain building wall(s) or appurtenances: at rooftop level observed at chimney and tans room staggering cracks in vertically lines. remedy: maintain exterior building wall(s).

    May 28, 2025 · Penalty $6,250

    Active
  • Class - 2

    Reissued #35655222k. exit door not self-closing: roof level bulkhead above leading to fans room, excessive rubber on bottom preventing open and closing. remedy: repair/replace exit door.

    Jul 29, 2024 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue #35672930x. failure to maintain building wall(s) or appurtenances. at roof level chimney and fans room crack in wall in vertically and staggered cracks. remedy: maintain exterior wall(s)

    Jul 29, 2024 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35128575l work w/o permit.rm 356, 328 & 342 a&b wall made making 3 rm out of one.remedy:obtain all required permits.

    Apr 3, 2023 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35655220r failure to maintain building walls or appurtenances.roof level chimney & fan rm have cracks in wall.remedy:maintain exterior building wall.

    Apr 3, 2023 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted:observed during inspection of gas meter room,waste line pipe is severely rustedand leaking. water pooling on the floor. remedy: repair and/or replace

    Jun 2, 2022 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. illumination for exits,exit discharges and public corridor per bc 1006.1;27-381. noted:observed during inspection of emergency lights in gym,they were not

    Jun 2, 2022 · Penalty $625

    Resolve
  • Class - 2

    Exit door not self closing. noted: observed during inspection of roof level bulkhead door leading to fan room, not self closing due to excessive rubbing at bottom. remedy: repair and/or replace

    Jun 2, 2022 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: observedduring inspection of boiler room, water pump leaking and water poolingon floor of room. remedy: repair and/or replace

    Jun 2, 2022 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35561184l failure to maintain building wall(s) or appurtenances. noted:observed during inspection of roof level,chimney and fan roomstructure has cracks throughout. remedy: maintain exterior bldg wall

    Jun 2, 2022 · Penalty $3,125

    Active
  • Class - 2

    Reissue:352356698p.failure to maintain bldg wall(s) or appurtenances.noted:chimney and so.east corner has vertical cracks.se corner approx 8ft in length.remedy:comply with code.

    May 19, 2021 · Penalty $3,125

    Active
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a

    Feb 8, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner noted at main entrance interior one of teh front door do not close due to broken door closer repair/replace door

    Apr 22, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain buidling in code compliant manner ilumination for eixts ,exit dicharges and publci corridors per 1006.1;27-381.noted at cafeteria main entrance/exit 6 emergency eixt lighting inoperative whe

    Apr 22, 2020 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35386598x failure to maintain building wall(s) or appurtenances noted at roof level brick chomney has vertical crack approx 8 ft long repair the crack

    Apr 22, 2020 · Penalty $3,125

    Active
  • Class - 2

    Re-issue #35235697n.failure to maintain bld.walls & appurtenances.noted in gymnasium upperwindow glass is cracked.rem:repair and/or replace.

    May 9, 2019

    Resolve
  • Class - 2

    Re-issue #35324785h.failure to maintain bld.walls & appurtenances.noted,at roof level chimney smoke stack has a vertical crack 8' long thro ugh brick.rem:miantain exterior building walls.

    May 9, 2019

    Active
  • Class - 2

    Reissue#35235697n failure to maintain bldg walls or appurtenances. noted: at gym east side glass is cracked in upper(most)section toward ceiling area in the arched window. remedy: repair/replace glass.

    Mar 14, 2018

    Resolve
  • Class - 2

    Reissue#35235698p failure to maintain bldg walls or appurtenances. noted: at roof level chimney smoke stack have vertical crack through the brick masonry approx 8ft long. remedy: make necessary repairs.

    Mar 14, 2018 · Penalty $10,000

    Active
  • Class - 1

    Cease use. 5x10,70o7,17h11,59t7,56y2,19m7,40t7,41d7,13b5,13b10. (70o)sump pump (water in the pit). (17h)1 flr. (59t)provide brake maintenance(perform) & tag the device. (19m)1 flr. (13b)inspect emergency light

    Aug 29, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg wall(s) or appurtenances. noted: @ time of insp observed on the roof level, chimney smoke stack have a vertical crack through the brick masonry @ south-east corner approx 8ft in length.

    Apr 19, 2017

    Active
  • Class - 2

    Re-issue# 35213684r- failure to maintain bldg wall(s) or appurtenances. noted: @ 2nd flr- gymnasium arched windows (2) are cracked on the east side of the gym. on the 1st flr level near main entrance there is a

    Apr 19, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg code compliant manner: lack of emergency lighting for exits,exit discharges & public corridors per bc 1006.1,27. noted: emergency lights not working at gym per check of emergency power,

    Sep 28, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg walls & appurtenances. noted: at exit,at north,at brighton 6th st,paint peeling & cracking,parging above exit doors. remedy: comply w/code./

    Sep 28, 2016

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner. lack of emergency lighting for exits,exit discharges & public corridors per bc 1006.1;27-542. noted: at stairwell a,@ 3rd fl & at rm 341,emergency lites do not

    Sep 28, 2016

    Resolve
  • Class - 3

    Failure to maintain bldg walls & appourtenances. reissue 3518574j reissue nov#35128574j,#350974711y,#35028805r,#34950505x,#34928048z & #34861741n. cracked glass at window at gym(east arch) remedy: comply w/code

    Sep 28, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner lack of emergency power lighting for exits, exit discharges and public corridors per bc 1006.1, 27-542. noted: at stairwell a (3rd fl) and at room 341, emerge

    Sep 20, 2016

    Resolve
  • Class - 2

    Work w/o permit. installed full height partitions. reissue ecb # 35023804p in rooms 356,328 and 342a&b, installed full height partitions. rmdy: comply with nov.

    May 6, 2015

    Active
  • Class - 3

    Failure to maintain bldg wall(s) and or appurtenances: reissue ecb # 35094711y: cracked glass cracked window pane in gym. rmdy: comply w/ nov.

    May 6, 2015

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner: reissue ecb # 35094712x: corridor doors almost all cross corridor doors on every level are not opening/closing properly. rmdy: comply w/nov.

    May 6, 2015

    Resolve
  • Class - 3

    Failure to maintain. note: defective smoke/cross corridor doors & jambs -not opening/closing properly locations: near rm 329 & 229,exit 4/5 2nd floor,rm 184,ramp door leading to basement.

    May 21, 2014

    Resolve
  • Class - 3

    Re-issue # 35023805r. failure to maintain. note: crack in glass window interior side in gym (east arch). remedy: repair defect.

    May 21, 2014

    Resolve
  • Class - 3

    Reissue #34950505x. cracked window. at gym, cracked window panel of east arch upper window. remedy: repair/replace window glazing.

    Jul 2, 2013

    Resolve
  • Class - 2

    Reissue #34928049k divided classroom w/o permit. at 3rd flr, rooms 328-356,342ab non fire proof partitions erected full height creating divided classrooms w/inadequate ventilation, ceiling light fixtures pass

    Jul 2, 2013

    Resolve
  • Class - 2

    Defective concrete. at west ramp, spalling concrete underside of egress ramp w/several cracks and areas missing masonry coating. remedy: repair concrete masonry ramp.

    Jul 1, 2013

    Resolve
  • Class - 2

    Re-issue # 34928049k erected combustible partitions to subdivide classrooms at 3rd story rooms c-34, c-36, & c-32. remedy : obtain permits comply w/ building code

    Mar 21, 2012

    Resolve