2819 West 17 Street
Brooklyn, NY 11224BBL 3-07021-0081Map
Owner of record: 2819 West 17 St LLC
2819 West 17 Street is an elevator apartment building built in 2016 in Brooklyn, 11224. It has 10 residential units across 6 floors. The owner of record is 2819 West 17 St LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 16
- ECB violations
- 46
- HPD complaints
- 0
Available now in this building
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 16
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 20, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 7, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 7, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 7, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 7, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 7, 2018
Dob violation - dismissed - Construction other optional
Stop all work, make safe
Jul 14, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 11, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 11, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 11, 2017
Dob violation - dismissed
Show 6 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 11, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 11, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 29, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 29, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 29, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 29, 2016
Dob violation - dismissed
ECB violations · 46
- Class - 1
Observed 3 workers actively working on a jobsite without sst card - no identification provided for the workers.
Nov 16, 2022
Resolve - Class - 2
At time of inspection on an active jobsite, observed that construction superintendent was not on site and the following conditions took place: failed to designate competent person, missing super's daily log, no
Nov 16, 2022 · Penalty $2,500
Resolve - Class - 2
Observed 3 workers actively working on an active permitted jobsite under nb#320593737. upon request for the super's daily log, approved plans, and daily training log (bc 3321.2.3) identifying each worker and a
Nov 16, 2022 · Penalty $625
Resolve - Class - 2
At the time of inspection i observed a 6 story building under construction.upon research on the bis(building information system)i found the temporary construction equipment(fence)has an expired permit.any tempo
May 11, 2021
Resolve - Class - 1
Failure to safeguard all persons of property affected by construction operations.as noted:at time of inspection at the job site,observed bldgs at the at the 2nd fl apt level and no overhead protection for adjoi
Oct 29, 2020 · Penalty $1,250
Resolve - Class - 2
Temporary construction equipmetn on site expired permit. as noted: at time of my inspetion of a 6 story building under construction observedno fence permit posted on further research permit 320593737 expired
Mar 1, 2019
Resolve - Class - 2
Bc28-105.5.forms filed with department of buildings do not have required signatures-tr1 report.as noted:at time of inspection observed tr1 certificate of complete inspections signed off for helical piles.missin
Dec 12, 2017 · Penalty $800
Resolve - Class - 2
Bc28-105.2.conditions of new building permit.as noted:at time of inspection observed new building permit number:320593737-01-nb filed july 13,2017 line #b is primary structural system as masonry.approved constr
Dec 12, 2017
Resolve - Class - 1
3309.1 sidewalk shed. observed that the sws in place for overhead protection of entrance to ad j property at exp 2 was short by 4 feet and did not cover entire door entrance as required by code.stop all wo
Dec 6, 2017 · Penalty $1,600
Resolve - Class - 1
Design drawings.at time of inspection observed temp wood platforms in elevator shaft.also observed temp wood overhead protection for driveway at exp 4 also wood platform erected on top of elevator shaft,upon
Dec 6, 2017 · Penalty $1,000
Resolve
Show 36 more ↓
- Class - 2
Failure to institute safety measures.workers at leaping edge during masonry ops,on scaffolds and temp wood platforms with no safety measuresin place.for fall protection workrs were wearing harness but were not
Dec 6, 2017
Resolve - Class - 1
3305.2.2 steel field connections.observed home made/fabricated splice plate installed connecting steel columns together at story 1 and 2 u pon request for pe drawing to show connections none were given,as per
Dec 6, 2017 · Penalty $1,600
Resolve - Class - 1
3314.1 supported scaffold does not meet code specification. note: at time of inspection i observed supported scaffold in various locations throughout site. supported scaffold has the following objections. -unse
Dec 5, 2017
Resolve - Class - 2
Inadequate guardrails at elevator shaft. at time of my inspection of a 6 story nb at 3rd floor deck, i observed all 3 floors with inadequate guardrails, the protection of shafts are loose netting, pipe scaffold
Dec 5, 2017 · Penalty $400
Resolve - Class - 1
3314.1 sidewalk shed vertical post not on secure or sound footing. note: at time of inspection i observed vertical post for sidewalk shed displaced from mudsill and ground underneath is undermined. as per code
Dec 5, 2017
Resolve - Class - 1
Bc3309.10 protection of rooves. at time of my inspection of a 6 story nb at 3rd floor deck, i observed brick and cmu being installed above the adj property at expo #2 roof line on 2815 w. 17th street. rem: stop
Dec 5, 2017
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order. noted: scaffold on exp #1 on top of shed that had power line for site touching the scaffold and adjacent property power line closer than 3 feet to
Nov 14, 2017 · Penalty $4,800
Resolve - Class - 2
Project information panel/sidewalk shed parapet panel sign not provide or not to code spec.noted:at time of inspection there is no sign on sidewalk shed parapet at all.rem:comply w/code
Oct 24, 2017
Resolve - Class - 1
Bc3314.1:pswo supported scaffold.1926.451(f)(6)the scaffold shall not be erected,used,dismatled,altered or moved such that they or any material handled on them might come closer to exposed and energized power l
Oct 24, 2017
Resolve - Class - 1
Sec. 3303.4.1 slipping & tripping hazards. at time of inspection observed,job site not active. the job site fence entrance is obstructed by a tripping hazard. an opening was cut into the fence to install a door
Sep 28, 2016 · Penalty $1,600
Resolve - Class - 2
Failure to provide/post signs at job site pursuant to subsection. at time of inspection observed,job site not active. the project information panel provided at site is found to be inadequate & dose not provide
Sep 28, 2016 · Penalty $800
Resolve - Class - 1
Sec. 3307.7.7 condition of fence. at time of inspection observed,job site not active, nails & screws are found to be protruding through the job site fence at exp#1 & 4,putting persons at risk of being injured
Sep 27, 2016 · Penalty $800
Resolve - Class - 2
Sec. 3307.7.8 failure to paint job site fencve hunter green. at time of inspection observed,job site not active. job site fence has not been painted hunter green as required by this section of code. the fence
Sep 27, 2016 · Penalty $800
Resolve - Class - 1
Sec. 3307.7.7 failure to maintain job site fence(condition of fence). at time of inspection observed,job site not active. the job site fence has not been maintained as required & is not a solid construction fen
Sep 27, 2016 · Penalty $800
Resolve - Class - 1
Failure to safeguard public & property. at time of inspection structure at 2nd fl workers working around gas/electric meters of adj property2815 w 17 st. also no overhead protect at front over entrance of 2815
Sep 27, 2016 · Penalty $10,000
Resolve - Class - 1
Sec. 3307.7.3 viewing panels. at time of inspection observed,job site not active. the viewing panels for the job site fence are found to be inadequate & is missing plexiglass as required. plexiglass is required
Sep 27, 2016
Resolve - Class - 2
Sec. 3307.7.5 no design drawing for job site fence. at time of inspection observed,job site not active. no design drawing for the job site fence. a design fence drawing will show details on how the job site fen
Sep 27, 2016
Resolve - Class - 1
Work does not conform to approved construction documents &/or amendments. at time of inspection approved drawings do not accurately depict existing conditions. observed electric meters at exp#2 w/conduit & wiri
Aug 8, 2016 · Penalty $1,000
Resolve - Class - 1
Sec. 3301.2 failure to provide overhand protection. at time of inspection observed active job site. overhead protection is not provided for the adjoining property at exp#2. the front entrance & the rear yard is
Jul 16, 2016 · Penalty $400
Resolve - Class - 1
Sec. 2205.6 fabrication,erection & quality control. at time of inspection observed,active jobsite. workers are modifying steel beams on sitecutting & drilling holes. when approved drawing to allow for field
Jul 16, 2016 · Penalty $1,600
Resolve - Class - 2
Failure to safeguard. noted:fence erected at exp.#2 blocking bldg electrical meters.remedy: stop all work & unblock electrical meters.
Apr 7, 2016
Resolve - Class - 1
Failure to adequately supervise work at a construction site. so as to maintain a safe construction site & ensure compliance with chapter 23.the following conditions were observed: 1. work against swo;2. no reb
Apr 7, 2016 · Penalty $1,600
Resolve - Class - 1
Unlawfully continue work while on notice of swo. noticed at time of inspection workers working on at exp. #4 digging & undermining neighborsdriveway. fswo issued by excavation on 4/06/16 complaint # 3553590. re
Apr 7, 2016
Resolve - Class - 2
Job site fence not to code. noticed at exp. #4. job site fence not 8 feet in hight, approx. 6 feet high. remedy: stop all work, construct fence to code.
Apr 7, 2016
Resolve - Class - 1
Failure to safeguard noticed at exp. #4 rebars sticking out of roofingapprox. 4 feet high no rebar caps provided. remedy: stop all work. provide rebar caps.
Apr 7, 2016 · Penalty $2,400
Resolve - Class - 1
Sec. 3309.4 failure preserve & protect adjoining structure affected byexcation operations. observed damage to the adjoining driveway at exp#4 as a result of excavation for new bldg construction. the contractor
Apr 6, 2016
Resolve - Class - 2
Work does not conform to approved construction documents &/or approvedamendments. the installation of the soldier piles & lagging for section of the support of excavation at exp#4 does not conform to the approv
Apr 6, 2016 · Penalty $250
Resolve - Class - 2
Sec. 3309.6 failure to monitor adjoining structures for movement in all direction during excavation related activity that my adversely affect adjoining structures. excavation work for new bldg construction was
Apr 6, 2016
Resolve - Class - 2
Work does not conform to approved construction document. the construction fence was not erected as per the approved plans. the vertical 6x6 post had raker supports were not installed as per plan.
Apr 6, 2016 · Penalty $250
Resolve - Class - 2
Failure to provide approved/accepted plans at the jobsite. plans for the excavation did not show detail for the support of excavation at exp#2. the bottom of the footing of the adjoining bldg at exp#2 was not
Apr 6, 2016
Resolve - Class - 1
Sec. 3303.4.1 maintance. all sites should be free of tripping hazards.noticed at time of inspection demo of house complete sidewalk at exp#1not maintained,damaged & cracked causing tripping hazard.
May 4, 2015 · Penalty $1,600
Resolve - Class - 2
Failed to obtain a temporary construction permit prior to installationat sidewalk shed. note: observed sidewalk shed erected at front of thebldg. no permit for sidewalk shed. remedy: obtain permit for sidewalk
Mar 21, 2015 · Penalty $500
Resolve - Class - 2
Sec. 3307.6.3 pedestrian protection not in compliance w/section. note:observed sidewalk shed erected at front at the bldg. sidewalk shed notextended 5 feet over the property line that does not meet code specifi
Mar 21, 2015 · Penalty $2,400
Resolve - Class - 2
Sec. 3307.6.4.8.1 pedestrian protection not in compliance w/section. note: observed sidewalk shed erected at front of the bldg. sidewalk shed light not provided that does not meet code specification.
Mar 21, 2015 · Penalty $2,400
Resolve - Class - 2
Sign. note: observed sidewalk shed erected at front at the bldg. sidewalk shed information panel not provided that does not meet code specification. remedy: comply w/code.
Mar 21, 2015
Resolve - Class - 1
Sec. 3314.1 partial stop work order for supported scaffold issued pursuant to 28-204.2 & posted at premises scaffold is unsafe conditions. note: observed supported scaffold 25'high erected at exp#2 & #4. 1)work
Mar 21, 2015 · Penalty $1,600
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D3)
- Year built
- 2016
- Floors
- 6
- Residential units
- 10
- Building area
- 10,680 ft²
- Lot area
- 4,157 ft²
- Zoning
- R6
- Community board
- 313
- Council district
- 47
- Block / lot
- 7021 / 81
- Assessed value
- $779,400
- Landmark / historic district
- No
Questions about 2819 West 17 Street
Who owns 2819 West 17 Street?
The owner of record in NYC Department of City Planning PLUTO data is 2819 West 17 St LLC.
Does 2819 West 17 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 2819 West 17 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 2819 West 17 Street built?
City records list 2016 as the year it was built.
How many apartments are in 2819 West 17 Street?
It has 10 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.