roofy

Violations at 346 Avenue P

Brooklyn, NY 11204 · BBL 3-06631-0001 · Back to the property

HPD housing violations

4 HPD violations, newest first.

  • BHazardous

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination all stories at public hall

    Oct 13, 2011

    Open — Nov sent out
  • BHazardous

    Properly repair with similar material the broken or defective 2,3,4,6,8, wood treads and metal bullnose from 1st to 2nd storey at public hall stairs

    Oct 13, 2011

    Open — Nov sent out
  • BHazardous

    Properly repair with similar material the broken or defective 4,6,7,8, wood treads and metal bullnose from 2nd to 3rd storey at public hall stairs

    Oct 13, 2011

    Open — Nov sent out
  • BHazardous

    Properly repair with similar material the broken or defective 1,4,5,6,8,11 wood treads and metal bullnose, 3rd to 4th storey at public hall stairs

    Oct 13, 2011

    Open — Nov sent out

DOB building violations

11 DOB violations, newest first.

  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    May 13, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active

ECB violations

The newest 50 of 85 ECB violations. The city keeps the complete history.

  • Class - 2

    Reissue: 35691640l-occupancy contrary to that allowed by the c of o onbuildings dept. 1st floor east and west on used as classrooms and storage. remedy: comply with code.

    Feb 20, 2026 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: observed on the first floor in the cafeteria four lights, on the

    Feb 26, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Re-issue #35643390l. occupancy contrary to that allowed by c of o or buildings dept records. noted at time of inspection observed on the first floor east and west is being used play area, and teachers loung, th

    Feb 26, 2025 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain bldg in code compliant manner;illumination for exits,exit,discharges & public corridors per bc1006.1;27-381.noted:1 light in the cafeteria,in the gymnasium 1 light,the auditorium 2 lights.al

    May 13, 2022 · Penalty $625

    Resolve
  • Class - 2

    28-118.3.2 re-issue #35558009r occupancy contrary to that allowed by cof o or bldgs dept records.noted:observed on the 1st fl east & west isbeing used as play area & art class for children w/special needs.contr

    May 13, 2022 · Penalty $3,125

    Active
  • Class - 2

    28-301.1 re-issue #35558010y failure to maintain bldg in code compliant manner.noted:at cellar level observed in the paint storage rm there are signs of water penetration through the old coal hatch.remedy:repai

    May 13, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    28-301.1 re-issue #35558011x.failure to maintain bldg in code compliant manner.noted:observed classrooms #503,505,504,508,509,511,558,555,onthe 4th fl 402,413 & 455,all these doors were not closing properly bec

    May 13, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    Work w/o permit.noted:at time of inspection observed at left side of exp #1(front) illuminated sign displayed several events & activities such as upcoming ballgame pta meeting & holidays. no permits on file for

    Apr 29, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    Reissue35495714r doi5/29/20 failure to maintain bldg in codecompliant manner noted:observed classrm doors 5fl rms558,555,511,509,508,505,504,503,501,4th fl rms402,403,413,415,455@3fl 304,335 doors arent closing

    Apr 15, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35495716k doi5/29/20 failure to maintain bldg in codecompliant manner.noted observed foundation wall has become porous allowing waterto penetrate into paint storage rm@s elevation&along n elevation(ave p

    Apr 15, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35495717m doi5/29/20 occupancy contrary to that allowed by c/o or bldgs dept records.noted observed@1fl e&w play areas used as artclass&a class for children.discont illegal use or amend c/o.

    Apr 15, 2021 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain bldg in codecompliant manner:illumination for exits,exit discharges&public corridors per bc100631;27-381.1fl@lunchrm 1place 2lights,1place 1light existing emergency lights arent operational

    Apr 15, 2021 · Penalty $625

    Resolve
  • Class - 2

    Reissue35495713p doi5/29/20 exit door not selfclosing properly@main entrance left 1exit door,gym stairh,2fl staire by rm213,3fl stair by 307&stiarf by 313&5fl staire&by rm513 exit door not selfclosing properly.

    Apr 15, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Occupancy contrary to that allowed by certificate of occupancy or building department records.noted:observed at first floor east and west play areas are being used as an art class and a class for children with

    May 29, 2020 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-comliant manner.noted:observed foundation walls have become porous allowing water to penetrate into paint storage room at south elevation,and along north elevation(avenue p)

    May 29, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner:illumination forexits,exit discharges and public corridors per bc 1006.1;27-381.noted:observed existing emergency lights at near exit of auditorium were not

    May 29, 2020 · Penalty $625

    Resolve
  • Class - 2

    Re-issue#35433690h failure to maintain building in code-compliant manner.noted:observed classroom doors 5th floor rooms 558,555,512,511,509,508,505,504,503,501,4th floor rooms 402,403,413,415,455 3rd floor room

    May 29, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue#35433692l exit door not self-closing noted:observed main entrance left door exit 1 not self closing door excessively rubs on raised saddle.rem:repair/replace door.

    May 29, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Exit door not self closing noted at the cafeteria exterior door s , gymnasium stair h , 2nd floor stair e by room 213, 3rd floor stair by 307 and stair f by 313 and the 5th floor stair e and f by room 513 exit

    Jun 26, 2019 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner noted at the 3rd floor room 311 and teh 5th floor restroom 557 spalling paint in various areas.make neccessary repairs

    Jun 26, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code complaint manner noted the followwing doors are not working properly 304.345.455.503.504 and 509 repair and or replace

    Jun 26, 2019

    Resolve
  • Class - 2

    Reissue #35325604y noted at the cellar boiler room water penetrationat the foundation wall in various areas maintain exterior wall

    Jun 26, 2019

    Resolve
  • Class - 2

    Reissue of nov#35260308p failure to maintain bldg in code compliant manner. noted: at cellar level, boiler room, water penetration at foundation wall exp #1. rmdy: maintain exterior foundation wall

    Mar 30, 2018

    Resolve
  • Class - 2

    Sec. 28-301.1 unlawful display of artwork in corridor greater than 20%per fdny 20.08 code;fc 803.3.2. noted: artwork displayed in corridors throughout the bldg is greater than 20% allowed per code.

    May 9, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. noted: foundation walls @ boiler room have been become porous @ ave p side allowing the water to enter into the boiler room. remedy: maintain exterior wall.

    May 9, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner: lack of emergency lighting for exits,exit discharges & public corridors per bc 1006.1;27-542. noted: emergency lighting @ playroom west,stair e,f,2 emergency

    May 9, 2017

    Resolve
  • Class - 2

    Exit door not self-closing.noted:classroom doors @room 310,401,408 open in the corridor are defective,racked and do not close property due to defective hardware.rem:repair/replace doors.

    Oct 7, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner.no fire stopping as per bc 712.3 re-issue ecb 35094939k in basement boiler room in dahill rd.side there are multiple holes in ceiling.rem:comply with nov

    Jun 24, 2015

    Resolve
  • Class - 2

    Fire stopping. various areas in basement boiler room ceilings have holes & need to be filled in for fire stopping. remedy: provide fire stopping.

    May 21, 2014

    Resolve
  • Class - 2

    Illegal door hardware. -at cafeteria, brass door kicks installed at bottom of exit doors. -at various classrooms doors thru-out bldg, brass door kicks installed on doors used to keep door open. remedy: remove d

    May 21, 2014

    Resolve
  • Class - 2

    Emergency exit lights. at auditorium, emergency exit lights above exit doors are not functioning & do not come on. remedy: repair or replace emergency lights.

    May 21, 2014

    Resolve
  • Class - 2

    Exterior water penetration. -water penetrating from facade into classrooms, possibly from window lintels. -water penetrating from foundation walls into boiler room. remedy: water proof water penetration areas.

    May 21, 2014

    Resolve
  • Class - 2

    Water penetration. the following rooms or areas have water penetrating from facade or foundation walls: 307,303,413 & basement boiler room. remedy: repair water damaged areas.

    May 21, 2014

    Resolve
  • Class - 2

    Defective windows. throughout building in almost every room, windows are defective & will not either close or open properly. remedy: repair or replace windows.

    May 21, 2014

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner (interior). noted: defective springs in window.do not allow windows to stay in place; they fall.all windows affected. rmdy: repair/replace.

    Jul 30, 2013

    Resolve
  • Class - 2

    Failure to maintain bldg wall(s) & appurtenances.noted: water penetrating north and east sections of building, at various points & through foundation walls. re-issue ecb #34953648r. rmdy: maintain weather proo

    Jul 30, 2013

    Resolve
  • Class - 2

    Failure to maintain bldg wall(s) or appurtenances. noted: exterior concrete stair trip hazard - at exit 4, stair nosing cracked & displaced creating trip hazard condition. reissue ecb #34953650x. rmdy:maintain

    Jul 29, 2013

    Resolve
  • Class - 2

    The following exit doors not self closing 1st flr: playroom west,also closer broken. playground east and no door closer; 2nd flr:west & not identified (gymnasium);defective wood door in gym needs replacement.

    Jul 29, 2013

    Resolve
  • Class - 2

    Steel bathroom stall partitions rusted/deteriorated at 1st story girls bathrooms #112 & #105 at 2nd story boys bathroom #254. remedy: repair &/or replace defects noted.

    Apr 10, 2012

    Resolve
  • Class - 2

    Exterior concrete stair trip hazard at: exit 4 concrete stair nosing cracking/chipped/displaced creating tripping hazard (narrow stair tread). remedy: repair defect noted.

    Apr 10, 2012

    Resolve
  • Class - 2

    Loose,cracked,floor mounts fixed auditorium seating at various locations: throughout auditorium defective floor mounts for fixed seating. remedy: repair defects noted.

    Apr 10, 2012

    Resolve
  • Class - 2

    Water penetrating building envelope & foundation wall. at: various locations throughout north & east elevations & thru foundation wall. remedy: repair defects noted maintain weather proof integrity of building.

    Apr 10, 2012

    Resolve
  • Class - 2

    Water damaged plaster walls & ceilings at: 1st story auditorium (stageceiling) 2nd floor room 203 3rd story room 307. remedy: repair defectsnoted.

    Apr 10, 2012

    Resolve
  • Class - 2

    Fail to maintain observed:spalling/cracked plaster walls & ceiling all bulkheads,ceiling rm 513.remedy:maintain bldg.

    Apr 28, 2010

    Resolve
  • Class - 2

    Reissue 34698006j fail to maintain observed:water penetration into boiler room along ave p wall,& @ electric meter room,stair 8 & through coal bunker doors.remedy:maintain building.

    Apr 28, 2010

    Resolve
  • Class - 2

    Reissue 34771052z.observed:defective fpsc doors 5th fl stair d,4th fl stair c, 2 fl stair b, 2 fl womens room opposite stair c.remedy:maintain building.

    Apr 28, 2010

    Resolve
  • Class - 2

    Failure to maintainobserved:cracked concrete walls around window grat es ave "p" side.remedy:maintain building.

    Apr 28, 2010

    Resolve
  • Class - 3

    Defective doors 5 flr stair d, 2 flr stair b, exit vestibule doors 4,5,9. doors stuck & not closing properly. remedy: repair/replace doors.

    May 20, 2009

    Resolve
  • Class - 3

    Failure to maintain bldg wall in that water is being allowed to penetrate through facade above windows in room's 301, 303 & 305 remedy: makenecessary repairs to prevent water from entering

    Sep 10, 2008

    Resolve
  • Class - 3

    Failure to maintain bldg wall or appurtenances in that the floor grating above basement windows in courtyard play area is rusted, bent & pentrading "upward" causing a trip hazard in the play ground. remedy: rep

    Sep 10, 2008

    Resolve