450 87 Street
Brooklyn, NY 11209BBL 3-06050-0028Map
Owner of record: 452 87 LLC
450 87 Street is a public assembly built in 1923 in Brooklyn, 11209. The owner of record is 452 87 LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 75
- ECB violations
- 23
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 75
- Construction other optional
Failure to maintain building in a code compliant manner.at time of ins pection,observed at exp1 and 2 north and east elev,cracked brick facad e,deteriorated mortar joint,spalling brick.at exp2 east elev,missing b ricks and loose coping pieces.at exp4 west elev,spalling brick,deterio rated wood roof of terrace.remedy:repair and/or replace
Apr 22, 2025
Dob violation - active - Construction other optional
Failure to maintain building in a code compliant manner. observed deteriorating masonry including step cracks vertical cracks, missing motar joints/missing brick. at entrance awning has holes and is rusted at roof level observed opening in roof section, boarded up window. all conditions @ exposures. remedy: repair and/or replace
Oct 30, 2024
Dob violation - active - Immediate emergency anythingoptional
Immediately repair the entire sidewalk shed at exposure 1&2 (north and east elevations) as per 1 rcny 103.4
Jul 2, 2024
Dob violation - dismissed - Construction other optional
Failure to maintain building in a code compliant manner.observed deter iorating masonry including step cracks,vertical cracks,missing/open se ction of bricks on all exposures.also observed missing window panels,b roken railing at parapet level on exp1 north elev.remedy:fix and/or re place
Jun 5, 2024
Dob violation - active - Construction other optional
Failure to maintain buidling in code compliant manner.spalled brick wo work and damaged mortar joints on exposure#1&also missing windows on e exposure.#1. remedy:fix and or replace
Jan 18, 2024
Dob violation - active - Construction other optional
Emergency work order due to defective conditions as follwers;damaged mortar joints and spalled brickwork in multiple locations on exposure #1&2 also missing windows on expo.#1 remedy:immed. repair or replace defective conditions under direction of licensed professional
Jan 18, 2024
Dob violation - active - Construction other optional
Failure to maintain building in a code compliant manner.observed spall brick work and damaged mortar joints on exposures 1&2.also missing window on exposure#1 remedy:fix and or replace
Oct 12, 2023
Dob violation - active - Construction other optional
Failure to maintain building in code compliant manner.observed deterio dterioration of facade.stepcracks.crack,damaged masonry column,missing windows spalling.degraded mortar joints and missing bricks.remedy: maintain building:repair and or replace
Jun 12, 2023
Dob violation - active - Construction other optional
Failure to maintain building in code compliant manner:at time of inspection observed unfinished work on the view exposures 1,2 and 4 with multiple defects,cracks,spalling,eroded joints& missing damaged windows. remedy repair and or replace
Mar 14, 2023
Dob violation - active - Construction other optional
Ftm bldg in code compliant manner. observed mortar and brick cracks, spalling brick, missing brick, missing ceiling and damaged plywood existing defective conditons from previous vilations still present on exp1,2 and 4. remedy: comply with code
Jan 11, 2023
Dob violation - active
Show 40 more ↓
- Construction other optional
Ftm building in code compliant manner. at time of inspection observed building facade still has defective hazardous condition on exp 1,2 & 4 these conditions was cited previous dob#05112022ll103rf and to this day no corrected repairs was done. remedy: repair hazardous conditions as per code
Aug 8, 2022
Dob violation - active - Construction other optional
Failure to maintain building in code compliant manner. bldg has defective hazardous conditions on exp 1,2, and 4. at time of inspect hazardous conditions such as loose plywood hanging from top floor window, missing bricks, spalling bricks and mortar joints at several locations. remedy: repair building as per code
May 11, 2022
Dob violation - active - Construction other optional
Add info-job b00394128-i1 facade stablztn issued completion letter on 01/5/22 per dob-feu inspection 10/07/21 & inspector inspection 1/19/22 as build repairs did not conform w/approved design drawings.provide signed &sealed tr-1 inspection reports submitted by 01/31/2022 to [email protected] shallconform to bc1704.1.2.4
Jan 27, 2022
Dob violation - dismissed - Construction other optional
Ftm exterior bldg facade and appurtenances. at exp 1,2 and 4 observed vertical cracks and apalling at masonry walls
Aug 27, 2021
Dob violation - active - Construction other optional
Failure to comply with commissioner's order. owner has not complied with immed cure order. remedy: immed comply with code and commissioner order
Aug 6, 2021
Dob violation - active - Construction other optional
Failure to cpmply with previous commissioner's order #112619cll1002rf as of 8/6/21 owner has not complied with immediate cure order remedy: immed comply with code and commissioners order
Aug 6, 2021
Dob violation - active - Construction other optional
Failure to comply with commissioner's order 313365(060320cllfa01rf) issued on 06/03/2020 as of 08/06/2021 owner has not complied with immediate cure order. remedy: immed comply with code and commissioner's orders
Aug 6, 2021
Dob violation - active - Construction other optional
Failure to comply with commissioner's order #356745 dated 12/11/2020 (vio#121120feu31001pn)requiring owner permnent repr exter walls at all exp's undr prmt start by 5/24/21.as of 7/27/21 there are no work prmts issued-permnent rpr the exter walls.immed comply w/commish ordr#356745 (121120feu31001pn)dated 12/11/20 to perm rpr the exter walls undr prmt
Jul 27, 2021
Dob violation - active - Construction other optional
Ftm building facade and appurtenances. at time of inspection observed a 6 stroy bldg. defect at columns located at the terrace level consist of loose brick and copings. all columns exhibit vertical cracks and cracks at bricks. remedy: maintain building facade. provide safety measures as per 1rcny 103-04
Mar 31, 2021
Dob violation - active - Construction other optional
Commish order/ftm:per ongoing coord w/bldg ownr,ownrs eng'rs & dob,and per ext wall rpt by cmce dated 11/20/2020,exter walls deter&req protct brce/rprs.ownr retn nyspe prep rpr dwgs.subm scope feu for rvw@apprvl temp rpr protct/brce.wrk strt undr prmt 1/11/21.rmve brce lose debris& unsafe ovhd haz.seal crks.instl montr.perm rprs@allexpos u/pmt 5/24/21
Dec 11, 2020
Dob violation - active - Construction other optional
Commish order ftm:crcks in masn@exp1&2 crner near street lvl crcks at masn buttresses@exp2&4 local [email protected]@exp2&3 buttresses miss deter¬ secured to strct.strl stabl facde@all expos in question.ownr subm by 10/26/20 3 qualifed nyspe's perf 100% hands on insp@all expose &m&m of eval.subm eng'r eval rpt identify all unsafe condns by 11/2/20
Oct 22, 2020
Dob violation - dismissed - Construction other optional
Emerg work order:exp1/2 crnr crck'd @1-2flr.exp1 facade pier@5flr near 1/4 crnr crck'd/delamintd frm strct.parapet crck'd &unstbl at exp2/3 & 3/4 crnrs.5fl exter steel columns@exp4 crck'd/lose inadquat bracd.ownr immd retn nyspe&lic contr stabl brce/remve overhead haz@publ+adj prop instl nettng @exp's 1,2,3,4.work under direct&supv pe.file w/in 2days
Aug 14, 2020
Dob violation - dismissed - Construction other optional
Ftm bldg safe condn:exp 1/2 crnr cracked @1-2fls.exp1 façade pier@5fl near 1/4 crnr cracked&delaminated frm strct.parapet cracked&unstbl at exp 2/3 & 3/4 crnrs.facde wrapped arnd 5fl exp4 terrace cracked&inadq bracd/removed.ownr retn nyspe to evalu entire bldg&prepare repr drwgs bldg to be repr'd under permit start by 10/12/20 & complt by 12/18/20
Aug 14, 2020
Dob violation - active - Construction other optional
F.t.m exterior building facade and appurtenances:exposue#1 north elev, top flr display brickcolumn with vertical cracks-ground level stepped crack from grnd up to northeast corner appx.10ft.high-expo#2 east.elev substantial cracks diagonally up approx.20ft.above grade.remedy: maint.exterior facade take safty measure repair damage.per rcny-103-04
Jun 3, 2020
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 26, 2019
Dob violation - dismissed - Construction other optional
Emergency work:masonry brick bldg displays substantial cracks at ground levle abd higher on exp 1 and 2. also brick post on top floor exposure 1 and 4 corner is substantiall cracked presenting hazard to public. remedy;provide sidealj shed by 11-29-19 and netting by 12-6-19 immed extend sidewalk shed addt'l 40 ft to right west directions
Nov 26, 2019
Dob violation - active - Construction other optional
Ftm exterior building facade and appurtenances. observed structural cracks in brick masonry at exp 2, eat elev. and exp 1 north elev alson brick column on top floor exp 4 displays cracks. remedy:maintain exterior building facade. maintain safety measures. make repairs as per 1rcny 103-04
Nov 26, 2019
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 9, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Emergency none
Unoccupied
Feb 18, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 21, 2015
Dob violation - dismissed - Construction other optional
Fm the facade on the right side of the bldg has deteriorated w/loose brick cracking & local brick bulging condition is unsafe for the public & bldg @ 436 87 st.remedy:immed provide overhead protection for the public&bldg @ 436 87 st. protection of overhead protection to have a min width of 15ft. all wrk to be done under permit
Sep 3, 2015
Dob violation - dismissed - Construction other optional
Fm. the facade on the right side of the bldg has deteriorated with loose brick @ 423 87 st. remedy:immed provide overhead protection for the public & bldg @ 423 87th st. protection of overhead protection to have a min width of 15ft extend the full length of 450 87th st all work to be done under permit
Sep 3, 2015
Dob violation - dismissed - Construction other optional
Fm the facade on the left side of the bldg has deteriorated w/loose brick cracking & local brick bulging condition is unsafe for the public & bldg @ 458 87 st.remedy: immed provide overhead protection for the driveway & bldg @ 458 87 st.overhead protection to have a min width of 3ft.all work to be done under permit
Sep 3, 2015
Dob violation - dismissed - Construction other optional
Failure to cerify correction of a violation. failure to comply with a commissioners order:ecb violation#34895736y was served on 2/4/11 for failure to maintain exterior walls or apartments. remedy: immediately comply with the order of the commissioner all work to be done under permit
Sep 3, 2015
Dob violation - dismissed - Construction other optional
Fm the facade on the rear aide of the bldg has deteriorated w/loose brick cracking & local brick bulging condition is unsafe for the public& bldg @ 437 87 st.remedy: immed provide overhead protection for roof of the bldg @ 437 87 st protection overhead to have a min width of 18ft all work to be done under permit
Sep 3, 2015
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed
ECB violations · 23
- Class - 1
Failure to maintain building in a code-compliant manner. as noted: at the time of inspection, i observed on exposure #1 north elevation. non-fisp building: hazardous vertical crack on brick column on the top fl
Sep 17, 2026 · Penalty $2,500
Active - Class - 2
Failure to obtain a temporary construction permit prior to installation. as noted: at the time of inspection respondent did not obtain a temporary construction equipment permit(fence) prior to installation of t
Sep 17, 2026 · Penalty $1,250
Active - Class - 1
Marquis underscience section in state of this repair. underside panel of marquee have different size openings and can collapse over sidewalk that is open to the general public., repair and/replace
Oct 3, 2025 · Penalty $2,500
Resolve - Class - 2
Failure to comply with commissioner's order contained in summons #39111610m issued on 04/13/2024, and failure to file a certificate of correction pursuant to 28.201.1 and 1 rcny 102-01(d)(2). an acceptable cert
Feb 11, 2025 · Penalty $1,250
Active - Class - 2
Pedestrian protection does not meet code specification. note:-observedrusted corrugated sheet metal with holes in them; rotten wooden planksand deteriorating/defective sws parapet panels. remedy: comply to code
Jun 5, 2024 · Penalty $2,400
Active - Class - 2
Noted cracks and bulging bricks at ground floor below height of shed. building has horizontal cracking and spalding bricks throughout., repair and/or replace; repair or fence.
Apr 13, 2024 · Penalty $625
Active - Class - 2
Side walk shed does not meet code specification. observed rust holes in corrugated sheet metal and deteriorating wooden planks. remedy: conform shed to code specifications.
Jan 18, 2024 · Penalty $2,400
Active - Class - 2
Pedestrian protection does not meet code specifications. note: sidewalk shed erected at exp #1 not maintained in a safe manner as required (3307.6.5.1) corrugated metal and plywood wood decking deteriorated and
Sep 20, 2023
Resolve - Class - 2
Observed that the safety netting attached to one of the exterior brick columns at the buildings exp 3/4 is not attached/missing leaving a potentially hazardous conditions for falling debris. secure safety netti
Jul 19, 2022
Resolve - Class - 2
Failure to maintain building walls or appurtenance note at exposure #1&2 multiple cracks throughout entire length of building also missing mortar trhoughout sidewalk shed installed pemrit #320269623 expired 11-
Dec 6, 2019 · Penalty $1,250
Resolve
Show 13 more ↓
- Class - 1
Failure to maintain building wall(s) or appurtenances note:at the corner of exp #1 & exp #2 observed several cracks at exp#2 there is a crack approxmately 1" wide x 3 stories in length defective martor and bulg
Aug 20, 2019 · Penalty $6,250
Resolve - Class - 2
Failure to comply w/the comm's order contained in summons/vio#35407152l issued on 07-04-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. failure to maintain bldg walls or appurtenances. remedy: comply
Aug 20, 2019 · Penalty $1,250
Resolve - Class - 1
Failure to maintain building walls-exterior. noted:at left side,diagonal brick masonry crack approx. 20 foot w/ separation near the left front corner where there is no sidewalk shed. previously noted in nov#353
Jul 4, 2019 · Penalty $3,125
Resolve - Class - 2
Failure to maintain bldg wall or appurtenance: note: at exp#1 retaining wall made of brick bulging out towards public sidewalk,exp#2 has a large vertical crack approx 15ft in length from 1st fl to roof. sidewal
Feb 8, 2019 · Penalty $1,250
Resolve - Class - 1
Failure to maintain building wall(s) or appurtenances. noted:at exposure#1 retaining wall made of bricks bulging outward towards sidewalk. exp#2 has a large vertical crack approx 15' in length. remedy:maintain
Dec 24, 2018 · Penalty $3,125
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. at the time of inspection & observed at exp#1&2. at exp#2 large vertical cracks approx 8' w/gap at 1/4" plus various location w/vertical & horizontal cracks.
Nov 14, 2018 · Penalty $6,250
Resolve - Class - 1
Reissue 35343957z failure to maintain building walls and appurtenances. noted exp 2 step cracking 1" thick by 3 stories high. remedy: maintain exterior building walls
Sep 28, 2018 · Penalty $6,250
Resolve - Class - 1
Failure to maintain bldg wall(s) or appurtenances. noted: @ time of insp observed a stair step crack in the wall @ exp#2. crack is approx 1"x3 stories in length. provide an engineering report for structural sta
Aug 14, 2018 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner: exp#2(left wall from front)has step cracks running approx 2 stories vertically.
Sep 12, 2015 · Penalty $500
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. where as public sidewalk on 87 street/exp#1 is protected by a shed,exp#2 has severe multiple step cracking on a brick facade;defective mortar w/sporadic openings
Jul 29, 2015 · Penalty $1,000
Resolve - Class - 1
Occupancy contrary to that allowed by c of o of building dept records.c.o. #215103 issued 1-11-77 for alt #888/67 states 4th fl is physical culture establishment health club & kitchen. this floor now used as
Sep 24, 2011
Resolve - Class - 1
Failure to maintain bldg in code-compliant manner. illumination for exits. exit discharges and public corridors per bc 1006.1, 27-381 in that there is insufficient lighting in rear stairwell stairs and hallway
Sep 24, 2011
Resolve - Class - 1
Failure to maintain exterior building walls or appurtenances. at time of inspection observed exterior wall defects at exterior brick facade at exposures 1 & 2. at front of building,exposure 1 observed brick on
Feb 4, 2011 · Penalty $2,500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Public assembly (P9)
- Year built
- 1923
- Floors
- 6
- Residential units
- —
- Building area
- 24,779 ft²
- Lot area
- 6,255 ft²
- Zoning
- C8-2
- Community board
- 310
- Council district
- 47
- Block / lot
- 6050 / 28
- Assessed value
- $1,049,400
- Landmark / historic district
- No
Questions about 450 87 Street
Who owns 450 87 Street?
The owner of record in NYC Department of City Planning PLUTO data is 452 87 LLC.
Does 450 87 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 450 87 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 450 87 Street built?
City records list 1923 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.