roofy

1014 Bay Ridge Parkway

Brooklyn, NY 11228BBL 3-05946-0012Map

Owner of record: Lu, Xueying

1014 Bay Ridge Parkway is a two-family home built in 1925 in Brooklyn, 11228. It has 2 residential units across 2.5 floors. The owner of record is Lu, Xueying. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
13
ECB violations
23
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 13

  • Construction other optional

    Special inspector, alberto roman, pe#95364 surrendered all filing privileges, therefore pursuant to ac 28-105.10.2 borough commissioner has ordered swo under application #321794206.

    Sep 11, 2022

    Dob violation - dismissed
  • Construction other optional

    Special inspector, alberto roman, pe#95364 surrendered all filing privileges, therefore pursuant to ac 28-105.10.2 borough commissioner has ordered swo under application #321794206.

    Sep 11, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 19, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 19, 2022

    Dob violation - dismissed
  • Plumbing none

    The borough commissioner intends to revoke all plumbing approvals and permit issued under job #321794206 due to inactive of license master plumber # 1632. stop all plumbing work under above mentioned permit immediately

    Nov 18, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 18, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 18, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 25, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 19, 2020

    Dob violation - dismissed
Show 3 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 26, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 11, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 6, 2019

    Dob violation - dismissed

ECB violations · 23

  • Class - 2

    Bc3314.1 unsafe supported scaffold.at time of inspection of active jobsite observed at exp #2 supported scaffold erected in place aprox 30 ft in height with loose cross bracing(unsecured)and not fully planked m

    Oct 19, 2021

    Resolve
  • Class - 1

    Unsafe storage of material during constructoin or demolition.at time of inspection of active job site observed at 2nd floor(attic level)construction materials being stored within 10 feet from leading edge at ex

    Oct 19, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Bc3314.1 unsafe supported scaffold.at time of inspection of active jobsite observed at attic level supported scaffod aprox 6 ft in height without baseplates screw jack guardrails secured planks inadequate suppo

    Oct 19, 2021

    Resolve
  • Class - 1

    3309.10 failure to provide roof protection.at time of inspection of active jobsite observed at exp #4 adjacent building no roof protection adjacent building aprox 10 ft in height and construction site aprox 30

    Oct 19, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply w/commissioner's order contained in summons/v39041519k issued5/21/21 &to file c/c pursuant to28-201.1&1rcny102-01.work doesnt conform to approved const docs comply w/commissioner's order &/or

    Sep 17, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#39041519k issued on 05/21/21 & to file a cert of correction pursuant to 28-201.1 & 1rcny 102-01. work does not conform to approved construction docu

    Jul 15, 2021 · Penalty $625

    Resolve
  • Class - 1

    Noted: refer to summons# 39041517r issued for partially removing the pipe scaffolding at exposure 1 (front of building) while on a partial stop work order under complaint# 3722915. at time of inspection, observ

    Jul 15, 2021

    Resolve
  • Class - 2

    Job site fence not constructed or maintained pursuant to subsection.at time of inspection observed viewing panel at exp #1 missing plexiglass or equivalent-protruding scrwe at exp #2-panels at exp #4 not painte

    Jul 13, 2021

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or aproved ammendments. at time of inspection, observed 'salt box' style roof erected where approved drawings call for gable roof, changing framing a

    May 21, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Unlawfully continued work while on notice of a stop work order. observed pipe scaffold partially removed from exp 1 after pswo issued 9/24/19 specifically says 'pswo for scaffold do not use scaffold. do not rem

    May 21, 2021 · Penalty $5,000

    Resolve
Show 13 more ↓
  • Class - 2

    Failure to comply with the commissioner's order contained in summons/violations#35498328m issued on 9/3/2020 and to file a certificate of correction purusant to 28-201.1 and 1rcny 102.01.for:see 3301.2;27-1009a

    Dec 2, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Sec. 3301.2;27-1009(a)failure to safeguard. noted: at time of inspection,observed the scaffolding erected at the left side of the bldg(exp#2)& at the 2nd fl.front(exp#1)has been built around & through the utili

    Sep 3, 2020 · Penalty $12,500

    Resolve
  • Class - 1

    Sec. 3301.2 & 27-1009(a) failure to safeguard. at time of inspection observed scaffolding erected at front & left side(exp#1&2)around & thrupower lines from overhead utilities. no insulation on power lines & th

    Jan 25, 2020 · Penalty $12,500

    Resolve
  • Class - 1

    27miscac28miscbcmi noted at time of inspection i observed at exposure #2 a scaffolding has been erected around overhead power lines without insulation covering or protectiion power lines are currently resting

    Nov 18, 2019 · Penalty $12,500

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#39009699r issued on 09-18-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. unlawfully continued work while on notice of a stop work order.

    Oct 30, 2019 · Penalty $3,125

    Resolve
  • Class - 1

    At time of inspection, scaffolding has been erected around overhead power lines without insulation covering or protection. power lines are currently resting on metal piping of scaffolding creating a hazardous s

    Sep 24, 2019 · Penalty $6,250

    Resolve
  • Class - 1

    At time of inspection, two male workers, installing temporary electrical lighting at cellar and wood framing at 2nd floor, contrary to full stop work order #3713157, comply with stop work order

    Sep 18, 2019 · Penalty $12,500

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guardrails. at time of inspection observed men at work at attic level,no temporary stairs was built for workers to safety ent

    Jul 30, 2019

    Resolve
  • Class - 2

    Failure to provide approved/accepted plans at jobsite at time of inspection. provided plans had numerous missing pages was unable to identify if the work conform w/plans or if he work done on cellar,attic & 1,2

    Jul 30, 2019

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements. attime of inspection observed accessive debris & combustible material at exp#1 of premises. remedy: maintain housekeeping per section requirem

    Jul 30, 2019

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35314632h issued on 11-15-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. failure to safeguard all persons & property affected by constru

    Mar 1, 2019 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to comply with the commissioners order contained in summons/violation#35314632h issued on 11/15/18 and to filea certificate of correctio pursuant to 28-201.1 and 1rcny 102-01.failure to safeguard all pe

    Jan 8, 2019 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by construction operations. noted: at time of inspection, the stairs between cellar level and 1st fl & 1st fl and 2nd fl without guardrails creating hazard

    Nov 15, 2018 · Penalty $12,500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Two-family home (B3)
Year built
1925
Floors
2.5
Residential units
2
Building area
1,603 ft²
Lot area
1,800 ft²
Zoning
R4-1
Community board
310
Council district
38
Block / lot
5946 / 12
Assessed value
$75,780
Landmark / historic district
No

Questions about 1014 Bay Ridge Parkway

Who owns 1014 Bay Ridge Parkway?

The owner of record in NYC Department of City Planning PLUTO data is Lu, Xueying.

Does 1014 Bay Ridge Parkway have violations?

NYC HPD has no housing violations on record for this property.

Is 1014 Bay Ridge Parkway rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1014 Bay Ridge Parkway built?

City records list 1925 as the year it was built.

How many apartments are in 1014 Bay Ridge Parkway?

It has 2 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.