Violations at BBL 3-05835-0001
Brooklyn, NY 11220 · BBL 3-05835-0001 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
33 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 31, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 20, 2017
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 31, 2015
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 22, 2013
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Lblvio-low pressure boiler boiler required
Dec 31, 2009
Dob violation - dismissed - Construction other optional
C-construction other optional
Jul 28, 2009
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed
ECB violations
11 ECB violations, newest first.
- Class - 1
97x17 only elevator in bldg o/o/s uon inspection the device is foundto be out of service creating a hazardous condition as per 14cny 11-02restore to service immediately and notify nycdob the device is returne
Jul 31, 2017 · Penalty $5,000
Resolve - Class - 1
97x0:failure to maintain in code compliant manner,service equipment elevator as per bc 3001.2&27-987.dob records show the only elevator in bldg as active.upon inspection the device is found to be out of service
Jun 20, 2017 · Penalty $10,000
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. lack of emergency lighting for exits, exit discharge and public corridors per (bc1006.1)and (27-542). noted:throughout facility (5) buildings at all levels th
Jun 14, 2017
Active - Class - 1
Failure to safeguard all persons and property.noted: on teh roof(s) ofall 5 buildings, the lighting arrestor system has been dismantled and cut exposing workers to electrical shore condition. in addition,there
Jun 14, 2017
Active - Class - 2
Failure to provide covers face plates. noted: throughout facility 5 buildings there were box covers, through covers missing, exposing livewire.many boxes were in damp/wet locations.rmdy:replace all missing co
Jun 14, 2017
Active - Class - 1
Failure to ground electrical system noted: per articel 250.4 wec & nfpa 780 lighting arrestors, on teh roof of all 5 buildings, the wiring and lighting rods are missing or damaged. the interconnectivity cables
Jun 14, 2017
Active - Class - 1
Unsafe storage of combustible.noted @ time of inspection @ bldg#3,storage of flamable combustibles being stored,storage consist of 35lbs flamable containers,in conjunction w/ 55gal drums w/ waste oil,also conta
Jun 14, 2017 · Penalty $12,000
Active - Class - 2
Failure to maintain bldg in code compliant manner.noted @ time of inspection @ bldg#1,lower level under tool rm,excessive paint peeling fromceiling & (waws),creating a health hazard to workers @ this lower leve
Jun 14, 2017 · Penalty $2,500
Active - Class - 1
Failure to institute/maintain safety equipment measures-no handrails. noted @ time of inspection in bldg#1 @ lower level underneath tool rm,hand rails are missing & pose a fall hazard.rem provide handrails
Jun 14, 2017 · Penalty $5,000
Active - Class - 1
Failure to maintain bldg in code compliant manner. at time of inspection in building 1 i obsered 4" cleanout with a rubber cap (jim cap) cover on mid-level below tool room on waste pipe. also on mid-level next
Jun 14, 2017
Active - Class - 1
97x17 elevator was found out of service. rmdy: restore to service and notify nycdob.
Jun 2, 2017
Resolve