roofy

6418 8 Avenue

Brooklyn, NY 11220BBL 3-05821-0043Map

Owner of record: 6418 8th Ave Realty LLC

6418 8 Avenue is an office building built in 2025 in Brooklyn, 11220. The owner of record is 6418 8th Ave Realty LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
2
ECB violations
23
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 2

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 11, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 30, 2024

    Dob violation - dismissed

ECB violations · 23

  • Class - 2

    Responding to an incident where a worker sustained a foot injury while moving a glass panel approximately 9'x 4' and 1.5" thick on the 1st floor, handled manually by 4 workers. the panel slipped and fell onto a

    Apr 21, 2026 · Penalty $5,000

    Resolve
  • Class - 2

    Bc 3303.3. atoi of a 8 story new building at roof, building approximately 7970 square feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert

    Feb 1, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection observed various workers performing multiple tasks on site including carpentry, housekeeping and maintenance of site. request was made to contractor to provided after hours variance permit

    Dec 20, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    A worker fell from mobile pipe scaffold on jobsite of a 8 story nb permit holder job# b00991102-i1-gc, failed to submit report within 3 business days of required 16 items to code 28-103.21 per-28-103.21.1 via

    Oct 8, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Bc 3301.13.11 responding to an incident where worker fell from mobile pipe scaffold approx. 9:50am. further review reveals construction superintendent notify the dob at 3:36 pm, which construction superintenden

    Sep 24, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Responding to an incident where worker fell from mobile pipe scaffold approx. 9:50am. further review reveals gc notify the dob 3:36pm which gc failed to notify the dob immediately of the onsite incident.

    Sep 24, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Bc 3307.4.7at time of my inspection observed inadequate work and storage zone not as per code. observed 8ft solid fence on roadway side not as per code. no wire mesh on and 4ft solid plywood as required as per

    Sep 24, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3301.8.2 use and tampering prohibited. responding to an incident where worker fell from mobile scaffold. gc partial dismantle the equipment prior to the department reviewing the condition of the equipment.

    Sep 24, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    At time of inspection, observed suspended scaffold not installed per bc 3314, with lifelines not parallel/independent and shackle bolts not secured against loosening. failure to comply with bc 3314 creates coll

    Sep 13, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection, observed worker on supported scaffold over 6 ft high on wheels without required guardrail system. per bc 3315.1.5, guardrails are required where unprotected sides/edges exceed 6 ft. failu

    Sep 13, 2025 · Penalty $2,500

    Resolve
Show 13 more ↓
  • Class - 1

    At time of inspection, observed worker on improvised platform spanning two ladders set on stairway with a single unsecured plank used as walkway. contrary to bc 3301.2, failure to provide safe work platform cre

    Sep 13, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection, observed 4 workers at leading edge at exposure 1 with only 2 anchor points provided. contrary to bc 3301.2, inadequate fall protection system created immediate fall hazard with risk of se

    Sep 13, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    No en drawing approved from dob provided on the job site at the time of inspection., maintain/display required documents; please go to https://www1.nyc.gov/site/buildings/codes/energy-conservation-code.page and

    Jul 22, 2025 · Penalty $3,125

    Resolve
  • Class - 1

    Observed work not in conformance with fdny letter of no objection in regards to waver for elevator in readiness. letter of no objection issued with mandatory stipulations that are not followed. no enclosed stai

    Jul 17, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    Violation of b.c 3307.4.7. observed a work zone storage area installed inadequate and contrary to ssp plans. a concrete washout box a hazardous material place in the street, expose to the public. respondent usi

    Jun 7, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    8 story nb. workers in the phase of pouring concrete and stripping operations. observed at the corner of expo#3 #4. missing roof protection for the mechanical a/c units and the sky light for the adjoining prope

    Jun 7, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    Observed construction fence in place contrary to the approved plans . approved drawing show solid fence.

    Apr 25, 2025 · Penalty $3,125

    Resolve
  • Class - 1

    Observed new 8 story building in progress. building is currently at 2nd story deck. upon review of department records, it was observed that no gc permit for construction of 8 story building is issued. structura

    Apr 16, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to provide flag person-bc.3307.5.atoi i observed track delivery blocking sidewalk. no flag person as required by code to stop vehicule traffic and protect pedestrians on sidewalk passing in front of con

    Sep 13, 2024 · Penalty $5,030

    Resolve
  • Class - 2

    Work does not conform to plan. at time of inspection observed ssp indicate fence around construction site. no fence at entire exp #4. stop all works from exp #4. remedy: comply to plan.

    Aug 17, 2024

    Resolve
  • Class - 1

    At time of inspection observed active ongoing pilimas work when ahv penuit states only "material delivery and excavation". stop all after hours work. remedy: obtain permit.

    Aug 17, 2024 · Penalty $2,530

    Resolve
  • Class - 2

    At time of inspection observed during drilling/pile installation operation at exp#3 side dirty water spread under and above construction fence onto adjacent driveway and awning.; bc3301.2, comply with code

    Jul 31, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Sec. 27-1021(c) job site fence not constructed pursuant to subsection(defective fence). note: observed during inspection sections of the construction fence at the subject locaton had collspsed. approx 20ffet al

    Jan 15, 2021

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O6)
Year built
2025
Floors
8
Residential units
—
Building area
64,796 ft²
Lot area
8,000 ft²
Zoning
M1-1
Community board
310
Council district
38
Block / lot
5821 / 43
Assessed value
$243,450
Landmark / historic district
No

Questions about 6418 8 Avenue

Who owns 6418 8 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 6418 8th Ave Realty LLC.

Does 6418 8 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 6418 8 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 6418 8 Avenue built?

City records list 2025 as the year it was built.