6418 8 Avenue
Brooklyn, NY 11220BBL 3-05821-0043Map
Owner of record: 6418 8th Ave Realty LLC
6418 8 Avenue is an office building built in 2025 in Brooklyn, 11220. The owner of record is 6418 8th Ave Realty LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 2
- ECB violations
- 23
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 2
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 11, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 30, 2024
Dob violation - dismissed
ECB violations · 23
- Class - 2
Responding to an incident where a worker sustained a foot injury while moving a glass panel approximately 9'x 4' and 1.5" thick on the 1st floor, handled manually by 4 workers. the panel slipped and fell onto a
Apr 21, 2026 · Penalty $5,000
Resolve - Class - 2
Bc 3303.3. atoi of a 8 story new building at roof, building approximately 7970 square feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert
Feb 1, 2026 · Penalty $2,500
Resolve - Class - 1
At time of inspection observed various workers performing multiple tasks on site including carpentry, housekeeping and maintenance of site. request was made to contractor to provided after hours variance permit
Dec 20, 2025 · Penalty $6,250
Resolve - Class - 1
A worker fell from mobile pipe scaffold on jobsite of a 8 story nb permit holder job# b00991102-i1-gc, failed to submit report within 3 business days of required 16 items to code 28-103.21 per-28-103.21.1 via
Oct 8, 2025 · Penalty $5,000
Resolve - Class - 2
Bc 3301.13.11 responding to an incident where worker fell from mobile pipe scaffold approx. 9:50am. further review reveals construction superintendent notify the dob at 3:36 pm, which construction superintenden
Sep 24, 2025 · Penalty $5,000
Resolve - Class - 1
Responding to an incident where worker fell from mobile pipe scaffold approx. 9:50am. further review reveals gc notify the dob 3:36pm which gc failed to notify the dob immediately of the onsite incident.
Sep 24, 2025 · Penalty $5,000
Resolve - Class - 2
Bc 3307.4.7at time of my inspection observed inadequate work and storage zone not as per code. observed 8ft solid fence on roadway side not as per code. no wire mesh on and 4ft solid plywood as required as per
Sep 24, 2025 · Penalty $2,500
Resolve - Class - 1
Bc 3301.8.2 use and tampering prohibited. responding to an incident where worker fell from mobile scaffold. gc partial dismantle the equipment prior to the department reviewing the condition of the equipment.
Sep 24, 2025 · Penalty $5,000
Resolve - Class - 2
At time of inspection, observed suspended scaffold not installed per bc 3314, with lifelines not parallel/independent and shackle bolts not secured against loosening. failure to comply with bc 3314 creates coll
Sep 13, 2025 · Penalty $2,500
Resolve - Class - 2
At time of inspection, observed worker on supported scaffold over 6 ft high on wheels without required guardrail system. per bc 3315.1.5, guardrails are required where unprotected sides/edges exceed 6 ft. failu
Sep 13, 2025 · Penalty $2,500
Resolve
Show 13 more ↓
- Class - 1
At time of inspection, observed worker on improvised platform spanning two ladders set on stairway with a single unsecured plank used as walkway. contrary to bc 3301.2, failure to provide safe work platform cre
Sep 13, 2025 · Penalty $2,500
Resolve - Class - 1
At time of inspection, observed 4 workers at leading edge at exposure 1 with only 2 anchor points provided. contrary to bc 3301.2, inadequate fall protection system created immediate fall hazard with risk of se
Sep 13, 2025 · Penalty $5,000
Resolve - Class - 2
No en drawing approved from dob provided on the job site at the time of inspection., maintain/display required documents; please go to https://www1.nyc.gov/site/buildings/codes/energy-conservation-code.page and
Jul 22, 2025 · Penalty $3,125
Resolve - Class - 1
Observed work not in conformance with fdny letter of no objection in regards to waver for elevator in readiness. letter of no objection issued with mandatory stipulations that are not followed. no enclosed stai
Jul 17, 2025 · Penalty $6,250
Resolve - Class - 2
Violation of b.c 3307.4.7. observed a work zone storage area installed inadequate and contrary to ssp plans. a concrete washout box a hazardous material place in the street, expose to the public. respondent usi
Jun 7, 2025 · Penalty $5,000
Resolve - Class - 2
8 story nb. workers in the phase of pouring concrete and stripping operations. observed at the corner of expo#3 #4. missing roof protection for the mechanical a/c units and the sky light for the adjoining prope
Jun 7, 2025 · Penalty $6,250
Resolve - Class - 2
Observed construction fence in place contrary to the approved plans . approved drawing show solid fence.
Apr 25, 2025 · Penalty $3,125
Resolve - Class - 1
Observed new 8 story building in progress. building is currently at 2nd story deck. upon review of department records, it was observed that no gc permit for construction of 8 story building is issued. structura
Apr 16, 2025 · Penalty $6,250
Resolve - Class - 1
Failure to provide flag person-bc.3307.5.atoi i observed track delivery blocking sidewalk. no flag person as required by code to stop vehicule traffic and protect pedestrians on sidewalk passing in front of con
Sep 13, 2024 · Penalty $5,030
Resolve - Class - 2
Work does not conform to plan. at time of inspection observed ssp indicate fence around construction site. no fence at entire exp #4. stop all works from exp #4. remedy: comply to plan.
Aug 17, 2024
Resolve - Class - 1
At time of inspection observed active ongoing pilimas work when ahv penuit states only "material delivery and excavation". stop all after hours work. remedy: obtain permit.
Aug 17, 2024 · Penalty $2,530
Resolve - Class - 2
At time of inspection observed during drilling/pile installation operation at exp#3 side dirty water spread under and above construction fence onto adjacent driveway and awning.; bc3301.2, comply with code
Jul 31, 2024 · Penalty $2,500
Resolve - Class - 2
Sec. 27-1021(c) job site fence not constructed pursuant to subsection(defective fence). note: observed during inspection sections of the construction fence at the subject locaton had collspsed. approx 20ffet al
Jan 15, 2021
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O6)
- Year built
- 2025
- Floors
- 8
- Residential units
- —
- Building area
- 64,796 ft²
- Lot area
- 8,000 ft²
- Zoning
- M1-1
- Community board
- 310
- Council district
- 38
- Block / lot
- 5821 / 43
- Assessed value
- $243,450
- Landmark / historic district
- No
Questions about 6418 8 Avenue
Who owns 6418 8 Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 6418 8th Ave Realty LLC.
Does 6418 8 Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 6418 8 Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 6418 8 Avenue built?
City records list 2025 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.