Violations at 871 50 Street
Brooklyn, NY 11220 · BBL 3-05637-7502 · Back to the property
HPD housing violations
5 HPD violations, newest first.
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 26, 2018
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Dec 11, 2017
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 29, 2016
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 20, 2015
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Mar 4, 2015
Closed — Violation dismissed
DOB building violations
9 DOB violations, newest first.
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 25, 2020
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 8, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 29, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 26, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 26, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 30, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 30, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 5, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 20, 2011
Dob violation - resolved
ECB violations
14 ECB violations, newest first.
- Class - 2
Expired cat 5 tag. holes in machine ceiling have compromised fire rating; only one layer of 5/8" sheetrock observed.
Feb 11, 2026 · Penalty $312
Resolve - Class - 1
Failure to maintain upk in code compliant manner. service elevator equipment as per bc3001.2 & 27-987. upon inspection, the only device in the section of the building is found to be out of service, creating a h
Jan 13, 2025 · Penalty $3,125
Resolve - Class - 2
Failure to maintain building in code compliant manner. upon inspection, the device is found to be out of service. remedy: restore to service and contact the dob elevator division at [email protected]
Oct 9, 2024 · Penalty $625
Resolve - Class - 1
Class 1: out of service. upon inspection, the device is found to be out-of-service remedy: restore to service immediately and, notify nycdob the device has been returned to service. e-mail [email protected]
Nov 12, 2021 · Penalty $1,250
Resolve - Class - 1
Device not running was found with the main line in the off position. this device is the only way to get from the street to the lobby. cat one tag expired on 10/20/17.
Mar 25, 2021 · Penalty $3,125
Resolve - Class - 2
Device bouncing at the floor with the door open constantly. device hard start up. device stop abruptly when leveling at the floor
Mar 25, 2021
Resolve - Class - 1
Missing keys to run the device. provide keys to complete the inspection on the device. contact [email protected] for a re -inspection.
Sep 2, 2020 · Penalty $3,125
Resolve - Class - 2
02x10,25m07,48bb15. 02x-car outside communications inoperative; 25m elevator emer fire signage missing all floors; 48bb
Apr 4, 2018 · Penalty $1,562
Resolve - Class - 2
97x10 repair and restore to service.
Apr 4, 2018 · Penalty $1,562
Resolve - Class - 2
02x10,99bb05,40r09. 02x-outside communications inoperative; 99bb cat1; 40r-remove all trash bags from machine room.
Sep 15, 2017 · Penalty $1,250
Resolve - Class - 2
97x10,02x10,99bb05. 97x-repair and restore to service; 02x-outside communications inoperative; 99bb cat1
Sep 15, 2017 · Penalty $1,250
Resolve - Hazardous
Failure to maintain adequate housekeeping note more than 20cuyrds of cardboard lumber and misc construction debris dumped all over front of site of nb no containers remedy: maintain adequate housekeeping
Mar 14, 2008 · Penalty $5,000
Resolve - Hazardous
Failure to provide adequate protection for sidewalks & walkways duringconstruction operation. noted: side walk way of 867 50th st & sidewalkon front of above bldg have cracks. also the walkway of 867 50th st
Mar 13, 2008 · Penalty $5,000
Resolve - Hazardous
Failure to maintain adequate housekeeping: note 8 feet high construction fence unstable, missing section, leaning throughout. at left side of premises fence linear feet leaning & unstable & missing section
Oct 13, 2007 · Penalty $1,000
Resolve