566 Coney Island Avenue

Brooklyn, NY 11218BBL 3-05361-0006Map

Owner of record: Halperts Holdings LLC

566 Coney Island Avenue is a hotel built in 1911 in Brooklyn, 11218. The owner of record is Halperts Holdings LLC. HPD has recorded 44 housing violations here, most recently on May 7, 2026. 1 of the 44 most recent violations are still open.

HPD violations
44
DOB violations
32
ECB violations
20
HPD complaints
82

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation May 7, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 44

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    May 7, 2026

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 19, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 16, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 29, 2023

    Closed — Violation dismissed
  • C

    Remove device preventing door from being self-closing consisting of permanently installed door stopper at north door to stairs at public hall, 3rd story

    Feb 5, 2023

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the 1st room from north located at b-room 3n, 3rd story, 1st b-room from south at west

    Feb 5, 2023 · Apt 3N

    Closed — Violation closed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 8, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 16, 2021

    Closed — Violation dismissed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper.

    Nov 21, 2019

    Closed — Violation closed
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building.

    Nov 21, 2019

    Closed — Violation closed
Show 34 more ↓
  • A

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling.

    Nov 21, 2019

    Closed — Violation closed
  • A

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected

    Nov 21, 2019

    Closed — Violation closed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd.

    Nov 21, 2019

    Closed — Violation closed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system .. at public hall, 1st story

    Nov 21, 2019

    Closed — Violation closed
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box missing at public hall, 1st story

    Nov 21, 2019

    Closed — Violation closed
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor frame missing at public hall, 1st story

    Nov 21, 2019

    Closed — Violation closed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 24, 2018

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Dec 6, 2017

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 23, 2016

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 19, 2015

    Closed — Violation dismissed
  • C

    Provide hot water at all hot water fixtures in the room located at b-room c2, 3rd story, 3rd b-room from south at west

    Apr 21, 2015 · Apt C2

    Closed — Violation closed
  • B

    Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the room located at b-room c2, 3rd story, 3rd b-room from south at west

    Apr 21, 2015 · Apt C2

    Closed — Violation closed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Apr 21, 2015

    Closed — Violation closed
  • C

    Remove the illegal fastening double cylinder key operated lock installed at door vestibule to at public hall, 1st story

    Apr 21, 2015

    Closed — Violation closed
  • B

    Replace with new the broken or defective painted sprinkler head in the bathroom located at apt c2, 3rd story, 3rd apartment from south at west

    Apr 21, 2015 · Apt C2

    Closed — Violation closed
  • B

    Abate the nuisance consisting of bedbugs in the entire apartment located at apt 2, 1st story

    Oct 9, 2010 · Apt 2

    Closed — Violation closed
  • B

    Abate the nuisance consisting of roaches in the entire apartment located at apt 2, 1st story

    Oct 9, 2010 · Apt 2

    Closed — Violation closed
  • B

    D26-19.07 adm code install and maintain sufficient light or lights of at least 40 watts incandescent or equivalent each, to light adequately from sunset to sunrise the rear yard northwest.

    Sep 27, 1989

    Closed — Violation closed
  • B

    D26-10.01 adm code fire escape defective. adjust the dropladder so that it will slide easily in the guide rods rear yard southwest.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-10.01 adm code properly repair with similar material the broken or defective plaster board clg cellar rear & metal clg boiler room rear.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-10.01 adm code properly repair with similar material the broken or defective clg cellar thru out.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-12.03 adm code paint to the satisfaction of this department the exterior window frames and sashes front all sty exterior.

    Sep 27, 1989

    Closed — Violation closed
  • A

    § 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration walls pierced creating passage ways 1st sty bldg 566 to 572.

    Sep 27, 1989

    Closed — Violation closed
  • B

    § 300, 301, 302, m/d law file plans and obtain a certificate of occupancy to legalize the following alteration or restore premises to prior legal condition 3 sty apt used as office.

    Sep 27, 1989

    Closed — Violation closed
  • A

    § 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration celotex clgs 2 and 3 stys pub halls.

    Sep 27, 1989

    Closed — Violation closed
  • A

    § 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration wood paneling and celotex clg installed 1st sty pub hall thru out.

    Sep 27, 1989

    Closed — Violation closed
  • A

    § 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration wood stud partitions cellar thru out bldg 570.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-33.03 adm code post a sign in rooming unit showing maximum lawful occupancy for sleeping purposes all rooms 3rd sty.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-33.03 adm code post a sign in rooming unit showing maximum lawful occupancy for sleeping purposes all rooms 1st sty.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-20.01 adm code provide a peep hole in entrance door of the dwelling unit so located so as to permit a person inside the dwelling to view any person outside entrance door all units 3rd sty.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-20.01 adm code provide a peep hole in entrance door of the dwelling unit so located so as to permit a person inside the dwelling to view any person outside entrance door all units 2nd sty.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-41.15 adm code post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building.

    Sep 27, 1989

    Closed — Violation closed
  • B

    § 300, 301, 302, m/d law file plans and obtain a certificate of occupancy to legalize the following alteration or restore premises to prior legal condition two additional b rooms 1 sty.

    Sep 27, 1989

    Closed — Violation closed
  • A

    D26-10.01 adm code paint metal in accordance with dept. regulation cornice front at roof.

    Sep 27, 1989

    Closed — Violation closed

DOB building violations · 32

  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2018

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2016 inspection/test

    Sep 15, 2017

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2015 inspection/test

    Dec 1, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 20, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 9, 2015

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2014 inspection/test

    Jun 10, 2015

    Dob violation - dismissed
Show 22 more ↓
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 23, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 10, 2012

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 23, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 4, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 18, 2008

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 5, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 30, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 22, 2005

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Elevator elevatorrequired

    3p3575

    Apr 16, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    3p3575

    Apr 11, 2000

    Dob violation - resolved
  • Construction other optional

    Work without a permit. work noted at 1st floor south side of building remedy: obtain permit if feasible or restore to prior legal condition

    Jan 24, 2000

    Vw*-violation - work w/o permit dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1993

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 17, 1990

    Dob violation - resolved
  • Elevator elevatorrequired

    51-provide proper ventilation on elevator -11

    Nov 4, 1988

    Dob violation - resolved

ECB violations · 20

  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. no certificate of correction on file for vio#39180940y as of 9/18/2026., file a certificate

    Sep 18, 2026 · Penalty $1,250

    Active
  • Class - 1

    Observed throughout building, multiple sprinkler heads were obstructed, bathrooms did not have trap wraps under sinks. within the laundry room flex pipe was used on gas dryers exhaust rather then hard piped whi

    Mar 18, 2026 · Penalty $12,500

    Active
  • Class - 2

    Failure to maintain building in code compliant manner, i observed residential gas flex on commercial dryers(8). per fgc411.1 dryers shall be connected using rigid metallic piping and fittings., repair and/or re

    Feb 18, 2020 · Penalty $310

    Resolve
  • Class - 2

    In main electrical room area behind the electrical cabinet has not been fire stopped, front of the electrical cabinet has been boxed out with sheetrock to meet fire rating but rear not done., provide/maintain f

    Feb 18, 2020

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties per code-@time ofinspection, it was observed that multiple workers were performing const related activies throughout the cellar, mult-sty, bldg+rear exp#3.

    Apr 12, 2019 · Penalty $10,000

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendment.noted:on active jobsite under permit #320599848 has at rear of buidling al windows to remain.at time of inspection all windows

    Jan 9, 2019 · Penalty $620

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35333271p issued on 06-27-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. note: no document file for failure to safeguard all person & or

    Dec 10, 2018

    Resolve
  • Class - 2

    Failure to comply with the commissioners order contained in summons/violation #35333271p issued on 06/27/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.note:no document file fo

    Oct 31, 2018

    Resolve
  • Class - 1

    Failure to comply w/commissioner's order contained in summons/violation#35333270n issued on 06/26/18 and to file a certificate of correctionpursuant to 28-201.1 and 1rcny 102-01. for work w/o a permit. rmdy:com

    Sep 18, 2018

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35333271p issued on 06-27-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. no c of c on file. remedy: comply w/comm's order &/or file a c

    Sep 18, 2018

    Resolve
Show 10 more ↓
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35333271p issued on 06-27-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. remedy: comply w/comm's order &/or file a c of c.

    Aug 2, 2018

    Resolve
  • Class - 1

    Work w/o a permit. noted: 3 sty bldg complete gut renovation owner removed all partition walls,plumbing & electrical wiring at all stories. owner also removed all floor covering exposing all floor joists at all

    Jun 27, 2018

    Resolve
  • Class - 1

    Failure to safeguard all persons & property effected by construction operation. noted: 3 sty bldg completely gutted at all stories & all floor covering was removed exposing the floor joists. is a hazard to fdny

    Jun 27, 2018

    Resolve
  • Class - 2

    B254,4a,15,36,40,3a,5a,34a,38,50a. failure to maintain boiler not registered. 50a-piping not supported properly.

    Nov 19, 2012 · Penalty $500

    Active
  • Class - 1

    01x11,10h11,16b10,17h11,35i10,39y02,40y02,41i10,41b10,44y02,52y02,56y10,56o02,60q03,67x11,98bb05,53h14,11l10,45b07.(01x)replace inoperative stop sw cease use call 212-566-5539 dor appointment.(16b)make all self

    Dec 20, 2010 · Penalty $1,000

    Resolve
  • Non-hazardous

    Illegal occupancy , occupancy contrary to that allowed by c of o #70400. illegal occupancy noted : a legal store /light manufactory /2 family . converted into an illegal multidwelling sro units housing approxim

    Jan 24, 2000

    Resolve
  • Non-hazardous

    Work without permit: work noted: at 1st floor south side of bldg a 36" opening installed in bearing wall creating access between 570 and 572coney island ave . creating a dining room for approximately 60 people

    Jan 24, 2000

    Resolve
  • Non-hazardous

    Work without a permit. five(5) steel columns erected in the cellar to support the center beam. remedy: obtain permit and approved design drwgs

    Mar 10, 1993 · Penalty $350

    Resolve
  • Non-hazardous

    03#,17q,50#,(03)provide adequate ventilation in car. (50)installed newmachine without a permit.

    May 13, 1991 · Penalty $215

    Resolve
  • Non-hazardous

    Failure to maintain defect is 3 metal screw jacks erected @ girder in cellar for temporary support.remedy file application to obtain permit to provide permanent columns to support girder

    Feb 28, 1991 · Penalty $230

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Jan 6, 2024 · Apt 67

    Close
  • Heat/hot water

    Entire building

    Feb 3, 2023 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Apr 17, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Apr 4, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Mar 29, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Nov 21, 2019 · Apt 3P

    Close
  • Heat/hot water

    Entire building

    Nov 20, 2019 · Apt 3P

    Close
  • Plumbing

    Water supply

    May 7, 2015 · Apt C2

    Close
  • Plumbing

    Bathtub/shower

    Apr 19, 2015 · Apt C2

    Close
  • Plumbing

    Bathtub/shower

    Apr 19, 2015 · Apt C2

    Close
Show 40 more ↓
  • Heat/hot water

    Apartment only

    Apr 19, 2015 · Apt C2

    Close
  • Plumbing

    Bathtub/shower

    Apr 13, 2015 · Apt C2

    Close
  • Heat/hot water

    Entire building

    Feb 20, 2015 · Apt B1

    Close
  • Nonconst

    Vermin

    Mar 7, 2012 · Apt C9

    Close
  • General

    Doors

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Floor

    Oct 21, 2011 · Apt 2B

    Close
  • Appliance

    Electric/gas range

    Oct 21, 2011 · Apt 2B

    Close
  • Electric

    Wiring

    Oct 21, 2011 · Apt 2B

    Close
  • Electric

    Wiring

    Oct 21, 2011 · Apt 2B

    Close
  • Electric

    Wiring

    Oct 21, 2011 · Apt 2B

    Close
  • Electric

    Wiring

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Windows

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Windows

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Fire-escape

    Oct 21, 2011 · Apt 2B

    Close
  • Nonconst

    Carbon monoxide

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Mailbox

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Stairs

    Oct 21, 2011 · Apt 2B

    Close
  • Plumbing

    Basin/sink

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Floor

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Floor

    Oct 21, 2011 · Apt 2B

    Close
  • Nonconst

    Vermin

    Oct 21, 2011 · Apt 2B

    Close
  • Nonconst

    Vermin

    Oct 21, 2011 · Apt 2B

    Close
  • Nonconst

    Vermin

    Oct 21, 2011 · Apt 2B

    Close
  • Paint/plaster

    Wall

    Oct 21, 2011 · Apt 2B

    Close
  • Paint/plaster

    Wall

    Oct 21, 2011 · Apt 2B

    Close
  • Paint/plaster

    Wall

    Oct 21, 2011 · Apt 2B

    Close
  • Paint/plaster

    Wall

    Oct 21, 2011 · Apt 2B

    Close
  • Nonconst

    Rubbish

    Oct 21, 2011 · Apt 2B

    Close
  • Appliance

    Electric/gas range

    Oct 21, 2011 · Apt 2B

    Close
  • General

    Floor

    Oct 11, 2011 · Apt 2FL

    Close
  • Paint/plaster

    Wall

    Oct 11, 2011 · Apt 2FL

    Close
  • General

    Fire-escape

    Oct 11, 2011 · Apt 2FL

    Close
  • General

    Floor

    Oct 11, 2011 · Apt 2FL

    Close
  • Nonconst

    Smoke detector

    Oct 11, 2011 · Apt 2FL

    Close
  • General

    Mailbox

    Oct 11, 2011 · Apt 2FL

    Close
  • General

    Locks

    Oct 11, 2011 · Apt 2FL

    Close
  • Plumbing

    Basin/sink

    Oct 11, 2011 · Apt 2FL

    Close
  • Nonconst

    Carbon monoxide

    Oct 11, 2011 · Apt 2FL

    Close
  • General

    Floor

    Oct 11, 2011 · Apt 2FL

    Close
  • Nonconst

    Rubbish

    Oct 11, 2011 · Apt 2FL

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (HH)
Year built
1911
Floors
3
Residential units
—
Building area
17,435 ft²
Lot area
6,540 ft²
Zoning
R5
Community board
312
Council district
39
Block / lot
5361 / 6
Assessed value
$1,597,500
Landmark / historic district
No

HPD registration #374171, last renewed Oct 7, 2024.

Questions about 566 Coney Island Avenue

Who owns 566 Coney Island Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Halperts Holdings LLC.

Does 566 Coney Island Avenue have violations?

Yes. NYC HPD has recorded 44 housing violations at this property.

Is 566 Coney Island Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 566 Coney Island Avenue built?

City records list 1911 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.