Violations at 676 Linden Boulevard

Brooklyn, NY 11203 · BBL 3-04673-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

19 DOB violations, newest first.

  • Construction other optional

    Stop all work make site safe contact dob

    Feb 2, 2012

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    May 4, 1999

    Dob violation - dismissed
  • Construction other optional

    Hazardous

    May 4, 1999

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    May 4, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed

ECB violations

The newest 50 of 68 ECB violations. The city keeps the complete history.

  • Class - 2

    Failure to maintain building in code-compliant manner. noted: at (1st fl) stair e glass mesh panel crack. remedy: repair and/or replace.

    Apr 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. lack of emergency lighting for exits, exit discharges and public corridors per bc 1006.1; 27-542. noted: at (1st fl)library not installed/provided emergenc

    Apr 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: at (1st fl) play area/cafeteria emegency lights not working when

    Apr 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: at (roof)bulkheads stair b/c and d/e with horizontal/vertical cracks across walls throughout various areas. remedy: repair and/or replace.

    Apr 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: at (roof)bulkhead stairs b/c and d/e water damage/staining to ceilings/walls with spalling plaster/paint. remedy: repair and/or replace.

    Apr 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Exit door not self-closing. noted: at (5th fl)hallway smoke door near rm 504(4th fl) stair b (1st fl)exit 2, 3, 4, 5 cafeteria doors are in disrepair/not closing when tested. remedy: repair/replace door.

    Apr 14, 2026 · Penalty $625

    Active
  • Class - 2

    Reissue #35672512n. failure to maintain in code-compliant manner: illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: at time of inspection i observed at gym two of the em

    Mar 15, 2024 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:at roof top bulkhead c water penetration damaging the wall and roof.rem:make necessary repair.

    Mar 10, 2023 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:illumination for exits,exit discharges and public corridor per 1006.1;27-381.at gym two emergency exit lighting found in operative when tested.rem:rep

    Mar 10, 2023 · Penalty $625

    Resolve
  • Class - 2

    Exit door not self-closing.noted at 4th floor stair d by rm508,smoke by rm504,2nd floor stair b by rm201,auditorium entrance,smoke by exit 3smoke by exit 5,1st floor smoke by main entrance to the building and e

    May 5, 2022 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.noted at rooms 506,505,306a,304 and 301 the doors are not working properly.remedy:repair and/or replace.

    May 5, 2022 · Penalty $625

    Resolve
  • Class - 2

    Reissue#35578191k.noted at the basement level electrical meter room have hole above the entrance door.remedy:provide/maintain fire stopping.

    May 5, 2022 · Penalty $3,125

    Resolve
  • Class - 1

    Sec. 3307.7.2 design of gates. note: at time of mny inspection of the gate at jobsite fence located at exp#2,i observed that the gate swingsout into an area accessible to the pedestrian sidewalk creating a haza

    Aug 11, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to provide notificatiuon to dob prior to commencement of earthwork. note: at time of my inspection of a demolition site at a 5 sty bldg construction/work in progress,i observed excavation being done ove

    Aug 11, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain dosplay soe approved plans on site. note: at time of my inspection of an active job site construction work in progress. i observed excavation work over 15 feet deep in progress,review of the

    Aug 11, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    3301.13.5 superintendent on file.note visiting site for more than two weeks. note:at time of inspection of excavation site at building construction work in progress upon examination of superintendent's logbook

    Aug 11, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Reissue35452156l failure to maintain bldg in codecompliant manner:noted:@bsmt electrical rm has no [email protected] &/or repair.

    Jun 8, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Reissue35452152y failure to maintain bldg in codecompliant manner:noted@roof lvl bulkhead,2fl stairf,bsmt.electric rm.water penetration to walls,ceilings&fls.comply w/code.

    Jun 8, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35341683l failure to maintain bldg in codecompliant manner:illuminate exit.noted 2fl auditorium emergency lights not working.comply w/code.

    Jun 8, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35022660k failure to maintain in codecompliant manner noted:custodian rm@cellar has spalling concrete exposing ibeam.comply w/code.

    Jun 8, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue #3545213x (09-05-2019) failure to maintain building in code compliant manner 1st fl exit g #1,2,3&4 cafeteria math entrance 2nd floor stair (b)(d)(e) 3rd floors stairs (e)(c)(d) 4th floor stairs (e) (d)

    Jun 1, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue #35452154h (9-5-2019) failureto maintain building in ocde compliant manner manner @ basement custodians storage room concrete.masonry ceiling spalling /fallen exposing beams @ severla location repair an

    Jun 1, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Exit door not self closing noted; at(1st fl) stair g door check is in disrepair/non operational. rem: repair/replace door.

    Sep 5, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner noted: @basementelectric meter room fire stoiing missing/none throughout in various locations.rem: provide/maintain fire stopping.

    Sep 5, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code complaint manner illumination for exits, exit discharges & public corridors per bc 1006.1/ 27-381 noted: @(2nd fl) auditorium (1st fl) gym/cafeteria emergency lights are non

    Sep 5, 2019

    Resolve
  • Class - 2

    Failure to maintain bldg in code complaint manner noted: @basement custodian closet/storage rm & paint room concrete/masonry ceilng spalling/fallen exposing, i beams @both locations.rem: repair and/or replace

    Sep 5, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner noted: @(5th fl)stair d,b, (roof) stair d,e, (4th fl) stair e,d, (3rd fl) stair e,c,d (2nd fl) stair b,d,e, (1st fl) stair g exit 1,2,4, cafeteria & maint

    Sep 5, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code complaint manner noted: @roof lvlbulkhead, 2nd fl stair f, basement electric room watter penetration/damage to walls, celings & floors with cracks throughout in various

    Sep 5, 2019

    Resolve
  • Class - 2

    Noted: at 2nd floor hall, at auditorium, at 1st floor gy, em light notworking when tested. rmdy: comply with code.

    Jun 6, 2018

    Resolve
  • Class - 2

    Noted: at room 509 window leaks onto classrom rmdy: comply with code.

    Jun 6, 2018

    Resolve
  • Class - 2

    Failure to maintain. noted: at roof leak into room 503. rmdy: comply with code.

    Jun 6, 2018

    Resolve
  • Class - 2

    Noted: southside of building, exterior wall (above 2nd floor) w/ spaulding masonry and cracked bricks. rmdy: comply w/code.

    Jun 6, 2018

    Resolve
  • Class - 2

    Reissue #35022660k failure to maintain building in code compliant manner noted: basement storage room, concrete spaudling off i-beam; i beam is exposed. rmdy: comply with code.

    Jun 6, 2018

    Resolve
  • Class - 2

    Reissue#35147663p issue 10-1-15 failure to maintain bldg in code compliant manner. note: at basement level in custodian(parrid)closet concrete ceiling spalling steel oxidise & concrete cracking. remedy: repair

    Jun 20, 2017

    Resolve
  • Class - 2

    Failure to maitain building in code compliant manner, no fire stoppingper bc.712-3,27-345 noted: at electric meter rm, at ceiling and wall, spalling masonry, creating exposure at ceiling and wall. remedy: compl

    Nov 14, 2016

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner. reissue nov#35147663p. noted at cellar/bsmt at stoarge room, i beam exposed by spalling masonry. remedy: comply with code.

    Nov 14, 2016

    Resolve
  • Class - 2

    Re-issue 35107149x failure to maintain bldg code-compliant manner spalling concrete @bsmt,concrete (ceiling) spalling in (custodian) closet & paint rm.rem:comply w/code repair spalling concrete.

    Oct 1, 2015

    Resolve
  • Class - 2

    Re-issue ecb#35022660k spalling concrete @bsmt,concrete ceiling spalling in custodian closet & paintroom.rem:repair spalling concrete.

    Aug 5, 2014

    Resolve
  • Class - 2

    The concrete is spalling off the ibeam located in custodian storage space room at the basement level leaving the ibeam exposed. rmdy: repair and/or replace concrete.

    Jun 17, 2013

    Resolve
  • Class - 2

    Water penetrating roof at 5th sty roof drain. remedy: maintain water proof integrity of roof/roof drain.

    Mar 1, 2012

    Resolve
  • Class - 2

    - doors not closing - at 2nd sty auditorium stage exit door, 3rd sty stair d. remedy: replace doors.

    Mar 1, 2012

    Resolve
  • Class - 2

    Reissue #34779649h exterior concrete pavement in the school yard have multiple trip hazards. remedy: make safe.

    Jul 20, 2010

    Resolve
  • Class - 2

    Illegal hardware roof access doors have key cylinder. remedy: remove cylinder.

    Jul 20, 2010

    Resolve
  • Class - 2

    The plaster is spalling off the wall located in room 209 2nd flr,room 402 & 403 on 4th flr,room 509 on 5th level. remedy: repair/replace plaster on wall.

    May 21, 2009

    Resolve
  • Class - 2

    The concrete is spalling off the ceiling located at ash hoist & oil tank room at cellar level. remedy: repair/replace concrete ceiling.

    May 21, 2009

    Resolve
  • Class - 2

    Exterior concrete pavement in the school yard is cracked with some missing pieces of concrete causing a tripping hazard. remedy: repair/replace concrete school yard.

    May 21, 2009

    Resolve
  • Class - 2

    Plaster is spalling off the wall located @ rood bulkhead "b & c" @ roof level next to the window. repair / replace plaster on the wall

    Oct 10, 2008

    Resolve
  • Hazardous

    Reissue:34513391l. no fire stopping applied above the electrical room for pipe penetration on basement level. remedy: provide fire stopping

    Mar 5, 2007

    Resolve
  • Hazardous

    No fire stops was provided in electrical room (ceiling) remedy: provide/maintain fire stopping.

    Mar 14, 2006

    Resolve
  • Non-hazardous

    Failure to maintain.defects are third floor boys bathroom stall doors are missing.remedy:replace doors

    Apr 12, 2004

    Resolve