Violations at 2830 Pitkin Avenue
Brooklyn, NY 11208 · BBL 3-04237-0013 · Back to the property
HPD housing violations
3 HPD violations, newest first.
- CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 314, 3rd story, 3rd apartment from east at south
May 13, 2026 · Apt 314
Open — Invalid certification - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 314, 3rd story, 3rd apartment from east at south
May 13, 2026 · Apt 314
Open — Invalid certification - CImmediately hazardous
Remove all obstructions from water closet at waste line in the bathroom located at apt 314, 3rd story, 3rd apartment from east at south
May 13, 2026 · Apt 314
Closed — Violation closed
DOB building violations
38 DOB violations, newest first.
- Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2024
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 21, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 21, 2021
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
May 26, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 26, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2009
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 22, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 22, 2008
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 24, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 24, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 24, 2007
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 2, 2007
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 5, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 29, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 29, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 29, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 7, 2003
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 7, 2003
Dob violation - resolved - Elevator elevatorrequired
3p7187
Aug 27, 2002
Dob violation - resolved - Elevator elevatorrequired
3p7186
Aug 27, 2002
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 2001
Dob violation - dismissed - Elevator elevatorrequired
3p7186
Aug 7, 2000
Dob violation - resolved - Elevator elevatorrequired
3p7187
Aug 7, 2000
Dob violation - resolved - Elevator elevatorrequired
3p7185
Aug 7, 2000
Dob violation - resolved - Elevator elevatorrequired
3p7186
Feb 7, 2000
Dob violation - resolved - Elevator elevatorrequired
3p7187
Dec 3, 1998
Dob violation - resolved - Elevator elevatorrequired
3p7185
Dec 3, 1998
Dob violation - resolved - Elevator elevatoroptional
3
Apr 25, 1991
Dob violation - active
ECB violations
14 ECB violations, newest first.
- Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. file application install dlm and perfor
Apr 16, 2020 · Penalty $1,250
Active - Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. file application install dlm and perfor
Apr 16, 2020 · Penalty $1,250
Active - Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a
Feb 11, 2020
Resolve - Class - 2
11h11,70o2. 11m11-replace numbers on car buttons; 70o2-clean pit area.
Aug 27, 2014 · Penalty $2,500
Resolve - Class - 2
#m7,70o02. provide numbers on car buttons; 70o2-clean pit area.
Aug 27, 2014
Resolve - Class - 2
61g11,42g11,48u05,17h11,70m07,70o02,70y13,77u02,10p06,39x10 61,42g-unreadable fuses 48u-current pressure test tag 17h-replace where needed 70m-ladder 70o-clean 77o-clcean build up 70y-piston 10p-secure 39x-lig
Apr 6, 2011
Resolve - Class - 2
61g11,41w06,48u05,42g11,40r09,40o02,34o02,77o02,70o02,70y13,17h11,70m07,77m07,10d06 61,42g-unreadable fuses 41w-secure 48u-current pressure test tag 40ro-clean out m.r. remove not elevator items 34,77o-clean al
Apr 6, 2011
Resolve - Class - 2
39x10.39l10.61g11.42g11.32h11.77q03.77x10.70o02.71x10.39x toc stp sw. 39l inoperative 42061g unreadable fuses 32h worn guide shoes
Feb 11, 2009
Resolve - Class - 1
17j01.72x10. 10.39l10.41m07.68m07.17h11.17d06.10h11.10d06.08v01.70o02.48m05. 17j extremely misaligned & worn on 1st fl 72x pit stop inoperative 39l toc stp sw. 41m sign 68.69m provide log & code data plates 17h
Feb 11, 2009 · Penalty $1,000
Resolve - Non-hazardous
07x10.17h11.33o02. 07x10 car door stays open on "nogging" repair
May 13, 2008
Resolve - Non-hazardous
74#, 74.repack plunger also realign plunge properly to prevent damage to packing call 212 312-8740 for app. to reinpsect elevator.
Apr 29, 1992 · Penalty $150
Active - Hazardous
73#,06#,74#, 73 cease use elv until replace ant-creep leveling device06 replace car door saddle 74 replace rubber coupling under tank and
Jul 31, 1991 · Penalty $500
Active - Non-hazardous
09h;16h;28h;06a;73#;57o;74#; 06.adjust,or replace car door timer re-adjust elevator leveling.74.provide electric eye.
Jul 8, 1991
Resolve - Non-hazardous
16h;37o;74#;73#; 74.file with this dept.for work done on clinderand plunger.73.perform pressure test and full load test on presence of inspector of tthis dept. call 212-312-8740.
Jul 8, 1991 · Penalty $75
Active