Violations at 165 Bristol Street
Brooklyn, NY 11212 · BBL 3-03520-0008 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
40 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2020
Jun 20, 2021
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 16, 2018
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 11, 2017
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 8, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 16, 2010
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 1, 2009
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 1, 2009
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 3, 2008
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 3, 2008
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 29, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 30, 2006
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Oct 1, 2005
Dob violation - dismissed - Elevator elevatorrequired
3p7957
Aug 14, 2002
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 10, 2000
Dob violation - dismissed - Construction other optional
C-construction other optional
Apr 23, 1999
Dob violation - dismissed - Construction other optional
C-construction other optional
Apr 23, 1999
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 20, 1999
Dob violation - dismissed - Elevator elevatorrequired
3p7957
Dec 3, 1998
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - active - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 1996
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Elevator elevatoroptional
1
Jun 28, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed - Elevator elevatoroptional
1
Apr 7, 1992
Dob violation - dismissed - Elevator elevatoroptional
1
Apr 25, 1991
Dob violation - dismissed
ECB violations
The newest 50 of 57 ECB violations. The city keeps the complete history.
- Class - 2
Reissue:35682757k failure to maintain building in code-compliant manner.illumination for exits,exit discharges and public corridors oppositeexit#12 two lights,rm 147 at main entrance.rem:comply with code.
May 27, 2026 · Penalty $3,125
Active - Class - 2
Re-issue #35671910y.failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. noted: opposite exit 12 two lights, exit 12 two lig
Apr 29, 2025 · Penalty $3,125
Active - Class - 2
Exit door not self-closing. noted: third floor exit 9 and 10 none of these doors were opening and closing properly. remedy: repair/replace door.
Apr 29, 2025 · Penalty $625
Resolve - Class - 2
Reissue #. failure to maintain building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. at time of inspection i observed emergency light by room 147
May 17, 2024 · Penalty $1,562
Active - Class - 2
Failure to maintain building in code-compliant manner:illumination for exits,exit discharges & public corridors per bc 1006.1; 27-381.noted:emergency light by rm 147 & by main entrance to building is inoperativ
Apr 5, 2023 · Penalty $625
Active - Class - 2
Failure to maintain building in code-complaint manner.noted:at 3rd fl rm 373, 1st fl cafeteria entrance & rear left,rm 164,smoke by exit 10 & main entrance to building doors not working properly.remedy:repair a
Apr 5, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner,no fire stoppingper bc712.3;27-345.noted at cellar level electrical,gas,and universal waste room all have penetration through the wall above the entrance do
Apr 5, 2023 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted at roof level adjacent to bulkhead stair d,facing the lower roof,there is a section of the fencing that is missing bolts and is loose.remedy:repair an
Apr 5, 2023 · Penalty $625
Resolve - Class - 2
Exit door not self-closing.noted the exterior door at exit#14 is not working properly.remedy:repair/repalce door.
Apr 5, 2023 · Penalty $625
Resolve - Class - 2
Reissue#35643456p noted on 3rd floor corridor by room 308 and 2nd floor by room 232,the doors are not working properly.
Apr 5, 2023 · Penalty $1,562
Resolve - Class - 2
Reissue#35561017y.failure to maintain building in code compliant manner.noted on 3rd floor smoke door by room 308,on 2nd floor smoke door by room 227,on 1sr floor exit vestibule by doors 2,3,4,5 and 10 cafeteri
May 24, 2022 · Penalty $1,562
Resolve - Class - 2
Exit door not selfclosing noted:@1fl exit door check in disrepair/nonoperational when tested.repair/replace door.
Apr 27, 2021 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in codecompliant manner illumination for exits,exit discharges&public corridors per 1006.1 27-381 noted:1fl auditorium,gym&cafeteria emergency/exit sign lights were out/non operational
Apr 27, 2021 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in codecompliant manner noted:@3fl stairsf&g,hallway doors near rm308 1fl exits2,3,4,5,10,cafeteria,stairsf&g doorsin disrepair/racked.repair &/or replace.
Apr 27, 2021 · Penalty $625
Resolve - Class - 2
Failrue to maintain bldg in codecompliant manner noted:@100f bulkheads4&5 water penetration damage w/spalling paint/plaster to walls/ceilings.repair &/or replace.
Apr 27, 2021 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: @ 2nd flr the corridor front of rm#229 has 35% obstructed w/ a large-screen television & table. rem: comply w/ code.
Sep 21, 2016
Resolve - Class - 2
Exit door not self-closing. noted: @ 1st flr rm#117,116,109, @ 2nd flrrm#225,230, exit(i)&(h), @ 3rd flr rm#330,328,305, exit f-4, exit 7, door of corridor next to rm#229, the doors have defective in the hinges
Sep 21, 2016
Resolve - Class - 2
Exit door not self-closing. noted: @ 2nd flr, the door of corridor next to rm#273, & rm#259, rm#167 @ 1st flr, rm#b44,b30 @ basement & gym office, the doors have defective in the hinger & closers. rem: comply w
Sep 21, 2016
Resolve - Class - 2
Sec: 27-371(b). reissue# 35016753z. vision panels noted plexi vision panels installed @ rm#175,171,170,164,162,247,253,347,373 & library. rem: comply w/ the nov.
Sep 21, 2016
Resolve - Class - 2
Ailure to maintain building in code compliant manner: noted: exit signobstructed by flag in the gymnasium. rmdy: comply w/nov.
Sep 28, 2015
Resolve - Class - 2
Ailure to maintain building in code compliant manner: no fire stoppingper bc 712.3, 27-345. noted: in the gas and electric meter rooms ther e are holes that penetrate the walls.inadequate fire stopping.rmdy:com
Sep 28, 2015
Resolve - Class - 3
Reissue#36111967j failure to maintain building in code compliant manner. failure to provide 1/4" thick wired glass vision panel where rquired as per 27-371(b). noted: vision panels not wired glass throughout en
Sep 28, 2015
Resolve - Class - 2
Re-issue # 35016753z. 27-371(b). plexiglass vision panels installed on many f.p.s.c. doors throughout school. remedy: conform to code.
Jul 14, 2014
Resolve - Class - 2
Corridors partially obstructed with combustible material,at 3rd fl exit d & exit b with tables chairs & handicap wheel chairs. remedy: remove obstructions & provide proper corridor widths.
Apr 17, 2013
Resolve - Class - 2
27-371(b) vision panels noted plexi vision panels installed in variousclassroom doors at various locations-175,171,172,170 & thru-out 1st fl247,153,347,373. remedy:conform to code.
Apr 17, 2013
Resolve - Class - 2
Reissue:34927259y. classroom/office ventilation duct is not in operation/defective located @ room 138 & 119b on the 1st floor level. remedy:repair ventilation duct in classroom/office.
Apr 17, 2013
Resolve - Class - 2
Reissue:34941567r. the insulation that insulates the roof duct work is missing & displaced. remedy:repair and/or replace insulation.
Apr 17, 2013
Resolve - Class - 3
Reissue # 34927257k. no fresh air ventilation at: gas meter room. remedy: provide fresh air intake.
Feb 14, 2012
Resolve - Class - 3
Reissue # 34927258m. duct insulation displaced/missing at: roof missing sections of insulation enclosing duct work. remedy: repair defect noted.
Feb 14, 2012
Resolve - Class - 3
Reissue # 34927260l. water penetration through expansion joint damaging ceiling tile at: public corridor & auditorium 1st story. remedy: seal penetration.
Feb 14, 2012
Resolve - Class - 3
Reissue 34863080y. water penetration through expansion joint causing damages to hallway, auditorium ceiling tiles. remedy: seal penetration.
Sep 23, 2011
Resolve - Class - 2
Defective ventilation in rooms 122,138. no windows in place also ventilation not operating at time of inspection. remedy: maintain ventilation.
Sep 23, 2011
Resolve - Class - 3
Failure to maintain duct insulation on roof, missing sections, causingduct to rust. remedy: repair insulation.
Sep 23, 2011
Resolve - Class - 3
Reissue 34777468j. missing f.a.i in gas meter room. remedy: provide f.a.i.
Sep 23, 2011
Resolve - Class - 3
Failure to maintain bldg in code-compliant manner. noted: ceiling (tiles) at 1st flr (hallway, gym, etc) are damaged due to water penetration. remedy: seal ceiling.
Jul 9, 2010
Resolve - Class - 2
Failure to maintain. noted: paved concrete surface (at 111 bristol st entrance) walkways in disrepair w/portions of concrete missing creating tripping hazard.black top paved play area also in disrepair w/uneven
Jul 9, 2010
Resolve - Class - 3
Failure to maintain bldg in code-compliant manner. noted: no ventilation system observed in boiler room. remedy: provide proper ventilation.
Jul 9, 2010
Resolve - Class - 2
Reissue: 34711571x tables chairs office equipment observed in corridoron all flrs. remedy: remove obstructions maintain clear egress.
May 20, 2009
Resolve - Class - 1
Use of illegal door and hardware. from kitchen to street. installed incorridor diamond lathe security door in front of legal egress door (exterior) door swings into bldg contrary to required egress flow and is
May 19, 2009
Resolve - Class - 2
Reissue: 34711572h third flr metal lockers installed in alternating rows but width in corridor still less than 5'6"min. remedy: remove relocate lockers 50 that corridor width is no less than 5'-6" at any point
May 19, 2009
Resolve - Class - 2
Corridor width decrease by obstruction.noted:at 3fl metal lockers installed in corridor narrowing width.remedy:comply with width requirement5' 6" min.
Nov 20, 2008
Resolve - Class - 2
Obstruction in corridor.noted on all floor(tables). remedy:remove tables.
Nov 20, 2008 · Penalty $2,500
Resolve - Non-hazardous
Failure to maintain. defect is rubber padding on concrete surface in play-ground is loose and missing sections at various locations. remedy:repair and/or replace rubber padding.
May 14, 2004
Resolve - Non-hazardous
"reissue." failure to maintain defect is steel fence next to flag poleis broken and sagging. remedy: repair fence.
May 14, 2004
Resolve - Non-hazardous
83x10,47i10. 83-x-replace burned main motor restore to service
Jul 29, 2003
Resolve - Non-hazardous
Failure to maintain defect is broken and sagging steel fence at south side play yard next to flag pole remedy : repair fence
Feb 20, 2003
Resolve - Hazardous
Failure to maintain building. noted defects : exterior play-yard is missing rubber matts and lifting up. (hazardous). remedy: make repairs.
Mar 22, 2002
Resolve - Hazardous
Failure to maintain building noted defects; perimeter wrought iron fence is peeling and paint hipping. (lead paint). broken fence by flag pole. and broken gate. remedy; make repairs.
Mar 22, 2002
Resolve - Non-hazardous
Failure to maintain building. noted defects: several cracks on all walls of gym block walls. remedy: make repairs.
Mar 21, 2002
Resolve - Non-hazardous
Failure to obtain a permit for temporary construction remedy obtain a permit
May 4, 2001
Resolve