1010 Bushwick Avenue
Brooklyn, NY 11221BBL 3-03321-0028Map
Owner of record: 1010 Bushwick Owner LLC
1010 Bushwick Avenue is an elevator apartment building built in 2018 in Brooklyn, 11221. It has 13 residential units across 7 floors. The owner of record is 1010 Bushwick Owner LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 20
- ECB violations
- 44
- HPD complaints
- 4
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 20
- Construction other optional
The borough commissioner has ordered all work stopped under application # 321192712 due to the contractor withdrawal.
Oct 30, 2023
Dob violation - dismissed - Construction other optional
The borough commissioner has ordered all work stopped under application # 321192712 due to the contractor withdrawal.
Oct 30, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 27, 2021
Dob violation - dismissed - Construction other optional
Borough commissioner has ordered all work stopped under application #321192712 on 10/13/21 due to construction superintendent withdrawal
Oct 14, 2021
Dob violation - dismissed - Construction other optional
Borough commissioner has ordered all work stopped under application #321192712 on 10/13/21 due to construction superintendent withdrawal
Oct 14, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 15, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 15, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 15, 2021
Dob violation - dismissed - Immediate emergency anythingoptional
Make all necessary repairs to sidewalk shed at front
Jun 25, 2021
Dob violation - dismissed - Immediate emergency anythingoptional
Immediately remove formwork and debris at 6th floor and above. and repair entire construction fence
Jun 18, 2021
Dob violation - dismissed
Show 10 more ↓
- Construction other optional
Emergency work order due to unsafe formwork at 6th and 7th floors remedy: remove all formwork from the 7th and 6th floor also all decay and rotten plywood to avoid any falling and flying debris, because of time unused. all work must be supervised by nys lic pe perform work immed with daily engineer's reports
Jun 17, 2021
Dob violation - active - Construction other optional
Failure to comply-previous oath summons 35369130x requested submission of approved plans. plans were not code compliant, summons 35408684r requested inspection reports with photos, tr2 compression results and as-built plan with pe design dwgs to remedy non code compliant cond remedy: provide full sp. insp. reports, tr2 comp. resluts
Mar 24, 2021
Dob violation - active - Construction other optional
Stop all work contact the borough commissioner office
Feb 28, 2020
Dob violation - dismissed - Construction other optional
Stop all work, contact borough comm
Feb 28, 2020
Dob violation - dismissed - Construction other optional
Stop all wrk, contact the borough commissioner office
Feb 28, 2020
Dob violation - dismissed - Construction other optional
Stop all work, contact the borough commissioners office
Feb 28, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 27, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 23, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 23, 2019
Dob violation - dismissed - Construction other optional
Stop all work immediately make site safe contact the borough comm. off ice at 718 9802-3685
Dec 13, 2018
Dob violation - dismissed
ECB violations · 44
- Class - 2
Temporary construction equipment on site-expired permit. at the time of inspection at a 7-story new building at 7th floor level; i observed construction fence in place at exposure-#1, upon review of department
Jul 29, 2026
Resolve - Class - 1
At time of inspection observed proposed 7 story nb building currently at 6 floor with no sidewalk shed in place as required by code. stop all exterior work exposure#1 provide sidewalk shed as required.
Dec 29, 2025 · Penalty $4,800
Active - Class - 2
Temporary construction equipment onsite-expired permit.at time of inspection on a closed site,i observed construction fence installed at exp1,2,and 4.after review of dob records,it shows the fence#321192712 iss
Mar 30, 2023 · Penalty $1,250
Resolve - Class - 2
At time of inspection, i observed that the permit holder failed to comply with code as inadequate housekeeping was seen on site at expo #1 front yard and at expo #1 side walk. failure to comply creates a safety
Nov 4, 2022 · Penalty $1,250
Resolve - Class - 2
At time of inspection, i observed that the permit holder failed to comply with code as job site fence was not maintain as graffiti and posting of advertisement was seen painted at expo #1 and not fully painte
Nov 4, 2022 · Penalty $1,000
Resolve - Class - 2
At time of inspection in reference to building code 33307.7.3, i observed the job site fence installed at expo #1 was not in compliance as permit holder failed to provide viewing panels on site fence as require
Nov 4, 2022 · Penalty $1,000
Resolve - Class - 2
At time of inspection on a close site, i observed a temporary construction equipment (fn) installed at the sit`s perimeter. after further review of fn permit on bis which showed the fn permit had expired on 07-
Nov 4, 2022 · Penalty $1,250
Resolve - Class - 2
Const fence not maintained@exp1 atoi i observed that const fence.@exp1wasnt maintained&full of graffiti&postings.this condition violates bldg code3307.7 const fence shall be maintained thruout duration of const
Jun 9, 2022
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/violation#39044995p issued on 7/26/2021 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.for unlawfully continue
Nov 9, 2021 · Penalty $3,125
Resolve - Class - 2
Pedestrian protection does not meet code specifications.at time of inspection it was observed that existing shed sit on adjoining stair 1008bushwick avenue causing water duct to start causing deterioration.reme
Oct 27, 2021 · Penalty $5,000
Resolve
Show 34 more ↓
- Class - 2
Failure to comply w/the comm's order contained in summons/vio#39044995p issued on 07/26/21 & to file a cert of correction pursuant to 28-201.1 & 1rcny 102-01. unlawfully continued work while on a notice of stop
Sep 15, 2021 · Penalty $3,125
Resolve - Class - 2
Temporary construction equipment on site exp permit-sidewalk shed permit expired-obtain permit. note: at the time of my inspeection of a proposed 7 sty new bldg under construction an inactive job site,i oberved
Jul 29, 2021 · Penalty $1,250
Resolve - Class - 2
Pedestrian protection does not meet code specifications. vertical members of sidewalk shed moved 2' towards exp#2,junior beam not supportingtop deck of sidewalk shed,sidewalk closed forcing pedestrians walk int
Jul 29, 2021 · Penalty $2,400
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order. at time of inspection, observed removal of decking in progress by at least 3 workers. this work contrary to partial stop work order issued 6/16/21
Jul 26, 2021 · Penalty $25,000
Active - Class - 1
Bc3303.13-interupted or abandoned and discontinued operations note at the time of my inspection observed unsafe jobsite with no working discontinued activity not maintain jbsite as reuiqred nb permit :321192712
Jun 16, 2021 · Penalty $6,250
Resolve - Class - 2
Temporary equipment onsite permit expired.note:at time of my inspection observed the jobsite construction constructed perimeter of the jobsite with permit expired# 12/25/2020 not renew is required.rem:renew per
Jun 16, 2021 · Penalty $3,125
Resolve - Class - 1
Failure to safeguard all person and property effected by construction note at the time of my inspection observed none actiev jobsite 7 story new building at roof level under construction i observed the jobsite
Jun 16, 2021 · Penalty $12,500
Resolve - Class - 1
Failure to safeguard all public and property affected by construction note at the time o fmy inspection of a 7 story new building at roof level under construction i observed the jobsite gate fence broken and ha
Jun 16, 2021 · Penalty $12,500
Resolve - Class - 2
Temporary construction equipment onsite expired permit-sidewalk shed.note:at time of my inspection observed sidewalk shed installed on pedestrian walkway without maintain and permit expired-03/10/2018 not renew
Jun 16, 2021
Resolve - Class - 2
Temporary equipment on site - expired permit. observed approx. 80 linear ft of construction fence at exposure 1, 2, and 4 erected 8ft in height. permit # 321192712-01-eq-fn expired on 12/25/2020, renew permit
May 6, 2021 · Penalty $3,125
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. observed approx. 16 linear ft. of construction fence at exposure # 2 broken and dismembered falling onto adjacent property 1020 bushwick ave.
May 6, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to safeguard all persons and property affected by construction operations. observed approx. 16 linear ft. of construction fence at exposure # 2 broken and dismembered falling onto adjacent property 1020
May 6, 2021 · Penalty $5,000
Resolve - Class - 2
Observed proposed 7-story stalled nb construction instate of disrepair condition with guardrail netting damaged, hanging and section missing at 2nd to 7th floor all exposures., repair and/or replace
Mar 10, 2021 · Penalty $1,562
Resolve - Class - 2
Observed sidewalk shed permit # 340479823 expired on 03/10/2018 and a violation # 35510486r issued on 12/09/20 for renew the permit. no renewed permit in dob record and sidewalk shed still in place. fence permi
Mar 10, 2021 · Penalty $3,125
Resolve - Class - 2
Permit expired for temp construction equipment (sidewalk shed) onsite note:@time of inspection observed heavy duty sidewalk shed&overhead protection installed @exp1,2,4.also observed in dob system sidewalk shed
Dec 9, 2020 · Penalty $3,125
Resolve - Class - 2
Construction fence.note:@time of inspection observed construction fence erected in inactive jobsite 7stynb.also observed fence door leaning toward roadside (sidewalk side).also broken plywood from fence hanging
Dec 9, 2020 · Penalty $2,500
Resolve - Class - 2
Pedestrians protection doesn't meet code specifications 3307.6.5.3.note:@time of inspection observed hd sidewalk shed&ohp in front of inactive jobsite.pedestrians walking under sws.also observed leaning steel p
Dec 9, 2020 · Penalty $5,000
Resolve - Class - 1
Bc 3301.7 failure to provide p.e design drawings. as noted:at time of inspection of a concrete structure currently at 6th fl level,observed:(a)structural dwg plan view of floor slab shows 10" thick slab,typ. se
Dec 20, 2019 · Penalty $6,250
Resolve - Class - 1
Bc3301.2 failure to provide overhead protection at time of inspection of a 7 story nb currently at 7th story i observed overhead protection for adjacent property at expo#2 inadequate does not protect the adjace
Dec 12, 2019 · Penalty $6,250
Resolve - Class - 1
Failure to safeguard public and propety at time of inspection of a 7 story nb currently public and property by no providing adequate overhead property at exp#2.debris from construction site and damages to adjac
Dec 12, 2019 · Penalty $12,500
Resolve - Class - 1
Bc3308.6.1/failure to provide horizontal safety netting system.at timeof inspection of a 7 story nb currently at 7th story i observed no hr izontal safety netting system installed at exp#1 & 2 as required.6th s
Dec 12, 2019 · Penalty $6,250
Resolve - Class - 1
Bc3309.10/failure to provide adequate roof protection at time of inspection of a 7 story nb currently at 7th story i observed roof protection of adjacent property at exp#2 is inadequate does not extend at least
Dec 12, 2019 · Penalty $6,250
Resolve - Class - 1
Failure to maintain adequate housekeeping at ime of inspection of a 7 story nb currently at 7th story i observe large amount of debris at exp#1(front yard)that pose tripping and fire hazard.stop all work except
Dec 12, 2019 · Penalty $6,250
Resolve - Class - 1
3307.6.5-failure to miantain sidewlak shed as required by code as noted at time of inspection observed a sidewlak erected under permit #b00128340 at a 7 story building the shed erected to protetc the public
Sep 6, 2019 · Penalty $6,250
Resolve - Class - 2
Failure to provide pe approved design drawings. as noted at time of inspection active site 3rd floor level i observed platforms erected atfirst and second floor. no approved pe design drawings available to
Feb 28, 2019 · Penalty $625
Resolve - Class - 1
Material false statement-the respondent-special inspection applicant for job#34058098 submitted a material false statement to the department&signed section 9 of the tr-1 form is required to be signed by the spe
Oct 4, 2018 · Penalty $5,000
Resolve - Class - 1
1rcny 101-06 the respondent failed to perform their duties as special inspection agency. 1rcny101-06 & bc1704.1.2(4.3) states inspector/special agency shall report any conditions noted as hazardous to life,safe
Oct 4, 2018 · Penalty $2,500
Resolve - Class - 2
Sec. 1704.1.1 failure to file a special inspection statement of responsibility prior to permit issuance & prior to start of work under special inspection requirement(no underpining). at time of inspection,i obs
Jun 6, 2018 · Penalty $3,125
Resolve - Class - 2
Failure to perform proper concrete washout proceducer at the construction site,collection & containment. as noted: at time of inspection at an active construction site observed concrete trucks at an active cons
Jun 1, 2018 · Penalty $2,500
Resolve - Class - 2
Work does not conform to approved construction documents &/or amendments. as noted at time of inspection at an active construction observed soe draining & work done did not conform. bracing was missing at expos
Jun 1, 2018
Resolve - Class - 2
Failure to safeguard all persons & property affected by construction operations. as noted: at time of inspection at an active construction site observed slope of the ground more than 45 angle & no guardrail aro
Jun 1, 2018 · Penalty $5,000
Resolve - Class - 2
Job site plywood construction fence not pursuant to subsection as noted: at time of inspection at an active construction site observed at exp#2 & 4 plywood construction site not painted hunter green & need some
Jun 1, 2018
Resolve - Class - 2
3309.6.failure to maintain adjoining structures for movement in all direction during excavation related activity that may adversly affect adjoining structures @ time of inspection i observed excavation activity
Feb 23, 2018
Resolve - Class - 2
Work does not conform to approved construction document and/approved amendments.@ time of inspection i observed activity excavation work on the plans there was 16 steel piles @ exposure 2 in excavation field.th
Feb 23, 2018
Resolve
Complaints
- Unsanitary condition
Mold
Jun 25, 2020 · Apt 1C
Close - Water leak
Damp spot
Jun 25, 2020 · Apt 1C
Close - Paint/plaster
Wall
Jun 25, 2020 · Apt 1C
Close - Unsanitary condition
Sewage
Jun 25, 2020 · Apt 1C
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D7)
- Year built
- 2018
- Floors
- 7
- Residential units
- 13
- Building area
- 20,191 ft²
- Lot area
- 5,400 ft²
- Zoning
- R6
- Community board
- 304
- Council district
- 37
- Block / lot
- 3321 / 28
- Assessed value
- $828,450
- Landmark / historic district
- No
Questions about 1010 Bushwick Avenue
Who owns 1010 Bushwick Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 1010 Bushwick Owner LLC.
Does 1010 Bushwick Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 1010 Bushwick Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1010 Bushwick Avenue built?
City records list 2018 as the year it was built.
How many apartments are in 1010 Bushwick Avenue?
It has 13 residential units and 14 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.