roofy

157 Leonard Street

Brooklyn, NY 11206BBL 3-03032-0018Map

Owner of record: 157 Leonard St LLC

157 Leonard Street is a vacant lot in Brooklyn, 11206. The owner of record is 157 Leonard St LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
2
ECB violations
28
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 2

  • Construction other optional

    Emergency operations following partial structure collapse,stalled for 3 wks due to subsequent lot line wall collapse. final site conditions have not been reached and potential hazards remain. remedy: complete wrk undr permit. get sign-off by 10/4/24. biweekly rpts due until permits are obtained, first due 8/23/24

    Aug 21, 2024

    Dob violation - active
  • Construction other optional

    Emer wrk.partial colaps of 2-sty bldg durng full demo using mechanical equip contrary to permitted job #b00939649. remnant bldg structurally compromised, danger of further collapse. remedy: retain rdp,cs,gc to stabilze/secure/protect public.start by 7/3/24 fulltime rdp&cs supervision. send daily reports

    Jul 2, 2024

    Dob violation - dismissed

ECB violations · 28

  • Class - 2

    Bc 3307.2-pedestrian protection-at the time of my inspection i observed sidewalk work and inadequate pedestrian protection provided on street-walkway 3 feet wide,bariers not joined together-filled up,people wal

    Oct 19, 2026 · Penalty $2,500

    Active
  • Class - 1

    At the time of my inspection i observed 2 stairways going from 1st fl to cellar on exterior at exp#1 approx. 10-12 feet deep-no guardrail system provided as required-stop all work 10 feet from exterior stairway

    Oct 19, 2026 · Penalty $5,000

    Active
  • Class - 2

    At the time of my inspection i observed workers performing work on exterior sidewalk-upon asking competent person for orientation provided for workers-none were done as per competent person/log book-upon asking

    Oct 19, 2026 · Penalty $1,250

    Active
  • Class - 2

    At the time of my inspection i observed inadequate housekeeping through out whole site-cardboards , material, garbage scattered all over floors on every working level(floor)

    Oct 19, 2026 · Penalty $1,250

    Active
  • Class - 2

    At the time of my inspection i observed all fire extinguishers on every floor used as door stopers ,as per fire codes-906.7 and 906.9 fire extinguisher shall be hanging on hanger at least 4 inches from floor

    Oct 19, 2026 · Penalty $625

    Active
  • Class - 2

    Work contrary to ssp-at the time of my inspection observed sws removedfrom site while work not complete on roof/setbacks,ssp does not provide phase of sidewalk work with means and methods of pedestrian protecti

    Oct 19, 2026 · Penalty $1,250

    Active
  • Class - 2

    Work without a permit. at time of inspection, observed mechanical work being performed without ms pw2 filed on dob system., obtain all permits; please submit permit to [email protected]

    Jul 15, 2026 · Penalty $1,250

    Active
  • Class - 1

    At time of inspection, it was determined the general contractor failed to submit the required incident report through the department's electronic portal within three business days for the 06/15/2026 worker inju

    Jul 7, 2026 · Penalty $10,000

    Resolve
  • Class - 1

    Responding to an incident where a worker fell off a ladder while firing proofing the pipes in the ceiling on the 1st floor. inspection revealed that 3 points contact was not maintain during the operation which

    Jun 15, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    Responding to an incident where a worker fell off a ladder while firing proofing the pipes in the ceiling on the 1st floor. upon review of the pre-shift safety meeting it was found that pipe insulation activiti

    Jun 15, 2026 · Penalty $5,000

    Resolve
Show 18 more ↓
  • Class - 1

    Responding to an incident where a worker fell off a ladder while firing proofing the pipes in the ceiling on the 1st floor. inspection revealed that the incident occurred around 12:00 and was not reported to th

    Jun 15, 2026 · Penalty $5,000

    Resolve
  • Class - 2

    Observed construction fence at site with expired permit dated 2-28-2025. (bc -106.8.2)provide valid permit for construction fence on site.

    Mar 28, 2025

    Resolve
  • Class - 2

    Observed closed jobsite where 2 story building is completely demolished. conditions cited in violation #: 39530227x issued 7-2-2024 for cs failure to perform duties mitigated to class 2 since atoi the immediate

    Dec 27, 2024 · Penalty $10,000

    Active
  • Class - 2

    Respondent failed to correct violating condition and file a certificate of correction pursuant to ac 28-204.4 for violation no. 39530226y issued dated 07/02/2024. at time of inspection, i observed inactive clos

    Dec 18, 2024 · Penalty $625

    Resolve
  • Class - 2

    Respondent failed to correct violating condition and file a certificate of correction pursuant to ac 28-204.4 for violation no. 39530227x issued dated 07/02/2024 & violation no. 39531818m issued 08/27/2024. at

    Oct 22, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    Respondent failed to correct violating condition and file a certificate of correction pursuant to ac 28-204.4 for violation no.39530226y issued dated 07/02/2024 & violation 39531817k issued 08/27/2024. at time

    Oct 22, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    Respondent failed to correct the violating condition and file for a certificate of correction pursuant to ac 28-204.4 for violation no. 39530226y issued dated 07/02/2024. at time of inspection, i observed inact

    Aug 27, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    Respondent failed to correct violating condition and file for a certificate of correction pursuant to ac 28-204.4 for violation no. 39530227x issued dated 07/02/2024. at time of inspection, i observed inactive

    Aug 27, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    Mechanical demolition with excavator.@full demo site observe building structure demolition&use of excavator placed on buildings foot with hazards of collapse+blow out conditions&no mechanical demolition equipme

    Jul 2, 2024 · Penalty $6,250

    Resolve
  • Class - 1

    @2story demolition follow up inspection of incident where structure collapsed onto public way observed sites debris generated by demolition operation not store in noncombustible container & combustible debris(w

    Jul 2, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    @2story demolition site incident follow up inspection i observed material(wood) fell on exp#2 neighbor property driveway&buildings structure collapsed onto public way @exp#4& upon research in dob records-bis co

    Jul 2, 2024 · Penalty $5,000

    Resolve
  • Class - 1

    @2story demo incident site observe super on permit fail to perform duties&ensure safe demo operations-no mechanical demo permit,building glass not removed prior to demo,structure collapsed on to publicway+mater

    Jul 2, 2024 · Penalty $10,000

    Resolve
  • Class - 1

    Contractor was performing demo of structure with an excavator on site. operator hit wall on exposure #4 causing debri to fall over unto street level. contractor has no sequence for demo work on site. a section

    Jul 1, 2024 · Penalty $25,000

    Resolve
  • Class - 1

    At time of inspection excavator on site performing demo with no plans for demo operation indicating sequence or mechanical equipment approved by dob to be used during operations., comply with code; provide demo

    Jul 1, 2024 · Penalty $25,000

    Resolve
  • Class - 2

    Bc- 3307.2.1 observed manlift stored on street exp# 1 with no dot permit obtain dot permit

    Jun 12, 2024 · Penalty $625

    Resolve
  • Class - 2

    Failure to comply with manufacturer specifications.observed jersey barrior installed around manlift stored on street exp #1.jersey barrier not interlocked & water filled as per specification of manufacture.reme

    Jun 12, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    At the time of inspection active jobsite i observed sidewalk shed erect at exposure#2 and 4 for demo operation installed contrary to approved plans there is missing debris netting including 42" parapet panels w

    Jun 11, 2024 · Penalty $6,250

    Resolve
  • Class - 2

    At the time of inspection active jobsite while responding to a complaint. i observed fallen debris on adjacent property cars and yard at exposure #2 from the construction site located at 157 leonard street, cre

    Jun 11, 2024 · Penalty $5,000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Vacant lot (V0)
Year built
—
Floors
—
Residential units
—
Building area
—
Lot area
2,350 ft²
Zoning
R6B
Community board
301
Council district
34
Block / lot
3032 / 18
Assessed value
$5,383
Landmark / historic district
No

Questions about 157 Leonard Street

Who owns 157 Leonard Street?

The owner of record in NYC Department of City Planning PLUTO data is 157 Leonard St LLC.

Does 157 Leonard Street have violations?

NYC HPD has no housing violations on record for this property.

Is 157 Leonard Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.