roofy

87 Herbert Street

Brooklyn, NY 11222BBL 3-02829-0039Map

Owner of record: 87 Herbert Street, LLC

87 Herbert Street is a walk-up apartment building built in 2024 in Brooklyn, 11222. It has 7 residential units across 4 floors. The owner of record is 87 Herbert Street, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
1
ECB violations
20
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 1

  • Construction other optional

    Emerg wrk,exp#2 cornice destablzed.during pre-demo asbestos.abatement wrk relatd2full demo(job#b00867598)unsafe conditn present,significant overhead hazard present,potential for cornice collapse. remedy: comply w code,imeditly retain rdp,cs&demo endorsd gc 2 establish collpse zone stablz cornc,file in2days,start wrk by 6/9/23@10am

    Jun 8, 2023

    Dob violation - dismissed

ECB violations · 20

  • Class - 2

    /work contrary to ssp/code-observed pump jacks installed at exp#4 adj property roof not on ssp,overhead protection extended only approx.6'-8' from adj property as per ssp shall be +/-16.6' long,adj property onl

    Jul 29, 2026

    Resolve
  • Class - 2

    At the time of my inspection observed supported scaffold installed at exp#1/2 on top of sws,2-pump jacks set ups installed at exp#4 adj property roof-upon asking for load imposed letter(bc 3314.3.4)-none were p

    Jul 29, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain/display on site documents required by bc chapter 33. at the time of inspection of an active construction 4 story new building. 1 observed steel panel staircase in place at exp 4 with 2 landi

    Jun 24, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection on active job site currently at roof level, i observed that there aren't no numbers and stair designation on floors at interior stairs leading up to the interior of building no s

    May 27, 2026

    Resolve
  • Class - 2

    At the time of inspection on an active job site currently at roof level, i observed that no smoking signs were posted on wall at each floor as per bc required .

    May 27, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection on an active job site , i observed temporary shoring supporting cold form steel work decking on each floor throughout building . when i asked contractors on site for design drawings t

    May 27, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of my inspection observed construction fence at exp#1 and#2 not maintain-big amount of posters not completley ripped from fence-not painted hunter green- ,missing viewing panel cover,grafiti

    Mar 3, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Observed active jobsite w/ multiple non-construction related signage posted on construction fence at expo #1 and #2. provide and maintain construction fence at exposure 1 and 2 as per code.

    Jul 15, 2025 · Penalty $1,030

    Resolve
  • Class - 1

    Observed structural steel modified/ torched cuts and connections for structural soe & support of formwork. no p.e. approved drawings for modification of structural steel available/ provided for field fabricati

    Jan 8, 2025

    Resolve
  • Class - 2

    Observed multiple cracks on the sidewalk at exp.#1&2 creating a trip and fall hazard for pedestrians commuting.maintain sidewalk in code compliance.

    Jan 8, 2025

    Resolve
Show 10 more ↓
  • Class - 2

    Failure to maintain/display on site documents required by bc chapter 33. as noted at time of inspection of my inspection observed formwork in place at foundation level for foundation wall on requesting design f

    Jan 8, 2025

    Resolve
  • Class - 1

    Observed active jobsite at excavation phase, worker jan skowron w/ supervisor sst card stated that was the designated competent person, no construction superintendent #30652 log book to verify designation & dis

    Jan 8, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to obtain requested design professional evaluation prior to using existing structure to support formwork loads-as noted at time of my inspection at above jobsite observed at foundation level at exposure

    Jan 8, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to provide adequate inspection progress for tr1. as noted at time of inspection on active construction site. 4 stories new building working in progress on foundation phase. i observed at foundation leve

    Jan 8, 2025 · Penalty $1,250

    Resolve
  • Class - 1

    Observed soldier's piles installed underneath rakers along exp.#1 & 2 for soe support, piles not connected to the raker. no approved plans available to verify structural field conditions. stop all soe work.prov

    Jan 8, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Observed active support of the excavation construction site upon requesting for pre-construction survey, optical and vibrating monitoring none were provided / on site.stop all soe workprovide pre-construction s

    Jan 8, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Observed an active construction site with inadequate multiple fire extinguisher which all of them are missing annual inspection/service tags.maintain fire extinguishers per the nyc fire code.

    Jan 8, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Observed: site closed no ongoing construction activity upon exterior inspection noted: fence has been erected on exposure 1 and not maintained as per code observing signs not refering to construction work pos

    Nov 21, 2024 · Penalty $1,000

    Resolve
  • Class - 3

    Building is located in general residence district. observed commercial equipment (tar truck) stored at exposure#2 driveway., discontinue illegal use

    Sep 29, 2020 · Penalty $500

    Resolve
  • Class - 2

    Illegal use in a residntial district.at time of inspection observed anattached garage approx.25x50 feet at exposures #2&3.respondent was storing constructiion material up on the roof,materials consisted of

    Nov 8, 2017 · Penalty $800

    Resolve

Complaints

  • Appliance

    Electric/gas range

    Apr 16, 2023 · Apt 1RR

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
2024
Floors
4
Residential units
7
Building area
4,432 ft²
Lot area
2,500 ft²
Zoning
R6B
Community board
301
Council district
34
Block / lot
2829 / 39
Assessed value
$247,950
Landmark / historic district
No

Questions about 87 Herbert Street

Who owns 87 Herbert Street?

The owner of record in NYC Department of City Planning PLUTO data is 87 Herbert Street, LLC.

Does 87 Herbert Street have violations?

NYC HPD has no housing violations on record for this property.

Is 87 Herbert Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 87 Herbert Street built?

City records list 2024 as the year it was built.

How many apartments are in 87 Herbert Street?

It has 7 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.