roofy

152 Meserole Avenue

Brooklyn, NY 11222BBL 3-02622-0008Map

Owner of record: 152 Meserole Ave LLC

152 Meserole Avenue is a walk-up apartment building built in 2025 in Brooklyn, 11222. It has 8 residential units across 5 floors. The owner of record is 152 Meserole Ave LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
9
ECB violations
25
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 9

  • Construction other optional

    Borough commissioner has ordered all work stopped under permit #b08026584-s4 on 5/11/26, contractor withdrawal, due to contractor withdrawal.

    Jun 17, 2026

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1993

    Dob violation - dismissed

ECB violations · 25

  • Class - 2

    Responding to a complaint observed: sidewalk shed installed at expo# 1-2. no underside lighting inoperable light bulbs, failure to maintain as per code 3307.6.4.8 become an unsafe and hazardous condition for pe

    Apr 28, 2026 · Penalty $2,400

    Active
  • Class - 2

    Upon inspection i observed pipe scaffold installed at expos 2 approx. 42ft high in a unsafe manner contrary to code 3314.1 . multiple locations on the pipe scaffold missing the required stacking pins. possible

    Apr 23, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Upon inspection i observed pipe scaffold installed approx. 42ft tall at expos 2 and a electric pully system on 5th floor. upon request to see documents to be kept on site none was provided at the time of my ins

    Apr 23, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    Upon inspection i observed pipe scaffold installed in a unsafe manner at expos 2 approx. 42ft in height. scaffold was missing guardrails at multiple working deck locations contrary to code. not installing guard

    Apr 23, 2026 · Penalty $5,000

    Resolve
  • Class - 1

    Upon inspection i observed pipe scaffold installed in a unsafe manner at expos 2 approx. 42ft in height. scaffold was missing toe boards at multiple working deck locations contrary to code. not installing toe b

    Apr 23, 2026 · Penalty $5,000

    Resolve
  • Class - 2

    I observed a sidewalk shed installed at expos 1&2 contrary to approved drawings. shed not installed tight to adjoining properties at expos 1&2. missing cross brace at expos 1. mudsill not secured to beam at exp

    Apr 23, 2026 · Penalty $1,250

    Active
  • Class - 2

    Upon inspection i observed a fence installed at expos 1&2 with an inadequate and missing fence project info panel. expos 2 info panel was not 36.5in tall and 55in wide contrary to code 3301.9.1.4. primary permi

    Apr 23, 2026 · Penalty $1,250

    Active
  • Class - 2

    Upon inspection i observed a sidewalk shed installed at expos 1&2 with not sidewalk shed project info panel installed contrary to code 3301.9.2 sidewalk shed parapet information panel. where a sidewalk shed is

    Apr 23, 2026 · Penalty $1,250

    Active
  • Class - 2

    Upon inspection i observed a fence installed at expos 1&2 not constructed or maintained according to code. protruding objects (wood, screws). damaged wood panels that need to be replaced. not fully painted hunt

    Apr 23, 2026 · Penalty $1,000

    Resolve
  • Class - 1

    Upon inspection of an active 5 story nb i observed no handrails provided at steps at the building entry on the 1st floor expos 2 and no handrails provided in the basement and stairs leading to the basement.

    Apr 23, 2026 · Penalty $2,500

    Active
Show 15 more ↓
  • Class - 1

    Upon inspection of an active 5 story nb i observed multiple floors with missing and inadequate fire extinguishers. no extinguishers provided on 4,5, roof and basement. extinguishers on 2 & 3 were not off the gr

    Apr 23, 2026 · Penalty $1,250

    Active
  • Class - 2

    Upon inspection of a active 5 story nb construction site i observed no "no smoking signs provided/installed on the interior of the superstructure on any floors contrary to code 3303.7.3

    Apr 23, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    Observed sidewalk shed installed around the jobsite perimeter was constructed contrary to the approved design. review of the approved drawings revealed specifically, the required kickers on the vertical members

    Jan 4, 2026

    Resolve
  • Class - 2

    Inactive jobsite, observed construction fence installed around jobsite perimeter seen in inadequate condition not maintained as per code requirement, after review of bis & the department of buildings (dob) syst

    Jan 4, 2026 · Penalty $6,250

    Active
  • Class - 2

    At the time of inspection, i observed construction fence around jobsite perimeter not maintained in accordance with bc 3307.7. panels in inadequate condition covered with multiple advertising posters unrelated

    Jan 4, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection upon reviewing previous complaint# 3a24381 issued 08/05/2025. gc fail to comply with the commissioner's order and no corrective measures on record for violation# 39543281j.

    Oct 22, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    Failure to file certificate of correction with the dob for violation# 39543292p issued 08/05/2025 and no corrective measures on record.

    Sep 29, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    Responding a complaint observed: sidewalk shed in place at exposure# 1-2 with inoperable light bulbs underneath of sidewalk shed contrary to bc 3307.6.4.8 creating a potential unsafe environment condition for p

    Sep 9, 2025 · Penalty $2,400

    Resolve
  • Class - 1

    3305.1.1- observed make-shift shoring for the support of the 2-story decks on disturbed soil while active operations on both decks & loaded w/ materials. no design drawings, approved plans, pe shop drawings for

    Aug 5, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Observed jobsite at the superstructure phase, upon reviewing the department records, permit b08026584-i1-nb was not issued, only in conjunction permits for se, fo & st. stop all work on the entire site under ap

    Aug 5, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    Observed formwork being performed @ expo 3 on top of ohp for adjacent property & jobsite accessible by residents, w/out a construction fence, no neighbor agreement for use adjacent property, no caz or means & m

    Aug 5, 2025 · Penalty $12,500

    Resolve
  • Class - 1

    3301.6- observed sidewalk shed installed @ exposures 1 & 4, with deck being used for staging area and loaded with materials & equipment as storage zone, not reflected on sidewalk shed plans. stop all use of the

    Aug 5, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    3301.13.16- observed active jobsite w/out active permit, accessible by residents adjacent property, unsafe working operations/installation of temporary formwork & material, multiple make-shift temporary structu

    Aug 5, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Full demolition of 1 story garage .observed at time of inspection . site closed no ongoing construction activity also noted fence has been erected on exposure 1,2 upon review on dob now and bis this permit has

    Aug 27, 2024

    Resolve
  • Non-hazardous

    Clean gas burners-low water cut off blowdown valve leaking on gas tain install emergency shut of a switch at stairway entrance. dirty boiler room and not a storage room.

    Feb 21, 1989

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
2025
Floors
5
Residential units
8
Building area
6,428 ft²
Lot area
1,875 ft²
Zoning
R7A
Community board
301
Council district
33
Block / lot
2622 / 8
Assessed value
$52,200
Landmark / historic district
No

Questions about 152 Meserole Avenue

Who owns 152 Meserole Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 152 Meserole Ave LLC.

Does 152 Meserole Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 152 Meserole Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 152 Meserole Avenue built?

City records list 2025 as the year it was built.

How many apartments are in 152 Meserole Avenue?

It has 8 residential units.