50 South 2 Street
Brooklyn, NY 11249BBL 3-02415-0016Map
Owner of record: 50 South 2nd Owner, LLC
50 South 2 Street is a garage / gas station in Brooklyn, 11249. The owner of record is 50 South 2nd Owner, LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 17
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 17
- Class - 2
Failure to provide special inspection of concrete placement tr1. as noted at the time of inspection of an active jobsite, proposed 7 story new building, at 3rd floor level; i observed there was no tr1 special a
Aug 13, 2026 · Penalty $1,250
Active - Class - 1
@7story new major building site w/construction superintendent rafael fernandez cs#029162 on job record,upon review the super log it was revealed rafael had been performing duty while on additional jobs@308 14 s
Jul 29, 2026 · Penalty $5,000
Active - Class - 2
The r-value of the installed exterior walls outboard insulation at exposure # 2 and #4 is r-value 10 with thickness 2" contrary with the approved dob en drawing and architectural drawing that indicate r-value 1
Jul 21, 2026 · Penalty $1,250
Active - Class - 2
As per violation# 39550962k issued 02-25-2026 certificate of correction were disapproved and no corrective measures on record.
Jul 6, 2026 · Penalty $1,250
Resolve - Class - 2
Observed a construction fence installed, protruding onto the public sidewalk by an active garage, creating a blind spot hazard for pedestrians passing by the driveway b.c 3307.2.6. cars are coming out the garag
May 23, 2026 · Penalty $1,000
Resolve - Class - 2
At the time of inspection of a class #1 summons, i observed jobsite padlock with no construction activities and failure to comply for certificate of correction in the department system. comply with code and fi
May 20, 2026
Resolve - Class - 2
Gc fail to file certificate of correction with the dob no corrective measures on record for violation# 39550963m issued 02-25-2026
May 1, 2026 · Penalty $1,250
Resolve - Class - 2
Gc fail to file certificate of correction with the dob no corrective measures on record for violation# 39550962k issued 02-25-2026.
May 1, 2026 · Penalty $1,250
Resolve - Class - 2
I observed a sidewalk shed in place. no high visibility marking on vertical members at exp#1 within 7 feet of a driveway at adjoining property in violation of bc 3307.6.4.5
Apr 30, 2026 · Penalty $2,400
Resolve - Class - 2
I observed sidewalk shed erected and in place at exposure #1 missing parapet information panel in violation of bc3301.9.2
Apr 30, 2026 · Penalty $1,250
Resolve
Show 7 more ↓
- Class - 1
A proposed seven-story building, the superintendent failed to perform required duties, resulting in multiple violations. no overhead protection was provided at exp# 3 and 4, guardrail systems from the first to
Mar 16, 2026 · Penalty $10,000
Resolve - Class - 1
At the time of my inspection of a 7 story new building at 2nd floor decking level, i observed at exposure #4 adjacent building windows were not protected. failure to provide and maintain adequate window protect
Feb 25, 2026 · Penalty $5,000
Resolve - Class - 1
At the time of my inspection of a 7 story new building at 2nd floor decking level, upon review of the department record it reveal that there were no site safety manager or coordinator designate for a 7 story ne
Feb 25, 2026 · Penalty $10,000
Resolve - Class - 1
At the time of my inspection of a 7 story new building at 2nd floor decking level, upon review of the department record it reveal that there were no new building and structural permit issued. failure to obtain
Feb 25, 2026 · Penalty $2,500
Resolve - Class - 2
At the time of inspection i observed concrete operation in progress at the 2nd floor level approximately 8ft above fence of adjacent properties parking lot at exposure#3 right and left corners of rear yards, w
Feb 19, 2026 · Penalty $5,000
Resolve - Class - 2
At the time of inspection active site, upon reviewing approved site plan, i observed overhead protection and netting to be installed at exposure#3 in properties rear yard prior to installation of 2nd floor leve
Feb 19, 2026 · Penalty $1,250
Resolve - Class - 2
At the time of inspection active jobsite at the 2nd floor level with concrete operation in progress, i observed concrete pump machine stored adjacent to shed at exposure#1 not provided with a 4ft plywood barrie
Feb 19, 2026 · Penalty $2,500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Garage / gas station (G7)
- Year built
- —
- Floors
- —
- Residential units
- —
- Building area
- —
- Lot area
- 5,000 ft²
- Zoning
- M1-4/R6A
- Community board
- 301
- Council district
- 33
- Block / lot
- 2415 / 16
- Assessed value
- $444,150
- Landmark / historic district
- No
Questions about 50 South 2 Street
Who owns 50 South 2 Street?
The owner of record in NYC Department of City Planning PLUTO data is 50 South 2nd Owner, LLC.
Does 50 South 2 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 50 South 2 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.