111 North 10 Street
Brooklyn, NY 11249BBL 3-02296-7501Map
Owner of record: The 111 North 10th Street Condominium
111 North 10 Street is a condominium built in 1928 in Brooklyn, 11249. It has 39 residential units across 6 floors. The owner of record is The 111 North 10th Street Condominium. HPD has recorded 4 housing violations here, most recently on February 2, 2026.
- HPD violations
- 4
- DOB violations
- 29
- ECB violations
- 32
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 4
- ANon-hazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 2nd room from east located at apt 5c, 5th story, 3rd apartment from west at north
Feb 2, 2026 · Apt 5C
Closed — Violation dismissed - BHazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the 2nd room from east located at apt 5c, 5th story, 3rd apartment from west at north
Feb 2, 2026 · Apt 5C
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 5c, 5th story, 3rd apartment from west at north
Feb 2, 2026 · Apt 5C
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 5c, 5th story, 3rd apartment from west at north
Feb 2, 2026 · Apt 5C
Closed — Violation dismissed
DOB building violations · 29
- Plumbing none
Based on lic# 001343 being inactive, stop all plumbing work under job #320882693 immediately.
Jun 23, 2025
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 22, 2025
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 26, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 30, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 29, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 15, 2024
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2022
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2021
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2020
Dob violation - dismissed
Show 19 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2020
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2020
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2018)
Mar 18, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 17, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 11, 2019
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)
Mar 27, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 1, 2018
Dob violation - resolved - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2016
Feb 16, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 27, 2017
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 1, 2016
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
May 31, 1994
Dob violation - dismissed - Construction other optional
C-construction other optional
May 14, 1992
Dob violation - dismissed - Zoning none
Z-zoning none
May 7, 1992
Dob violation - dismissed
ECB violations · 32
- Class - 2
Observed no construction activities no workers on site. failure to file acceptable certificate of corrections coc for class 1 violation # 39534496m issued on 11-18-2024 for 2 workers on job site without sst ca
Jun 4, 2025 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code-compliant manner. at time of inspection, observed water leaks coming from the ceiling, vertical and horizontal cracks at various locations in unit 301., repair and/or replac
May 27, 2025 · Penalty $1,250
Resolve - Class - 2
Observed violation# 39534496m for workers with no sst cards on 11/19/2024, upon review the department records ( bis & dob now) observed no compliance recorded to file a certificate of correction, certificate di
Apr 8, 2025 · Penalty $1,250
Resolve - Class - 2
Bc 3307.2 failure to comply with dot regulations. observed active lifting operations using boom lift with sidewalk fully enclosed for pedestrians, upon request for dot permit for boom lift and sidewalk closure,
Apr 8, 2025 · Penalty $2,500
Resolve - Class - 2
Bc 3307.5 flagperson. observed active lifting operations by boom lift and sidewalk shed is fully enclosed. observed no flaggers were provided. one flagperson were standing on the opposite sidewalk where he is n
Apr 8, 2025 · Penalty $2,500
Resolve - Class - 1
Bc 3301.13.5 alternate construction superintendent. observed active site for lifting operations and other activities, upon request from pm for competent person or construction superintendent, none of them were
Apr 8, 2025
Resolve - Class - 2
Failure to file acceptable certificate of corrections for class 1 violation #: 39534496m issued on 11-18-2024 for 2 workers on site without sst cards. coc filed on 12-11-2024, disapproved on 12-24-2024.file acc
Jan 17, 2025 · Penalty $1,250
Resolve - Class - 2
Convert existing commercial space 1st floor to a health and fitness establishment . observed atoi active site cp present upon inspection on front sws was noted it has been erected contrary to plans , missing ho
Nov 18, 2024
Resolve - Class - 2
Convert existing commercial space 1st floor to a health and fitness establishment . observed atoi active site cp present upon inspection was checked orientation log bock and noted workers isaac and jaime morale
Nov 18, 2024 · Penalty $1,250
Resolve - Class - 2
Convert existing commercial space 1st floor to a health and fitness establishment . observed atoi active site cp present upon inspection was noted materials has been storage on street ,contrary to building code
Nov 18, 2024 · Penalty $2,500
Resolve
Show 22 more ↓
- Class - 1
Convert existing commercial space 1st floor to a health and fitness establishment . observed atoi active site cp present upon inspection was requested a sst card to isaac and julio morales, both say does not ha
Nov 18, 2024 · Penalty $10,000
Resolve - Class - 2
Convert existing commercial space 1st floor to a health and fitness establishment . observed atoi active site cp present upon inspection was noted several issues like, inadequate orientation log book , workers
Nov 18, 2024 · Penalty $5,000
Resolve - Class - 1
Failure to provide flag person while lifting materials from roof using boom truck parked on berry street for emergency work as per bc 3307.4.3, bc 3307.4.4 and bc 3307.5. stop all boom truck operations. provide
Mar 26, 2024 · Penalty $5,000
Resolve - Class - 1
Failure to provide sidewalk shed where required; noted: observed elevator shaft being built is approx. 50ft in height above roof level & the perpendicular distance from the new structure to the sidewalk is only
Mar 13, 2024
Resolve - Class - 1
Observed temporary supported scaffolding erected inside of elevator shaft & roof level is approx. 50 ft or more in height & no permit on file as of 03-13-24. stop all work at elevator shaft & building exterior.
Mar 13, 2024
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments; note: observed the approved plans for elevator shaft under application # b00869568/b00981919 does not have a detail section s
Mar 13, 2024
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guard rails; noted: observed missing section of guard rails at roof top leading edge., provide guard rails
Mar 13, 2024
Resolve - Class - 2
Observed permitted electrical works in progress on ground floor commercial space and storage materials & tools inadequate manner. no guardrail or separation provided area & material storage. upper floors tenant
Sep 27, 2023
Resolve - Class - 1
Work without permit atoi observed in an occupied mixed use building workers installing new bx cable without any active permit posted at the commercial site. stop all electrical work at ground floor commercial s
Aug 16, 2023
Resolve - Class - 2
At the time of inspection, observed interior demolition site with excavation. upon request no plan nor excavation work details such as depth, area, support, monitoring and etc.. was provided. g.c failed to pro
Jul 5, 2023
Resolve - Class - 1
Class 2: provide keys to access elevator machine room., class 1: no door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which
Apr 20, 2022 · Penalty $1,250
Resolve - Class - 2
Provide keys to access roof., provide keys to access elevator machine room.
Apr 20, 2022
Resolve - Class - 2
Failure to maintain building in a code-compliant manner. note: brick facade at (exp #1) front facade brick is cracked, loose and defective. there is also cracks in brickwork at exp #4 wall. rem: repair and/or r
Oct 13, 2018
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirement.at the time of inspection the contractor allowed piles of debris to collect throughout the 1st flr of the site.the cellar level was unreachable
Oct 11, 2017 · Penalty $400
Resolve - Class - 1
Bc3303.8/failure to provide standpipe in state of readiness as required by code.at the time of inspection,the contractor did not correctly identify the standpipe within the structure,with the appropriate red ma
Oct 11, 2017 · Penalty $400
Resolve - Class - 2
Failure to provide approved/accepted plans at jobsite at the time of inspection.at the time of inspection the contractor did not provide anydob approved plans.rem:provide plans.
Oct 11, 2017 · Penalty $250
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperations.at the time of inspection,the contractor allowed several violating conditions to take place.due to poor lighting and excessive am
Oct 11, 2017 · Penalty $5,000
Resolve - Class - 2
08x10 repair door zone lock.
Aug 18, 2016
Resolve - Class - 1
Work w/o a permit. observed new sprinkler system installed throughout entire bldg. no approved permit on file. full swo. *photo taken* remedy: obtain permit.
Oct 9, 2013 · Penalty $800
Resolve - Class - 1
Sec. bc 905.3.1 & nfpa 14.3.3.9. required standpipe system not installed. system was changed from a wet system to a dry system w/no approvalfrom dob and fdny. remedy: install standpipe system.
Oct 9, 2013 · Penalty $1,600
Resolve - Class - 1
Work w/o a permit. based on physical observation of standpipe system; standpipe system was changed from wet system to a dry standpipe systemw/no approval from dob or fdny. full swo. remedy: obtain permit.
Oct 9, 2013 · Penalty $1,600
Resolve - Class - 1
Failure to maintain building in code compliant manner:lack of a systemof automatic sprinklers where required. while building under construction a section of sprinkler pipe was removed and plugged off.local law
Jul 12, 2013 · Penalty $1,000
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RM)
- Year built
- 1928
- Floors
- 6
- Residential units
- 39
- Building area
- 129,919 ft²
- Lot area
- 45,000 ft²
- Zoning
- M1-2/R6A
- Community board
- 301
- Council district
- 33
- Block / lot
- 2296 / 7501
- Assessed value
- $12,964,382
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 111 North 10 Street
Who owns 111 North 10 Street?
The owner of record in NYC Department of City Planning PLUTO data is The 111 North 10th Street Condominium.
Does 111 North 10 Street have violations?
Yes. NYC HPD has recorded 4 housing violations at this property.
Is 111 North 10 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 111 North 10 Street built?
City records list 1928 as the year it was built.
How many apartments are in 111 North 10 Street?
It has 39 residential units and 41 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.