49 Lorimer Street
Brooklyn, NY 11206BBL 3-02240-7504Map
Owner of record: Unavailable Owner
49 Lorimer Street is a condominium built in 1995 in Brooklyn, 11206. It has 4 residential units across 4 floors. The owner of record is Unavailable Owner. HPD has recorded 27 housing violations here, most recently on May 5, 2026. 3 of the 27 most recent violations are still open.
- HPD violations
- 27
- DOB violations
- 0
- ECB violations
- 24
- HPD complaints
- 0
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 27
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
May 5, 2026
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Jun 10, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 10, 2024
Closed — Violation dismissed - CImmediately hazardous
Remove the illegal fastening ....key operated lock on interior of the building entrance door , 1st story
Dec 13, 2023
Open — Not complied with - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 23, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 7, 2022
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Feb 25, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Feb 25, 2022
Closed — Violation dismissed - ANon-hazardous
Trace and repair the source and abate the visible mold condition... ceiling (approx 6 sqft) in the public hall at 4th story
Dec 29, 2021
Closed — Violation closed - BHazardous
Replace with new the missing fire door at boiler room in the cellar
Dec 29, 2021
Closed — Violation closed
Show 17 more ↓
- BHazardous
Properly repair with similar material the broken or defective fire retardant ceiling in the public hall at 4th story
Dec 29, 2021
Closed — Violation closed - BHazardous
Repair the roof so that it will not leak ceiling in the public hall at 4th story
Dec 29, 2021
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department ceiling in the public hall at 4th story
Dec 29, 2021
Closed — Violation closed - BHazardous
Remove all encumbrances consisting of household items in the public stairs at 4th and 3rd stories
Dec 29, 2021
Open — Not complied with - BHazardous
Trace and repair the source and abate the visible mold condition... ceiling (approx 6 sqft) in the public hall at 4th story original violation 14759688 issued 29-dec-21 has been upgraded to class b per administrative code §27-2017.3a(3)(a) or (b).
Dec 29, 2021
Open — Defect letter issued - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 9, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Apr 9, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 30, 2019
Closed — Violation dismissed - BHazardous
Repair or replace the carbon monoxide detecting device(s). ''defective'' in the entire apartment located at apt 1, 1st story, apartment at west
Oct 24, 2019 · Apt 1
Closed — Violation closed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 18, 2018
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 10, 2016
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 13, 2015
Closed — Violation dismissed - BHazardous
Section 185, 240 m/d law properly fire retard in accordance with the rules and regulations of this department the cellar ceiling ... at boiler room
Oct 20, 2014
Closed — Violation closed - BHazardous
Repair the broken or defective connection at exposed sewer line at ceiilng at boiler room
Oct 20, 2014
Closed — Violation closed - BHazardous
Repair the flushing apparatus and maintain same so as to flush effectively the water closet ... in the 2nd bathroom from north located at apt 1, 1st story, apartment at west
Oct 20, 2014 · Apt 1
Closed — Violation closed - BHazardous
Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 100 watts required lights not on.
Dec 3, 2007
Closed — Violation dismissed - BHazardous
Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 100 watts minimum required
May 9, 1999
Closed — Violation dismissed
DOB building violations · 0
No DOB violations on record
ECB violations · 24
- Non-hazardous
Building does not comply with quality housing program as per sections 28-12 and 28-22 of the zoning resolution in that there are no double glazed windows nor required plantings. file plans to legalize.
Dec 13, 1999 · Penalty $480
Active - Non-hazardous
Structural defects which violate refrence standard rs10-5b were observed , in that (i) no strap bracing for "c" joists present . (ii) anchorage between joists and bearing or non-bearing wall was not provided .
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Fire stopping at party walls of building is not provided ,contrary to requiremqnts of section 27-332 of the nuilding code. remedy: file plans to legalize if feasible and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Parapet on exterior wall of building is not provided at the roof of the fourth floor as per section 27-333 of the buioding code. remedy: file plans to legalize if feasible and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Handicap access to the buildinf is not provided as per section 27-292.5(a) of the building code. file plans to legalize if feasible and conform to code.
Dec 13, 1999 · Penalty $500
Active - Non-hazardous
Stair enclosure does not comply with the required fire resistance rating, in that the building is built as a four -story ,occuoancy group j-2 ,which requires a two hour fire rated enclosure as per -section 27-3
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Bulkhead of fire resistant consteuction meting the requirements of subchapter five of the building code is not provided as per 27-375(k) (i)remedy: file plans to legalize if feasible . and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Skylight and ventilators for stair enclosure are not provided as per section 27-375 (i) (4-c of the building code. remedy: file plans to legalize if feasible and conform to code
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Roof access in missing in that buildings more than three stones or forty feet high shall have an access to the roof by at least one interior stair as per section 27-375 (k) of the building. file plans to leg
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Existing apartment doors open directly into stair enclosure contrary to section 27-375(j) remedy: file plans to legalize if feasible and conform to code
Dec 13, 1999 · Penalty $400
Active
Show 14 more ↓
- Hazardous
Second means of egress for four story building . construction class 2b is not provided as per section 27-366 of the building code: remedy: file plans to legalize if feasible and cinform to code
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Wood stair between cellar and first floor is not permitted as per section 27-375(h) remedy: make stair of non- combustible material as required by code and obtain dob inspection
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Wood stair between cellar and first floor is not permitted ,as per section 27-375 (h) remedy: make stair of non-combustible material , as required by code , and obtain d,o,b inspection
Dec 13, 1999 · Penalty $400
Active - Hazardous
Second means of egress for four -story building ,construction class 2b , is not provided as per section 27-366 of the building code. remedy: file plans to legalize if feasible and conform to code
Dec 13, 1999 · Penalty $480
Active - Non-hazardous
Existing apartment doors open directly into stair enclosur contrary to section 27-375 (j) . remedy: file plans to legalize if feasible and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Roof access is missing in that buildings more than three stories or forty feet high shall have an accedd to the roof by at least on interior stair as per section 27-375 (k) of the building code . remedy: file p
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Skylight and ventilators for stair enclosure are not provided as per section 27-375 (i) (4)(c) of the building code. remedy: file plans to legalize if feasible and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Bulkhead of fire resistant construction meeting the requirements of subchapter five of the building code is not provided as per 27-375 (k)(1. remedy: file plans to legalize if feasible and conform to code
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Stair enclosure does not comply with the required fire resistance rating , in that the building is built as a four - story , occupancy group j-2, which requires a two-hour fire rated enclosure as per section 27
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Handicap access to the building is not provided as per section 27-292.5(a) of the building code. remedy: file plans to legalize if feasible and conform to code
Dec 13, 1999 · Penalty $500
Active - Non-hazardous
Parapet on exterior wall of building is not provided at the roof of the fourth floor as per section 27-333 of the building code. remedy: file plans to legalize if feasible and conform to code. remedy: file plan
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Fire stopping at party walls of building is not provided , contrary to requirements of section 27-332 of the building code. remedy; file plans to legalize if possible and conform to code.
Dec 13, 1999 · Penalty $400
Active - Non-hazardous
Building does not comply with quality housing program as per section 28-12 and 28-22 of the zoning resolution in that there are no double- glazed windows nor required planings. remedy: file plans to legalize a
Dec 13, 1999 · Penalty $480
Active - Non-hazardous
Structural defects which violate refrence standard rs-10-5b were observed , in that: 1- no strap bracing for 'c" joists present 2- anchorage between joist and bearing or non- bearing wall was not provided , sti
Dec 13, 1999 · Penalty $400
Active
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (R1)
- Year built
- 1995
- Floors
- 4
- Residential units
- 4
- Building area
- 5,022 ft²
- Lot area
- 2,708 ft²
- Zoning
- R6
- Community board
- 301
- Council district
- 33
- Block / lot
- 2240 / 7504
- Assessed value
- $383,853
- Landmark / historic district
- No
HPD registration #377558, last renewed Oct 10, 2025.
Questions about 49 Lorimer Street
Who owns 49 Lorimer Street?
The owner of record in NYC Department of City Planning PLUTO data is Unavailable Owner.
Does 49 Lorimer Street have violations?
Yes. NYC HPD has recorded 27 housing violations at this property.
Is 49 Lorimer Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 49 Lorimer Street built?
City records list 1995 as the year it was built.
How many apartments are in 49 Lorimer Street?
It has 4 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.